6

max. 450mm

Service Holes

Can be located either side of dishwasher, close to the rear face 
and the shelf, as illustrated.

O

If the hole is through wood, make sure its edges are smooth 
and rounded.

O

If the hole is through metal, ensure you fit the supplied Edge 
Protector to prevent damage to the power cord.

These marks indicate formed 
bracket screw locations, if 
securing by drawer removal.

If there is no side partition, you 
can construct timber bracing 
as something to secure into.

Moisture 
protection tape 
must be applied

10 mm

COUNTERTOP

WARNING!

Incorrect placement of the hole 
will result in damage to hoses.

Ø 57mm

Max 10mm

Max distance between 
hole edge and shelf

Max 5mm

Max distance 
between hole edge 
and rear inner face

5

 

CAVITY PREPARATION

Water Connection

Recommended 

COLD

 

(Maximum 60°C).

3/4“ BSP (GB20) to 
suit flat washer.

Water Pressure
 

Water softener models

Max. 1 MPa (145 psi)
Min. 0.1 MPa (14.5 psi)
 

Models without water softener

Max. 1 MPa (145 psi)
Min. 0.03 MPa (4.3 psi)

IMPORTANT!

The power outlet must be 
located in a cabinet adjacent 
to the dishwasher cavity. 
220-240 VAC min. 4.8 A

min. 200 mm

Содержание DishDrawer DD60SA

Страница 1: ...DD60SA DD60SC models SINGLE DISHDRAWER DISHWASHER 591151D 05 19 INSTALLATION GUIDE NZ AU GB IE SG...

Страница 2: ...t earthing conductor and an earthing plug The plug must be plugged into an appropriate outlet that is installed and earthed in accordance with all local codes and ordinances Failure to follow this adv...

Страница 3: ...al from the enclosure if service is required O The switched power outlet must be outside the dishwasher cavity so that it is accessible after installation O Care should be taken when the appliance is...

Страница 4: ...e joiner Phillips 16 mm screws 7 38 mm bottom fixing screws metal washers 2 Drain hose support 1 Moisture protection tape 1 to prevent moisture damage to cabinetry Drain hose joiner 1 Top mounting bra...

Страница 5: ...9 C Overall depth of product 573 573 D Depth of chassis to back of front drawer panel 553 553 E Depth of drawer front panel 20 20 F Height of drawer front panel 393 437 G Height of chassis1 410 454 H...

Страница 6: ...SA DD60SC DD60SCT CABINETRY DIMENSIONS MM MM K Inside height of cavity min 412 min 456 L Inside width of cavity 600 600 M Inside depth of cavity min 560 min 560 min 412mm min 456mm K K Dishwasher Dish...

Страница 7: ...ing as something to secure into Moisture protection tape must be applied 10 mm COUNTERTOP WARNING Incorrect placement of the hole will result in damage to hoses 57mm Max 10mm Max distance between hole...

Страница 8: ...UM DISTANCE OF HOSES CORD FROM CHASSIS EDGE LEFT HAND SIDE Drain hose 2000 mm Drain hoses 1800 mm Inlet hose 1650 mm Inlet hose 1250 mm Power cord excl plug 2000 mm Power cord excl plug 2000 mm RIGHT...

Страница 9: ...o not use excessive force as doing so may squash the hoses and lead to incorrect operation A A A B B Clip all four side mounting brackets into their slots using a flat bladed screwdriver Ensure they r...

Страница 10: ...rubber plug out of the trim moulding Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward Repeat for all four brackets Using a small Philips screwdriver...

Страница 11: ...n either side and push back to release drawer from runners Lift drawer off runners Push drawer runners back in on either side Push drawer runners back in on either side Sit the drawer down Rotate the...

Страница 12: ...ti clockwise the drawer back onto the drawer runners on either side Pull the release tabs forward on both sides 100 mm Ensure the tabs are fully pulled forward and click into place Release tab The pro...

Страница 13: ...crew Drain hose support to back wall at correct height If space is limited for fixing push hose through drain hose support to required height IMPORTANT Ensure that drain hose is installed as close to...

Страница 14: ...13 Ensure the supplied rubber washer is fitted inside the coupling Tighten coupling with spanner 180o No leaks 1 2 min 10mm 3 4 BSP connector 3 CONNECT INLET HOSE TO COLD WATER 4 PLUG PRODUCT IN...

Страница 15: ...If it is and still no indicator ligths up see the Preference options section of the Quick start guide An option called Open drawer auto power on may need to be turned on O Water around water supply an...

Страница 16: ...mum 150 mm higher than the drain hose joiner Ensure any packaging or tape securing the racks or spray arms is removed from the drawers Water softener models only adjust the water softener setting from...

Отзывы: