517793A
9
4.1 Data
Display
To enter the
DATA DISPLAY
screens, push the
LIFECYCLES
button again. This will enable the
out of balance switch to be tested, as well as giving access to the Detailed Fault Codes and User
Warning Faults. One of three displays will appear in the screen. Use the buttons on the bottom of
the display screen to toggle between these displays. Options, up or down.
The
WARNING STATUS
screen will display the
last USER WARNING FAULT that occurred and
will show at what part of the cycle it occurred.
The User Warning Faults are as follows:
•
No Taps
•
Overloaded
•
Out Of Balance
•
Over Suds or water still in the machine
during spin
•
No Hot Water
•
No Cold Water
•
Agitate Overloaded
The
MACHINE STATUS
screen displays the
status of the diverter and the out of balance
switch. It also displays the size setting of the
machine, and the thermistor temperature.
HVDC
is for on line testing in the factory.
Target
temp is the temperature selected.
T
is the actual temp of the inlet chamber water.
The
FAULT STATUS
screen will display a code
for the last fault that has occurred in the
machine. It will also display how many cycles
ago that the fault occurred, and at what part of
the cycle.
See Detailed Fault Codes for servicing tips.
Note: The fault code number can now be checked in the detail fault codes, to ascertain what
repairs may be necessary.