Height of wall canopy

 

The wall canopy is designed for 2440 mm high ceilings.

 

The chimney is telescopic and is designed for wall canopy 
installations between 650 to 750 mm above the cooking surface.

 

Ascertain the desired installation height of the wall canopy.

 

Any installation above 750 mm will compromise the  
extraction performance.

 

The air outlet from the motor requires 150 mm round ducting  
which requires a 160 mm (min) diameter hole in the ceiling.

A

 = 600 min (electric cook top)

A

 = 650 min (gas cook top)

B

 = 225 mm

C

 = 260 mm

Ducting options

Recirculation

For recirculation, please purchase a recirculation kit (part no. RR1744). The recirculation kit is 
required to channel the air out through the side-vents at the top of the flue. 

Note: a ducting hole is not required in the wall or ceiling if a recirculation kit is fitted. 

Ducting

For ducted installation, it is recommended that you use 150 mm diameter, rigid or semi-rigid 
ducting. This will require a 160 mm (min) round hole in the ceiling, which the decorative chimney 
will cover. Care should be taken to align the canopy with the decorative chimney allowing 
sufficient clearance to accommodate the ducting.

For optimal efficiency, use smooth-wall, solid galvanized or plastic ducting for reduced noise and 
increased airflow.  Flexible ducting should only be used as a last resort (ie in difficult installations) 
and if used, ensure that it is pulled tight. 

The smoother, straighter and shorter the ducting the quieter and more efficient the wall canopy 
will perform.

All ducting must comply with local requirements and building codes.

Note: we recommend an Easy Fit by Fisher & Paykel or a UNIDUCT ducting system, products that 
have been designed to expel air efficiently.

Preparing the wall canopy for installation

 

Please read the instructions carefully before installing the wall canopy.

 

Remove the filters from the canopy to allow access to wall mounting holes. To remove the filters, 
pull the relative catch, tilting it downwards until it disengages from the supports. Reverse these 
instructions when refitting the filters.

 

Prior to drilling any holes, check that the area behind the surface to be drilled is clear of any 
electrical cables or pipes etc. 

 

Stainless steel/Iridium is very easily damaged during installation if abraded or knocked by tools.

 

Whenever possible, protect the cooktop with cardboard or the like, to prevent damage  
on installation.

Fig.2 Positioning

Filter surface

Cooktop

Содержание HC90DMB1

Страница 1: ...Designer series wall canopy NZ AU GB IE HC90DXB1 HC90DMB1 models Installation instructions and User guide ...

Страница 2: ...r care 8 Contents Important SAVETHESEINSTRUCTIONS The models shown in this User Guide may not be available in all markets and are subject to change at any time For current details about model and specification availability in your country please visit our local website listed on the back cover or contact your local Fisher Paykel dealer ...

Страница 3: ...wer off prior to installation servicing or cleaning the wall canopy Never use the wall canopy without the filters in place Stainless steel is very easily damaged during installation if abraded or knocked by tools It is recommended to protect the top of the canopy with cardboard or polystyrene during the installation to minimise the risk of damage occurring A power outlet should be within 750 mm of...

Страница 4: ... 12 x 2 screw 2 x cup washer 3 x 8 x 1 25 screw 1 x wall anchor 4 x 6 x self tapping screw Typical equipment required Electric drill Screwdriver Duct tape Jig saw Ladder Ducting Tape measure Drill bits Spirit level Accessories Accessory Part Number Chimney ext 3048 mm 10 ceiling SS RR1740 Chimney ext 3657 6 mm 12 ceiling SS RR1740 Chimney ext 3048 mm 10 IR 89092 Chimney ext 3657 6 mm 12 IR 89093 R...

Страница 5: ...wing sufficient clearance to accommodate the ducting For optimal efficiency use smooth wall solid galvanized or plastic ducting for reduced noise and increased airflow Flexible ducting should only be used as a last resort ie in difficult installations and if used ensure that it is pulled tight The smoother straighter and shorter the ducting the quieter and more efficient the wall canopy will perfo...

Страница 6: ... wall canopy with a centre line 100 mm from the wall for the ceiling option 6 Using the screws supplied fix the chimney bracket to the wall or ceiling checking that it is centrally located above the canopy 7 Remove the protective plastic covering from all parts including the filters 8 Fit the wall canopy onto the mounting screws and tighten 9 Connect and secure the ducting use duct tape if require...

Страница 7: ...OFF SWITCH Enables the wall canopy to remain on a low mid or high speed for five minutes to clear away all residual cooking odours before switching off automatically Fig 5 Control panel Fan On Off Mid Speed High Speed Delay Off Switch Light On Off ...

Страница 8: ...oking vapours prior to the cleansed air re entering the kitchen when the wall canopy is in recirculating mode Charcoal filters are disposable items and it is recommended that these should be replaced every three to six months depending on use Note Fully saturated charcoal filters can become a barrier to air movement impeding the wall canopy s performance In the event of fire fully grease laden fil...

Страница 9: ...ther than 1 Normal domestic use or 2 Use in accordance with the Product s User Guide C Defects to the Product caused by accident neglect misuse or Act of God D The cost of repairs carried out by non authorised repairers or the cost of correcting such unauthorised repairs E Normal recommended maintenance as set out in the Product s User Guide F Repairs when the appliance has been dismantled repaire...

Страница 10: ...iance Your dealer or our Customer Care Centre can recommend an Authorised Service Centre in your area In Australia if you need assistance Call the Fisher Paykel Customer Care Centre and talk to one of our Customer Care Consultants Toll Free 13 00 650 590 Fax 07 3826 9298 Email customer care fp com au Postal Address PO Box 798 Cleveland QLD 4163 If you need service Fisher Paykel Australia Pty Ltd h...

Страница 11: ... number serial number date of purchase and a description of the problem This information is needed in order to better respond to your request for assistance Product Details Fisher Paykel Appliances Ltd Model Serial No Date of Purchase Purchaser Dealer Suburb Town Country ...

Страница 12: ...ontinuous product improvement these specifications may change at any time You should therefore check with your Dealer to ensure this booklet correctly describes the product currently available www fisherpaykel co nz www fp com au www fisherpaykel co uk www fisherpaykel ie NZ AU GB IE Designer series wall canopy Installation instructions and user guide Published 02 2009 Part No 400005 D ...

Отзывы: