Fault 3:
3 beeps
Reason:
The resistance of FC sensor is outside the normal range (> 45K Ohms)
Primary Action:
Check the 4-way connector at the control module.
Secondary Action: Check sensor resistance.
Reterminate the 4-way connector.
Tertiary Action:
Replace control module.
Fault 4:
4 beeps
Reason:
The resistance of FC sensor is outside the normal range (< 660 Ohms)
Primary Action:
Check the 4-way connector at the control module.
Secondary Action: Check sensor resistance.
Reterminate the 4-way connector.
Tertiary Action:
Replace control module.
Fault 7:
7 beeps
Reason:
The resistance of defrost sensor is outside the normal range (> 45K Ohms)
Primary Action:
Check the 4-way connector at the control module.
Secondary Action: Check sensor resistance.
Reterminate the 4-way connector.
Tertiary Action:
Replace control module.
Fault 8:
8 beeps
Reason:
The resistance of defrost sensor is outside the normal range (< 660 Ohms)
Primary Action:
Check the 4-way connector at the control module.
Secondary Action: Check sensor resistance.
Reterminate the 4-way connector.
Tertiary Action:
Replace control module.
Fault 9:
9 beeps
Reason:
Compressor has failed to start after 5 attempts
Primary Action:
Check the integrity of the compressor
Secondary Action: Replace control module.
Fault 10:
10 beeps
Reason:
The control variable resistor has an open circuit fault.
Primary Action:
Check the continuity of the circuit between the variable resistor and the control
module and the connections at the variable resistor and the control module.
Secondary Action: Replace control module