Fisher & Paykel HP60IDCHX3 Скачать руководство пользователя страница 7

5

SAFETY AND WARNINGS

IMPORTANT SAFETY INFORMATION

READ THE ENTIRE SET OF INSTRUCTIONS BEFORE INSTALLING OR USING THIS 

APPLIANCE. A copy of the user guide and installation guide for this product can also 

be found at fisherpaykel.com.

WARNING!

When using this appliance always exercise basic safety precautions including 

the following:

 

z

Read the entire set of instructions before installing or using this appliance.

 

z

Please make this information available to the person installing the 

appliance — doing so could reduce your installation costs. 

 

z

Always switch the power off prior to installation, servicing or cleaning of 

the rangehood.

 

z

This appliance must be installed and connected to the mains power supply only 

by a suitably qualified person according to these installation instructions and 

in compliance with any applicable local building and electricity regulations. 

Failure to install the appliance correctly could invalidate any warranty or 

liability claims.

 

z

To comply with electrical safety regulations, the rangehood must be plugged into 

a socket near the appliance. The socket must be accessible, or have an accessible 

isolating switch, to enable the end user to isolate the rangehood from the power 

for the purpose of internal cleaning or maintenance. 

 

z

A power outlet should be within 750 mm of the motor assembly and can either be 

on the wall, behind the chimney or in the ceiling. 

 

z

If the supply cord of this equipment is damaged, it must only be replaced by the 

manufacturer, its service agent or similarly qualified person in order to avoid a hazard. 

 

z

Ducting accessories are not supplied. All ducting must comply with local requirements 

and building codes.

 

z

Attention should be given to ensure that any applicable regulations concerning 

the discharge of exhaust air are fulfilled. 

 

z

Before connecting any pipes, consult municipal ordinances to ensure that any 

applicable regulations concerning the discharge of exhaust air are adhered to 

and request permission from the person in charge of the building.

 

z

Exhaust air must not be discharged into an existing flue that is used for exhausting 

fumes from appliances burning gas or other fuels. 

 

z

There shall be adequate ventilation of the room when the rangehood is used at 

the same time as appliances burning gas or other fuels. 

 

z

The minimum distance between the supporting surface for cooking vessels on 

the cooktop and the lowest part of the rangehood shall be 600 mm or 650 mm 

if installed over a gas cooktop.

 

z

Stainless steel is very easily damaged during installation if abraded or knocked 

by tools. It is recommended to protect the top of the rangehood with cardboard or 

polystyrene during the installation to minimise the risk of damage occurring. 

 

z

To reduce the risk of damage occurring to the cooktop, it is recommended that 

the surface of the cooktop is protected with cardboard or a similar object during 

installation of the rangehood. 

Содержание HP60IDCHX3

Страница 1: ...BUILT IN INTEGRATED RANGEHOOD HP60IDCHX3 HP90IDCHX3 models INSTALLATION GUIDE USER GUIDE NZ AU ...

Страница 2: ......

Страница 3: ...country go to our website fisherpaykel com or contact your local Fisher Paykel dealer Registration Register your product with us so we can provide you with the best service possible To register your product visit our website fisherpaykel com Introduction 3 Safety and warnings 4 Installation instructions 7 Operating instructions 15 Cleaning and maintenance 17 Parts and accessories 19 Service and wa...

Страница 4: ......

Страница 5: ...eam has spent thousands of hours designing engineering and testing this Integrated Rangehood to ensure you get the perfect product for your home For more information on your product please visit fisherpaykel com or contact our Customer Care team INTRODUCTION ...

Страница 6: ... beam or truss Weight of the product is 8 2 kg HP60 11 5 kg HP90 WARNING Electric Shock Hazard Always disconnect the appliance from the mains power supply before carrying out any maintenance or repairs Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Failure to do so can result in deat...

Страница 7: ...ehind the chimney or in the ceiling z z If the supply cord of this equipment is damaged it must only be replaced by the manufacturer its service agent or similarly qualified person in order to avoid a hazard z z Ducting accessories are not supplied All ducting must comply with local requirements and building codes z z Attention should be given to ensure that any applicable regulations concerning t...

Страница 8: ...ing the method and frequency of cleaning z z There is a fire risk if cleaning is not carried out in accordance with the instructions z z Never leave frying food unattended since grease can overheat and catch fire The risk of fire is even greater in the case of used oil z z Do not flambé under the rangehood z z Never use the rangehood without the filters in place z z During an electrostatic dischar...

Страница 9: ...screw 2 Installation instructions User guide manual 1 125 mm ducting adapter 1 Rangehood 1 BUILT IN INTEGRATED RANGEHOOD HP60IDCHX2 HP90IDCHX2 HP60IDCHX3 HP90IDCHX3 models INSTALLATION GUIDE USER GUIDE NZ AU ROW 150 mm ducting adapter with non return flap 1 ...

Страница 10: ...8 INSTALLATION INSTRUCTIONS J K H I G E B F C A D m A Power cord location Ducting adapter Ø L Product and cabinetry cutout dimensions HP60 HP90 ...

Страница 11: ...sis 220 220 I Length of angled surface of chassis 260 335 J Distance from centre of ducting outlet to back of chassis 145 145 K Distance from centre of ducting outlet to side of chassis 245 395 L Diameter of ducting outlet 150 150 Length of power cord 950 950 CABINETRY CUTOUT DIMENSIONS Overall width of cutout 500 800 Overall depth of cutout 260 260 M Base of brackets clips to bottom of chassis mi...

Страница 12: ...ktop Gas cooktop min 600 max 750 min 650 max 750 Rangehood installation height above the cooktop is the user s preference Lower installation heights will improve the efficiency of capturing cooking odours grease and smoke This rangehood must be installed between the minimum and maximum dimensions indicated in the table above P ...

Страница 13: ...s where flexible ducting is required ensure that it is pulled tight Recirculating This range hood can be installed to recirculate within the kitchen where ducting externally is not practical The carbon filters fit on the blowers within the cavity of the range hood and absorb odours as they pass over the filters The exhaust air then passes through the blower unit and the diverter before recirculati...

Страница 14: ...er with non return flap to the cooker hood using the screws supplied 3 Provide an opening on the underside of the cupboard refer to Product and cabinetry cutout dimensions 4 Remove the filters and face plate of the cooker hood IMPORTANT Venting directly into the cabinet with no ducting and louvered vent is not permitted To recirculate your perimeter insert range hood 1 Determine the desired locati...

Страница 15: ...13 INSTALLATION INSTRUCTIONS 360 1 360 2 360 360 360 360 3 4 5 6 ...

Страница 16: ...he rangehood and fit through the opening of the cupboard till the spring loaded brackets clips hold the product in place x4 6 Secure rangehood while tightening the 4 brackets clips width depth 2 3 2 2 2 1 7 Connect duct and plug rangehood in ...

Страница 17: ...sing the likelihood of condensation on these cooler surfaces Other factors like ambient temperature humidity natural ventilation of the room size of the cookware and how the induction cooktop is being used also influence condensation For example rapid boiling on high cooktop heat settings like PowerBoost increases the rate at which water is evaporated increasing the likelihood of condensation It i...

Страница 18: ...f The lights are dimmable Press and hold to progressively adjust the brightness level Power on off Turn the rangehood on or off The fan automatically turns on to operate at level 1 Fan speed 1 3 Adjust the fan speed levels from 1 3 with 1 being the lowest level and 3 being the highest The fan speed level icon illuminates red when selected Boost Turn the fan onto boost speed The icon flashes red wh...

Страница 19: ...an soft cloth to wipe down all surfaces of the rangehood Do NOT use the following to clean your rangehood they will damage and or discolour the surfaces z z Corrosive chemicals z z Abrasive cleaning products z z Citrus based cleaning products z z Hard brushes and steel wool Note in areas of high humidity or coastal environments cleaning should be carried out more frequently Filter cleaning Alumini...

Страница 20: ...ust be replaced periodically to work properly at least once every three months depending on the frequency with which the rangehood is used Note fully saturated carbon filters can become a barrier to air movement therefore limiting rangehood performance In the event of fire grease laden filters could be flammable and therefore regular replacement is recommended Lighting Slimline LED strip lighting ...

Страница 21: ...SSORIES ITEM REFERENCE NUMBER Aluminium filters FILTER METALLIC GTCL 60 792942 FILTER METALLIC GTCL 90 792943 Recirculation carbon filter x2 792481 Ducting 150 mm kit eaves PD RHK150E Ducting 150 mm kit wall PD RHK150W ...

Страница 22: ... for safe reference Model Serial No Purchase Date Purchaser Dealer Suburb Town Country For details of your manufacturer s warranty and contacts for servicing please refer to your separate service and warranty book provided with your rangehood ...

Страница 23: ......

Страница 24: ...cations in this document apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should therefore check with your Dealer to ensure this document correctly describes the product currently available ...

Отзывы: