BEFORE YOU START
PARTS SUPPLIED
INTEGRATED PARTS KIT
part no. 526674
Panel
Preparation
Booklet (1)
TOOLS NEEDED
Safety Glasses, Tape Measure, Pencil, Needle-Nose Pliers, Drill & Phillips
Bit or Phillips Screwdriver,
ø
1” (25.4mm) Boring Bit or
ø
1” (25.4mm)
Hole Saw, Small Hand or Jig Saw.
IMPORTANT
INTEGRATED PANEL THICKNESS
Upper and Lower Panel minimum thickness is
5
/
8
” (16mm). Panel
thicknesses above
11
/
16
” (18mm) can be accommodated but product depth
will increase accordingly.
INTEGRATED PANEL MATERIAL
Drawer Front material must be suitable for damp conditions
(122
o
F/50
o
C @ 80% RH)
and adequately sealed to withstand moisture.
Additional protection can be provided by using a “Moisture Resistant
Board”. Taping edges alone may not provide adequate sealing. For
painted panels, radius all rear edges to improve sealing.
2
R
TOE KICK PREPARATION
TOE KICK OPTIONS
A)
The Black Prefinished Toe Kick Panel is supplied. Refer to Installation
Instructions
for
preparation.
B)
The Black Prefinished Toe Kick Panel can also have a front panel of
your choice attached to it using screws or an adhesive.
C)
A Toe Kick panel of any material with thickness from
3
/
8
” -
3
/
4
”
(9-19mm) can be screwed to a plastic Toe Kick Mounting Bracket
(supplied).
TOE KICK PANEL INSTALLATION DEPTH
When using a rectangular Toe Kick, the maximum depth, excluding the
Toe Kick Panel is 2
5
/
8
” (67mm).
To move the Toe Kick deeper the Toe Kick Panel must have the profile
shown in the diagram below cut out of it. The maximum Toe Kick depth
with the cut out excluding the Toe Kick Panel is 5” (127mm).
WIDTH OF TOE KICK PANEL
Refer to “Width of All Panels” on page 1.
[Height of adjacent
cabinetry]
HEIGHT OF TOE KICK PANEL
Refer to the diagram on page 1. Measure
the height from the top of the
adjacent cabinet door fronts to the floor and write it in the first box below,
then complete the equation.
For example:
[
R
dimension]
[MIN
clearance]
[height of Toe
Kick Panel,
MIN 2
3
/
4
”
(70.5mm)]
IMPORTANT
WARNING!
BE SURE THE PRODUCT IS NOT PLUGGED IN.
Important!
The installation of the Panels requires an electrical
connection and must be performed by a suitably
qualified person.
Panel
Mounting
Screws (12)
Toe Kick
Mounting
Screws (5)
Door Front Seal (2)
p.n 526466
Mounting Bracket (2)
(Upper and Lower)
p.n 526440 & 526441
Integrated Rectangular Badge (2)
(Satin Chrome supplied)
p.n 526975
Other Badges Available
Rectangular:
Bright Chrome Kit p.n 527276
Brass Kit p.n 527277
Eliptical:
Black Kit p.n 526683
Satin Chrome Kit p.n 526684
Bright Chrome Kit p.n 527156
Brass Kit p.n 526685
Toe Kick Mounting Bracket (1)
p.n 526682
34
1
/
4
”
(870mm)
0”
28
15
/
16
”
(735mm)
15
/
32
”
(12mm)
4
27
/
32
”
(123mm)
28
15
/
16
”
(735mm)
15
/
32
”
(12mm)
[Door extension]