Fisher & Paykel HP24ILTX1 Скачать руководство пользователя страница 22

20

When you purchase any new Fisher & Paykel ventilation hood for personal or consumer 
use you automatically receive a two year limited warranty covering parts and labor for 
servicing within the 48 mainland United States, Hawaii, Washington DC and Canada. In 
Alaska the limited warranty is the same except that you must pay to ship the product 
to the service shop or the service technician’s travel to your home. Products for use 
in Canada must be purchased through the Canadian distribution channel to ensure 
regulatory compliance.

If the product is installed in a motor vehicle, boat or similar mobile facility, you receive 
the same two year limited warranty, but you must bring the vehicle, boat or mobile 
facility containing the product to the service shop at your expense or pay the service 
technician’s travel to the location of the product.

There is no warranty for commercial purchase or use. 

Fisher & Paykel undertakes to:

Repair without cost, with limited exceptions described herein, to the owner either for 
material or labor any part of the product, the serial number of which appears on the 
product, which is found to be defective. In Alaska, you must pay to ship the product 
to the service shop or for the service technician’s travel to your home. If the product 
is installed in a motor vehicle, boat or similar mobile facility, you must bring it to the 
service shop at your expense or pay for the service technician’s travel to the location of 
the product. If we are unable to repair a defective part of the product after a reasonable 
number of attempts, at our option we may replace the part or the product, or we may 
provide you a full refund of the purchase price of the product (not including installation 
or other charges).

This warranty extends to the original purchaser and any succeeding owner of the 
product during the term of the warranty for products purchased for ordinary single-
family home use.

All service under this limited warranty shall be provided by Fisher & Paykel or its 
Authorized Service Agent during normal business hours.

How long does this limited warranty last?

Our liability under this limited warranty expires TWO YEARS from the date of purchase  
of the product by the first consumer.

Our liability under any implied warranties, including the implied warranty of 
merchantability (an unwritten warranty that the product is fit for ordinary use) expires 
TWO YEARS (or such longer period as required by applicable law) from the date of 
purchase of the product by the first consumer. Some States do not allow limitations on 
how long an implied warranty lasts, so this limit on implied warranties may not apply 
to you. Fisher & Paykel will honor any warranty required by the law of the particular 
country or state in which the product is sold.

LIMITED WARRANTY

Содержание HP24ILTX1

Страница 1: ...RIMETER INSERT VENTILATION HOOD HP24ILTX1 and HP36ILTX1 models HOTTE DE VENTILATION PÉRIMÉTRIQUE ENCASTRABLE Modéls HP24ILTX1 et HP36ILTX1 INSTALLATION GUIDE USER GUIDE GUIDE D INSTALLATION GUIDE D UTILISATION US CA ...

Страница 2: ...English Page 1 22 Français Page 25 46 ...

Страница 3: ...n in this user guide may not be available in all markets and are subject to change at any time For current details about model and specification availability in your country please go to our website www fisherpaykel com or contact your local Fisher Paykel dealer Registration Register your product with us so we can provide you with the best service possible To register your product visit our websit...

Страница 4: ......

Страница 5: ...th you This use and care manual will answer most of your questions about the set up use and on going maintenance of your Fisher Paykel product however if you require further information about your product and its use please consult our website for solutions and further contact information to discuss with a service representative To ensure you receive all relevant product updates and the best servi...

Страница 6: ......

Страница 7: ...llow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be ve...

Страница 8: ...MING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a Class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being called You can fight the fire with your back to an exit WARNING Unplug or disconnec...

Страница 9: ...elf tapping screw 4 Power connection box 1 6 152mm diameter Ducting adapter with back draft damper 1 US A INS ALLAT ON NSTRUCT ONS USER GUIDE NST UCT ONS D NS ALL TION GU DE D UT LI AT ON HP 4 L X1 nd H 3 I TX mo e s M èl HP 4 T 1 H 3 I T 1 I t gr t d Pe m t r ns rt en l t on H od Ho e de V n l t o Pé mé r q e E c s r b e EN ...

Страница 10: ...8 INSTALLATION INSTRUCTIONS Product and cabinetry cutout dimensions K L Ø M A E B G D P F C I J H O N UL power connection box Ducting adapter ...

Страница 11: ...ngled surface of chassis 6 7 8 175 11 280 K Distance from center of ducting outlet to back of chassis 3 1 8 80 3 1 8 80 L Distance from center of ducting outlet to side of chassis 9 5 8 245 15 9 16 395 M Diameter of ducting outlet 6 152 6 152 N Distance between center of lights 14 3 4 375 26 9 16 675 O Distance from center of light to front of product 1 9 16 40 1 9 16 40 CABINETRY CUTOUT DIMENSION...

Страница 12: ...ed no lower than the minimum height indicated in the table above Minimum installation height may be greater if required by the cooktop manufacturer or safety and warning section of this user guide Installation at the minimum height will improve the efficiency of capturing cooking odors grease and smoke Installation at the maximum height improves user ergonomics by offering increased head room Q ...

Страница 13: ...ntilation hood can be installed to operate with the exhaust air ducted externally from the kitchen Ducted For ducted installation it is recommended that 6 152mm diameter rigid or semi rigid ducting is used This will require a 6 5 16 160mm min round hole in the ceiling or wall Care should be taken to position the hole correctly For optimal efficiency use the shortest and straightest duct route poss...

Страница 14: ...ch the voltage and frequency at the installation site The stainless steel surfaces of the ventilation hood are very easily damaged during installation if grazed or knocked by tools Please take care to protect the surfaces during installation Protect the cooktop surface below with cardboard or the like to prevent damage occurring whilst the ventilation hood is being installed above 2 Attach ducting...

Страница 15: ......

Страница 16: ......

Страница 17: ...for the ventilation hood black to black and white to white Connect the grounding wire green or bare to the ground conductor green of the ventilation hood power connection box Secure all the connections with cULus listed wire nuts Replace the power connection box cover M Switch Interrupteur Brown Marron Gray Gris Black Noir Red Rouge Blue Bleu Purple Violet White Blanc Yellow Green Jaune Vert White...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ...19 PARTS AND ACCESSORIES ITEM REFERENCE NUMBER Halogen bulb 791961 Aluminum filter 792429 EN ...

Страница 22: ...or vehicle boat or similar mobile facility you must bring it to the service shop at your expense or pay for the service technician s travel to the location of the product If we are unable to repair a defective part of the product after a reasonable number of attempts at our option we may replace the part or the product or we may provide you a full refund of the purchase price of the product not in...

Страница 23: ...authorized repairs E Travel fees and associated charges incurred when the product is installed in a location with limited or restricted access eg airplane flights ferry charges isolated geographic areas f Normal recommended maintenance as set out in the product s user guide g Filter replacement except in the case of faulty parts or materials within the filter cartridge h Damage including water dam...

Страница 24: ...agreement between you and Fisher Paykel regarding any defect in the product and no other express warranty has been made or will be made on behalf of Fisher Paykel None of our employees or our Authorized Service Agents are authorized to make any addition or modification to this limited warranty Warrantor Fisher Paykel Appliances Inc If you need further help concerning this limited warranty or need ...

Страница 25: ......

Страница 26: ......

Страница 27: ...uvent ne pas être disponibles dans tous les pays et sont sujets à modifications sans préavis Pour les plus récentes informations sur la disponibilité des modèles et des caractéristiques dans votre pays veuillez visiter notre site Web www fisherpaykel com ou contacter votre détaillant Fisher Paykel local Enregistrement Enregistrez votre produit afin que nous puissions vous offrir un service de la m...

Страница 28: ......

Страница 29: ... d entretien répond à la plupart des questions concernant l installation l utilisation et l entretien de routine de votre produit Fisher Paykel toutefois si vous avez besoin d informations supplémentaires au sujet de votre produit et de son fonctionnement veuillez visiter notre site Web pour obtenir des solutions et des coordonnées permettant de communiquer avec un représentant de service Pour vou...

Страница 30: ......

Страница 31: ...son ainsi que les normes de sécurité comme celles publiées par la National Fire Protection Association NFPA et la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE ainsi que les normes locales Au moment de couper ou percer le mur ou le plafond veillez à ne pas endommager le câblage électrique ou les conduites qui y sont dissimulés Les ventilateurs avec conduits doive...

Страница 32: ... pourriez vous brûler N UTILISEZ PAS DE L EAU ni de linges ou serviettes humides car cela pourrait causer une violente explosion de vapeur Utilisez un extincteur UNIQUEMENT si Vous savez qu il s agit d un extincteur de classe ABC et vous savez vous en servir Le feu est peu important et localisé dans la zone où il a commencé Vous avez appelé le service d incendie Vous pouvez combattre le feu en aya...

Страница 33: ...lapet anti refoulement d air 1 Hotte de ventilation 1 Boîtier de raccordement d alimentation 1 Vis autotaraudeuses de 3 8 po 10mm 4 US CA NSTALLA ION INST UCTIONS USER GUIDE IN TRUCT ONS D IN TAL AT ON G IDE D UT L SAT ON H 24 TX and P3 LT 1 m de s M èl H 2 I T 1 t P3 L X1 n eg a ed P r me er n e t Ve t a i n ood H t e de e t a i n P r mé i ue nc s ab e FR ...

Страница 34: ...32 INSTRUCTIONS D INSTALLATION Dimensions du produit et de l ouverture dans l armoire K L Ø M A E B G D P F C I J H O N Boîtier de raccordement d alimentation UL Adaptateur de conduit ...

Страница 35: ...8 po 175 11 po 280 K Distance entre le centre de la sortie de conduit et l arrière du châssis 3 1 8 po 80 3 1 8 po 80 L Distance entre le centre de la sortie de conduit et le côté du châssis 9 5 8 po 245 15 9 16 po 395 M Diamètre de la sortie de conduit 6 po 152 6 po 152 N Distance entre le centre des lampes 14 3 4 po 375 26 9 16 po 675 O Distance entre le centre de la lampe et l avant du produit ...

Страница 36: ... dans le tableau ci dessus La hauteur d installation minimale peut être augmentée si nécessaire suivant les instructions du fabricant de votre surface de cuisson ou les consignes de sécurité et mises en garde décrites dans ce manuel Une installation à la hauteur inférieure améliore l efficacité de l appareil pour l élimination des odeurs de la graisse et de la fumée de cuisson Une installation à l...

Страница 37: ...installée de manière à fonctionner en évacuant l air à l extérieur de la cuisine par un conduit Avec conduit Pour l installation avec conduit il est recommandé d utiliser un conduit rigide ou semi rigide de 6 po 152mm de diamètre Un trou circulaire de 65 16 po 160mm min est alors requis dans le plafond ou le mur Veuillez vous assurer de positionner le trou correctement Pour une efficacité optimale...

Страница 38: ...e site d installation Les surfaces en acier inoxydable de la hotte de ventilation peuvent être très facilement endommagées pendant l installation en cas de frottement ou contact avec un outil Veuillez vous assurer de protéger les surfaces pendant l installation Protégez la surface de cuisson située sous l appareil avec du carton ou un matériau semblable pour éviter de l endommager pendant l instal...

Страница 39: ......

Страница 40: ......

Страница 41: ...a hotte de ventilation le noir au noir et le blanc au blanc Connectez le fil de mise à la terre vert ou dénudé au conducteur de mise à la terre vert du boîtier de raccordement d alimentation de la hotte de ventilation Fixez tous les raccordements à l aide de capuchons de connexion homologués cULus Réinstallez le couvercle du boîtier de raccordement d alimentation M Switch Interrupteur Brown Brun G...

Страница 42: ......

Страница 43: ......

Страница 44: ......

Страница 45: ...43 PIÈCES ET ACCESSOIRES ARTICLE NUMÉRO DE RÉFÉRENCE Ampoule halogène 791961 Filtre en aluminium 792429 FR ...

Страница 46: ...ration ou le déplacement d un technicien à leur domicile Si le produit est installé dans un véhicule à moteur un bateau ou une installation mobile similaire vous devez l apporter à l atelier de réparation à vos frais ou payer le déplacement d un technicien à l endroit où se trouve le produit Si nous ne parvenons pas à réparer une pièce défectueuse du produit après un nombre de tentatives raisonnab...

Страница 47: ... la correction de telles réparations non autorisées E Les frais de déplacement et frais associés encourus lorsque le produit est installé dans un endroit où l accès est limité ou restreint par exemple frais d avion et de traversier régions géographiques isolées f L entretien normal recommandé dans le guide d utilisation du produit g Le remplacement du filtre sauf en présence de pièces ou matériaux...

Страница 48: ...itue la totalité de l accord exclusif existant entre l acheteur et Fisher Paykel relativement à toute défectuosité de ce produit aucune autre garantie expresse n est offerte ou ne sera offerte au nom de Fisher Paykel Aucun de nos employés ou agents de service autorisés n est autorisé à effectuer des ajouts ou apporter des modifications à cette garantie limitée Garant Fisher Paykel Appliances Inc S...

Страница 49: ......

Страница 50: ......

Страница 51: ......

Страница 52: ...Dealer to ensure this booklet correctly describes the product currently available Fisher Paykel Appliances 2017 Tous droits réservés Les caractéristiques de produit présentées dans ce livret s appliquent aux modèles et produits spécifiques qui y sont décrits à la date de publication Dans le cadre de notre politique d amélioration en permanence de nos produits ces caractéristiques peuvent être modi...

Отзывы: