PLUMBING & ELECTRICAL CONSIDERATIONS

SERVICE DIMENSION

LEFT SIDE*

RIGHT SIDE*

MM

MM

Length of drain hoses

2000

1800

Length of power cord**

2000

2000

Length of inlet hose

1650

1250

Distance from floor to top of hose support

750  - 883

750  - 883

Minimum distance from floor to end of drain hoses***

500

500

Minimum distance from floor to inlet hose connection

200

200

Maximum distance from cabinetry centre of electrical outlet

450

450

*dimensions taken from the chassis edge where applicable
**excluding plug
***standpipe install illustrated. Distance is the same for all plumbing installs.

Hose and cord lengths

 

z

Your services can be installed to either the left-hand or right-hand side 
of the product in an adjacent cabinet. Refer to ‘Cabinetry preparation’ 
for service access requirements.

 

z

If the drain hoses supplied are not long enough to reach your services, 
you may purchase a Fisher & Paykel drain hose extension kit which will 
extend the drain hoses by 3.6m (part number 525798).

Water connection

 

z

Recommended water temperature: Cold (maximum 60°C)

 

z

3/4” BSP (GB20) to suit flat washer

 

z

Ensure water connection complies with local plumbing regulations.

Water pressure

 

z

Water softener models: max. 1 MPa (145 psi), min. 0.1 MPa (14.5 psi)

 

z

Non-water softener models: max. 1 MPa (145 psi), min. 0.03 MPa (4.3 psi)

Electrical requirements

 

z

220-240VAC min 4.8A

Assisted Opening electrical requirements

 

z

A double power socket is required

a

a

b c

b

c

d

d

e

e

f

f

Содержание DISHDRAWER DD60STX6HI1

Страница 1: ...INSTALLATION GUIDE INTEGRATED DD60STX6I1 DD60STX6HI1 SINGLE DISHDRAWER DISHWASHER NZ AU BI...

Страница 2: ......

Страница 3: ...be plugged into an appropriate outlet that is installed and earthed in accordance with all local codes and ordinances Do not modify the power supply plug provided with the appliance if it will not fit...

Страница 4: ...Regulations z The DishDrawer Dishwasher MUST be installed to allow for future removal from the enclosure if service is required z The switched power outlet must be outside the dishwasher cavity so tha...

Страница 5: ...asher 1 Drain hose support 1 Flat blade screwdriver Level Top mounting bracket kit 1 38mm bottom fixing screws and washers 2 Drain hose joiner 1 Powered driver Pliers Box cutter Router Pencil Multi to...

Страница 6: ...height 454 B Overall width 599 C Overall depth 571 D Depth of chassis 553 E Front panel depth 16 20 F Max drawer extension 527 based on front panel thickness of 18mm refer to Custom panel dimension f...

Страница 7: ...an 18mm high spacer and two 55mm high spacer blocks including 18mm door panels on adjacent cabinetry when venting through the same or adjacent cabinet Refer to External venting preparation for more in...

Страница 8: ...8 CABINETRY CLEARANCES MM A Minimum clearance to adjacent cabinetry 2 B Minimum clearance to corner cabinetry 13 B A PLAN CLEARANCES...

Страница 9: ...n panel placement refer to fisherpaykel com ISO PROFILE Material specifications z Maximum weight of panel must not exceed 9kg including handle z The panel should be adequately sealed to withstand mois...

Страница 10: ...ices can be installed to either the left hand or right hand side of the product in an adjacent cabinet Refer to Cabinetry preparation for service access requirements z If the drain hoses supplied are...

Страница 11: ...service hole 10 C Minimum diameter of service hole 57 D If venting through the adjacent cabinetry the rear edge of the service hole should be enlarged by cutting out the bottom corner A B C D z Servi...

Страница 12: ...ice hole must be also be created through the shelf and the base of the cavity to route the venting hose through z Frameless cabinetry A 100mm x 200mm cutout must be created at the front of the cabinet...

Страница 13: ...e product to either the left or right depending on your venting location Push the vent hose onto the elbow firmly to secure We recommend fitting the trim bracket when installing your DishDrawer Dishwa...

Страница 14: ...o secure Push the duct onto the cabinetry and secure using the four provided screws Framed cabinetry Route the venting hose to the cutout and push onto the duct firmly to secure Place duct into cutout...

Страница 15: ...s oriented correctly and is not in contact with the bracket before securing On the back of the panel mark the centre and align the base of the bracket with the base of the panel Re insert both side pi...

Страница 16: ...sulation is replaced correctly 3 1 2 4 Open the drawer and press both locking tabs back to release Lift the drawer off the runners and set aside on a protected surface Push runners back in Take care n...

Страница 17: ...se is routed straight to the joiner removing excess drain hose if necessary Do not shorted the inlet hose Unplug or drill out the waste tee before securing joiner to sink trap or waste tee Plug produc...

Страница 18: ...highloop Ensure inlet hose has supplied rubber washer fitted and that it s tightened If connecting the drain hose to the sink trap ensure the highloop is a minimum 150mm higher than the drain hose jo...

Страница 19: ...ed z Ensure power is connected and is switched on z AUTO POWER ON may need to be activated Refer to your User guide for details Drawer doesn t close properly z Ensure nothing is obstructing the drawer...

Страница 20: ...e product specifications in this guide apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at an...

Отзывы: