background image

6

5

 INSTALLATION INSTRUCTIONS

Recirculation kit — carbon filter (not included)

An optional recirculation kit can be ordered separately and mounted into your range hood, 
see ‘Parts and accessories’ section of your User guide and visit fisherpaykel.com to order.

IMPORTANT!

Venting directly into the cabinet with no vent is not permitted.

WARNING!

This appliance is heavy and requires two persons for unpacking and installation.

Installation work and electrical wiring must be done by qualified person(s) in accordance 

with all applicable codes and standards.

Failure to install the screws or fixing device in accordance with these instructions may 

result in electrical hazards

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other 

hidden utilities.

IMPORTANT!

Wear gloves to protect against sharp edges.

The manufacturer is not liable for any damage caused by not following these instructions.

Before you start installation

Ensure you have read the ‘Installation preparation’ section of this guide.

Unpack the range hood.

Ensure the voltage (V) and the frequency (Hz) indicated on the serial plate match the 
voltage and frequency of the installation site.

Check all functions of the range hood are working.

Check that the area above and behind the installation surface is clear of any electrical cables 
or pipes and there is proper clearance for the ducting etc.

The range hood surfaces can be damaged during installation if grazed or knocked by tools. 
Please take care to protect the surfaces during installation.

Remove protective wrappings that will not be accessible after installation.

Protect the cooktop to prevent damage occurring whilst the range hood is being installed above.

The wall or cabinet used for mounting the range hood should have sufficient strength and 
a flat surface.

WARNING!

Installation work and electrical wiring must be done by qualified person(s) in accordance 

with all applicable codes and standards.

This unit must be earthed/grounded. Improper earthing/grounding can result in a risk of 

electric shock.

1

  Ensure the cabinetry has the required cutout for insertion of the range hood. Refer to the 

‘Cabinetry cutout dimensions’ section of this installation book.

2

  If you are using a duct adaptor this must be installed to the range hood prior to the range 

hood being mounted. Please refer to ‘Duct adaptor assembly’ for details on how to install 
your duct adaptor.

3

  Ensure the mounting brackets are set to the correct position for installation by checking 

the top of the foot lines up with the notches (refer to 

C

). Note: Adjusting the mounting 

bracket up or down from this position prior to installation could cause the range hood to be 
difficult to install and/or damage the cabinetry.

4

  Lift the range hood into the opening until the spring loaded mounting brackets click into 

place and support the weight of the range hood (refer 

D

). For larger size range hoods this 

will require two people. Note: Depending on the cabinetry base panel thickness the range 
hood will be protruding below the cabinetry until tightened. 

5

  Secure the range hood into the cabinetry by tightening each of the mounting brackets in 

counterclockwise

 direction (refer to 

E

). Tighten each bracket in succession around the 

range hood to close the gap incrementally for each bracket.

6

  Remove the junction box cover by removing the two screws (refer to 

F

).

7

  Remove the electrical knockout and install a cULus listed 1/2” (12.7mm) wiring conduit and 

strain relief in the junction box.

8

  Run three wires through the conduit from the power supply to the junction box.

9

  Connect the power supply wires to the range hood wires using suitable cULus listed wire nuts:

–  black to black
–  white to white
–  green/yellow to green/yellow

!0

  Close the junction box cover and secure with screws.

!1

 

Complete the installation

Install the filters as described in the ‘Cleaning and maintenance’ section of your User guide.

Remove all protective wrapping from range hood.

Turn the power on at control panel.

Check the operation of the range hood as described in the ‘Operating instructions’ 
section of your User guide.

Refer to 

G

 for an image of a completed installation.

Содержание HP3019

Страница 1: ...INTEGRATED RANGE HOOD HPB3011 4 HPB3011 6 HPB3019 6 HPB3611 6 HPB3619 6 HPB3619 12 HPB4819 12 HP3019 shell HP3619 shell HP4819 shell models INSTALLATION GUIDE US CA 105305A 06 18 ...

Страница 2: ......

Страница 3: ...nsure they are kept away from children and disposed of properly 2 PRODUCT INFORMATION IMPORTANT SAVE THESE INSTRUCTIONS The models shown in this installation guide may not be available in all markets and are subject to change at any time For current details about model and specification availability in your country please go to our website fisherpaykel com or contact your local Fisher Paykel deale...

Страница 4: ...and HP4819 models HPB3011 4 HPB3011 6 HPB3019 6 HPB3611 6 HPB3619 6 HPB3619 12 and HPB4819 12 models Refer to page 4 for details on Cabinet mounting installation All models T U 1 1 2 38mm C D L M R S G K N J H I O Q B A E c P D c D M S R G J H I B E A c P D F F ...

Страница 5: ... Width of blower housing 13 330 13 330 13 330 13 330 23 1 4 590 23 1 4 590 N A N A N A L Offset of duct adaptor forward of center 0 0 2 11 16 69 0 0 2 11 16 69 0 0 0 0 0 0 0 0 0 0 M Outside diameter of ducting outlet 8 1 4 210 8 1 4 210 8 1 4 210 8 1 4 210 9 13 16 250 9 13 16 250 9 13 16 250 9 13 16 250 9 13 16 250 N Width of duct adaptor 11 3 8 289 11 3 8 289 11 3 8 289 11 3 8 289 12 3 16 310 12 ...

Страница 6: ... of cooking surface to base of the range hood Minimum 30 762 Maximum recommended 42 1067 The installation height ranges from a minimum height of 30 762mm to a maximum recommended height of 42 1067mm Consult the cooktop Installation and User guide for details of the required installation height of the range hood This range hood must be installed no lower than the minimum height indicated in the tab...

Страница 7: ...tems greater than specified cubic feet per minute CFM of air movement The specified CFM varies from locale to locale It is the responsibility of the owner and the installer to determine if additional requirements and or standards apply to specific installations Venting requirements IMPORTANT To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into...

Страница 8: ... grounded Improper earthing grounding can result in a risk of electric shock 1 Ensure the cabinetry has the required cutout for insertion of the range hood Refer to the Cabinetry cutout dimensions section of this installation book 2 If you are using a duct adaptor this must be installed to the range hood prior to the range hood being mounted Please refer to Duct adaptor assembly for details on how...

Страница 9: ...7 5 INSTALLATION INSTRUCTIONS Note The range hood must be installed with the control panel on the right D C E G Power supply conduit F From range hood ...

Страница 10: ...8 6 WIRING DIAGRAM FIELD WIRING COMPARTMENT ...

Страница 11: ......

Страница 12: ...ations in this booklet apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should therefore check with your Dealer to ensure this booklet correctly describes the product currently available ...

Отзывы: