Fisher & Paykel DOUBLE DISHDRAWER DD24DDFT Скачать руководство пользователя страница 8

7

6

 

CAVITY PREPARATION

Water Connection

Recommended 

HOT

(Maximum 140°F/60°C).

Supplied hose to
suit 3⁄8” (9 mm) male
compression fitting.

Kosher requirements

Drains will need to be 
separated to satisfy 
kosher requirements. 
We suggest you confirm 
acceptability with your 
local rabbi in respect to 
kosher installations.

Water Pressure
 

Water softener models

Max. 1 MPa (145 psi)
Min.  0.1 MPa (14.5 psi)
 

Models without water softener

Max. 1 MPa (145 psi)
Min.  0.03 MPa (4.3 psi)

IMPORTANT!

The power outlet 
must be located in a 
cabinet adjacent to the 
dishwasher cavity. 
110-120 VAC max. 15 A

ø max. 1 1/2” 
(38 mm)

max. 17 11⁄16”
(450 mm)

min. 7 7⁄8” (200 mm)

Moisture 
protection 
tape must 
be applied.

Services hole

Can be located either side of dishwasher, preferably 
at the bottom of the cavity, as shown. If adequate 
clearance, services hole can be made higher to clear 
toekick space. If hole is higher, ensure drain hose(s) 
are routed straight into the waste connection.

 

If the hole is through wood, make sure its edges are 
smooth and rounded.

 

If the hole is through metal, ensure you fit the supplied 
Edge Protector to prevent damage to the power cord.

These marks indicate 
formed bracket screw 
locations, if securing by 
drawer removal.

If there is no side
partition, you can 
construct timber 
bracing as something 
to secure into.

3/8” 
(10 mm)

COUNTERTOP

Содержание DOUBLE DISHDRAWER DD24DDFT

Страница 1: ...591385 A 08 17 INSTALLATION GUIDE US CA DOUBLE DISHDRAWERTM DISHWASHER DD24DDFT DD24DV2T models...

Страница 2: ...ilar mobile facility you must bring the vehicle boat or mobile facility containing the product to the service shop at your expense or pay the service technician s travel to the location of the product...

Страница 3: ...er Wire clip 2 for securing Drain hose joiner Phillips 5 8 16 mm screws 9 Drain hose support 1 Moisture protection tape 1 to prevent moisture damage to cabinetry Drain hose joiner 1 Top mounting brack...

Страница 4: ...ide the terminal block cover sideways to unlock and hinge open to access the terminal block 6 Unscrew the Live Neutral and Earth wires as shown 7 Unscrew the three screws on the base as shown and remo...

Страница 5: ...d through or under under housing ribs 9 Screw down the Live Neutral and Earth wires correctly 10 Push the plastic harness cover back over It should clip back into place 11 Fold down and slide back the...

Страница 6: ...r front panels 30 762 30 762 H Height of upper drawer front panel 17 3 8 442 17 3 8 442 I Height of lower drawer front panel 12 1 4 312 12 1 4 312 J Height from top of drawer front panel to top of cha...

Страница 7: ...in 34 864 min 34 864 Q Inside width of cavity 23 5 8 600 24 610 R Inside depth of cavity min 22 1 16 560 min 22 1 16 560 S Recommended height of adjacent cabinet space 30 762 30 762 T Height of toekic...

Страница 8: ...120 VAC max 15 A max 1 1 2 38 mm max 17 11 16 450 mm min 7 7 8 200 mm Moisture protection tape must be applied Services hole Can be located either side of dishwasher preferably at the bottom of the ca...

Страница 9: ...OSES CORD FROM CHASSIS EDGE LEFT HAND SIDE RIGHT HAND SIDE Drain hoses 78 1 2 2000mm Drain hoses 70 1 2 1800mm Inlet hose 64 3 4 1650mm Inlet hose 49 1250mm Power cord excl plug 29 1 2 750mm Power cor...

Страница 10: ...flat bladed screwdriver Ensure they re securely fitted before sliding product into cavity The mounting slots are in pairs one on each side diagonally across the product A bracket must match A slot and...

Страница 11: ...ewdriver prise the grey rubber plug out of the trim moulding Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward Repeat for all four brackets Using a sm...

Страница 12: ...8 B PULL THROUGH HOSES PUSH INTO THE CAVITY 9 B REMOVE THE LOWER DRAWER To prevent kinked hoses Either sit the drawer down on the left hand side recommended or rotate the drawer clockwise resting it o...

Страница 13: ...Ensure product is level and aligning with cabinetry Hexagonal socket The top mounting brackets will only bend upwards a maximum of 10 mm 2 B REFIT THE DRAWER ONTO THE RUNNERS Before refitting the dra...

Страница 14: ...pencil Lay the toekick face down on a chopping board or similiar Smooth the edges with a file Be careful of sharp edges Snap off the two end tabs Slide the toekick onto the mounting rails either side...

Страница 15: ...IMPORTANT Ensure that drain connection will comply with local plumbing regulations min R 8 200 mm 29 1 2 34 3 4 750 882 5 mm 1 1 2 38 mm 29 1 2 34 3 4 750 883 mm Screw Drain hose support to back wall...

Страница 16: ...al Double Air Gap Break Kit This provides totally separate draining for each drawer and eliminates possible cross draining problems DRAINAGE OPTION 2 Dishwasher using Dual Air Gap Break with Drain Hos...

Страница 17: ...883 mm step 15 Supplied drain hose joiner to suit 3 4 19 mm waste tee Ensure drain hose is routed straight to joiner Remove excess drain hose material if necessary Do not shorten the inlet hose 29 1...

Страница 18: ...ed on If it is and still no indicator ligths up see the Preference options section of the Quick start guide An option called Open drawer auto power on may need to be turned on Water around water suppl...

Страница 19: ...igher than the drain hose joiner Ensure any packaging or tape securing the racks is removed from the drawers Water softener models only adjust the water softener setting from the default setting to su...

Отзывы: