Fisher & Paykel PROFESSIONAL RGV3305L Скачать руководство пользователя страница 20

20

INSTALLING THE ANTI-TIP BRACKET

Once installed

Check for proper installation of the range and Anti-tip bracket by grasping the back of the range 
and carefully attempting to tilt it forward.

All ranges must have an anti-tip device correctly installed as per the following instructions. If you 
pull the range out from the wall for any reason, make sure that the device is properly engaged 
when you push the range back against the wall. If it is not, there is a risk of the range tipping over 
and causing injury if you or a child stand, sit or lean on an open oven door.

Instructions are provided for wood and concrete floors. Any other type of construction may 
require special installation techniques as deemed necessary to provide adequate fastening of the 
Anti-tip bracket to the floor and wall. The use of this bracket does not preclude tipping of the 
range when not properly installed.

Concrete or cement substrate

Locate the bracket as shown. 

Using the bracket as a template, drill 
(x2) 5/16" diameter pilot holes in the 
center of the 

larger holes

 to a depth of 

at least 1 3/4". 

Place the sleeve anchors into the 
holes and use a hammer to tap them  
all the way in. 

Tighten the nuts on the sleeve anchors to 
fasten the bracket securely to the floor. 

Wood substrate

Place the bracket against the back wall, 
into the right rear corner where  
the range is to be located. Leave a 1/2" 
(13mm) gap between the wall (or side of 
range) and the bracket, as shown. 

Drill 1/8" diameter pilot holes in the center 
of the 

two small holes

. A nail or awl may 

be used if a drill is not available. 

Fasten the bracket securely to the 
floor and wall. 

 WARNING!

To reduce the risk of tipping the appliance, it 

must be secured by properly installed anti-tip 

device packed with the appliance.

•  A child or adult can tip the range and be killed.
•  Install the anti-tip device to the structure by fastening 

the supplied bracket to the floor and wall following 

the instructions for installing the anti-tip device.

•  Engage the anti-tip device. 
•  Re-engage the anti-tip device if the range is moved.

Concrete

Wood

1/2" (13mm)

Right rear foot 

slides under bracket

Locating the bracket

Securing the range

Содержание PROFESSIONAL RGV3305L

Страница 1: ...RDV3 RHV3 RIV3 models PROFESSIONAL RANGE INSTALLATION GUIDE US CA...

Страница 2: ...any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier cal...

Страница 3: ...may result in damage or personal injury Proper equipment and adequate manpower must be used in moving the range to avoid personal injury or damage to the unit or the floor The unit is heavy and rests...

Страница 4: ...ian The electrician should also check that the socket cable section is suitable for the electricity drawn by the range z Service should only be done by authorized technicians Technicians must disconne...

Страница 5: ...5 10 x 2 wood screws 4 Anti tip bracket 1 5 16 x 1 1 2 sleeve anchors 2 Lag bolts and washers 2 Foot cover sets 2 PARTS SUPPLIED FOR INSTALLATION...

Страница 6: ...from rear of chassis to front of control panel 27 11 16 703 F Height from top of cook surface to top of pan supports 1 9 16 40 G Height from top of cook surface to top of z vent trim as illustrated z...

Страница 7: ...from rear of chassis to front of control panel 27 11 16 703 F Height from top of cook surface to top of pan supports 1 9 16 40 G Height from top of cook surface to top of z vent trim as illustrated z...

Страница 8: ...from rear of chassis to front of control panel 27 11 16 703 F Height from top of cook surface to top of pan supports 1 9 16 40 G Height from top of cook surface to top of z vent trim as illustrated z...

Страница 9: ...ontrol panel 25 3 8 27 11 16 644 703 25 3 8 27 11 16 644 703 25 3 8 27 11 16 644 703 Non combustible surfaces as defined in National Fuel Gas Code ANSI Z223 1 Current Edition Clearances from non combu...

Страница 10: ...isdiction Combustible RANGE RANGE MOUNT LOW BACKGUARD WALL MOUNT HIGH BACKGUARD LOW SHELF WALL MOUNT HIGH BACKGUARD HIGH SHELF BACKGUARD WIDTH INCHES MM 30 models BGRV2 1230 BGRV2 3030 BGRV3 3030H 29...

Страница 11: ...ods and blowers are designed for use with single wall ducting however some local building codes or inspectors may require double wall ducting and or a damper Consult local building codes and or agenci...

Страница 12: ...the two shipping bolts made visible by removing the lower guard Holding the door on both sides lift door back up to 45 and carefully pull the door out and away from the hinges Before restraining the p...

Страница 13: ...the door out and away from the hinges Open the hinge locks fully on both sides Open the door completely Holding the door at 45 carefully align the hinge tongues with the hinge slots Push the door in u...

Страница 14: ...ator location may vary depending on model SUPPLY AREA DIMENSIONS RIV3 MODELS IN MM A Distance from either edge of range to supply area 1 1 2 38 B Height of electrical supply area from floor 6 152 C De...

Страница 15: ...Electric Code z Observe all governing codes and ordinances when grounding In the absence of these codes or ordinances observe National Electrical Code ANSI NFPA No 70 current issue See the following i...

Страница 16: ...ng for the unit is to be brought into the terminal block through the conduit and through the strain relief The ends of the wiring must have 1 4 faston closed loop lugs attached Make suitable connectio...

Страница 17: ...edition of National Fuel Gas Code ANSI Z 223 1 Warning this appliance must be installed by a licensed plumber or gas fitter when within the Commonwealth of Massachusetts z A manual shut off valve supp...

Страница 18: ...o adjust the height Long hem edge z Ensure the doors and toe kick panel are securely in place if removed previously z Ensure any backguard is fitted prior to final positioning Refer to page 10 for the...

Страница 19: ...ty damage or serious personal injury never use a Iighted match or open flame If a leak is present tighten joint or unscrew apply more joint compound tighten again and retest connection for leak ON GAS...

Страница 20: ...te drill x2 5 16 diameter pilot holes in the center of the larger holes to a depth of at least 1 3 4 3 Place the sleeve anchors into the holes and use a hammer to tap them all the way in 4 Tighten the...

Страница 21: ...as shut off valve installed in an accessible location F Unit tested and free of gas leaks ELECTRICAL F Receptacle with properly rated over current protection is provided for service cord connection F...

Страница 22: ......

Страница 23: ......

Страница 24: ...at any time The product specifications in this document apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specification...

Отзывы: