Fisher & Paykel DD90S(H)TI2 (Integrated) Скачать руководство пользователя страница 24

24

26

25

FINAL CHECKLIST

TROUBLESHOOTING

Check all parts are installed.

Ensure product is level, securely fastened to the cabinetry and opens and 

closes freely. The drawer must be free to fully close with no resistance from the 

cabinetry.

Ensure inlet hose to water supply has supplied rubber washer fitted, and that 

it’s tightened a further half turn after seal contact.

Ensure any knockouts or plugs in drain connection have been drilled out and 

drain connection has been made.

The drain hose joiner must not support the weight of excess hose material. 

Keep drain hose as fully extended as possible to prevent sagging. Any excess 

length of drain hose should be kept on the dishwasher side of the highloop.

If connecting the drain hose to the sink trap, ensure the Highloop is a minimum 

150 mm higher than the drain hose joiner.

Ensure any packaging or tape securing the racks is removed from the drawer.

Turn on the power and water supplies, then open the drawer. You should hear a 

beep and see a program indicator light up on the internal control panel.

Check the spray arms are in place and free to rotate.

Add three cups of water into the drawer. Press 

 on the internal control panel 

until the indicator of the ‘Rinse’ program lights up. Close the drawer and press 

 to start the program.

After the Rinse program has finished, ensure the dishwasher has run and 

drained correctly.

Check water supply and drainage connection for leakage.

 

Excessive water remaining above the filter plate, after the rinse cycle

 

Check for a kinked drain hose or blocked waste connection, highloop not 
properly installed or drain hose not routed correctly.

 

No water supply (This is displayed as a ‘U1’ fault -- see section ‘If there is a 
fault’ in the User guide for how to recognise this fault on models without a 
display.)

 

Check water is connected and turned on.

 

The dishwasher is beeping continuously

 

There is a fault. See section ‘If there is a fault’ in the User guide for further 
information and instructions.

 

No program indicator lights up when the drawer is opened

 

Ensure power is connected and is switched on. If it is and still no indicator 
ligths up, see the ‘Preference options’ section of the ‘Quick start guide’. An 
option called ‘Open drawer auto power-on’ may need to be turned on.

 

Water around water supply and drainage connections 

 

Check connections, existing plumbing and hoses for leaks. Check rubber 
washer and hose clamp are correctly fitted.

 

If product is tipping

 

Ensure the product is secured to the cabinetry. 

 

If front panels are misaligned

 

Check and relevel product. Check the cabinetry is square. Check and adjust 
front panel alignment if necessary.

 

Drawer doesn’t close properly

 

Ensure nothing is obstructing the drawer from closing properly eg sound 
insulation, hoses or drawer latches.

  If a problem occurs, consult the ‘Troubleshooting’ or ‘Fault Codes’ section of 

the User guide.

 

If after checking these points you still need assistance, please refer to the 
Service & Warranty book for warranty details and your nearest Authorised 
Service Centre, or contact us through our website, listed below.

www.fi sherpaykel.com

Important!    

SAVE THESE INSTRUCTIONS

The models shown in this document may not be available in all markets and are subject to change 
at any time. For current details about model and specification availability in your country, please 
visit our website listed at the end of this document or contact your local Fisher & Paykel dealer.

Spray arms

Содержание DD90S(H)TI2 (Integrated)

Страница 1: ...NZ AU GB IE 590202D 04 13 DD90SDF H TX2 DD90SDFTM2 Designer DD90S H TI2 Integrated models INSTALLATION INSTRUCTIONS DishDrawerTM dishwasher...

Страница 2: ...ATION EXTERNAL VENTING MAXIMUM DISTANCE OF HOSES CORD FROM CHASSIS EDGE FOLLOW STEPS FOR THE EXTERNAL VENTING KIT CHOOSE DRAINAGE OPTION INSTALL THE FRONT PANEL FINAL CHECKLIST TROUBLESHOOTING FOLLOW...

Страница 3: ...At the completion of the dishwasher installation the Installer must perform the Final Checklist Remove all packaging materials supplied with the dishwasher This dishwasher is manufactured for indoor u...

Страница 4: ...Paykel Authorised Service Centre or through our local website listed at the end of this document Clamp 1 for securing Drain hose joiner Wire clip 1 for securing Drain hose joiner Phillips 16 mm screws...

Страница 5: ...3b External Venting kit 1 supplied with Integrated models with remote NZ AU only Panel mounting screws 14 Panel bracket 1 attached to product Integrated rectangular badge 1 Satin chrome supplied supp...

Страница 6: ...f chassis to back of front panel 553 553 553 E maximum extension of drawer excl handle 545 5452 5452 F depth of front panel excl handle 18 16 20 16 20 G height1 of chassis 458 458 458 H depth of handl...

Страница 7: ...benchtop 480 480 480 M inside height of cavity 460 min 460 min 460 N inside width of cavity 864 864 864 O overall width of cabinetry 900 900 900 P inside depth of cavity min 560 min 560 min 560 Recomm...

Страница 8: ...withstand moisture 50O C 80 RH Because of it being a hot and wet environment generally the back and sides of the panel should be completely sealed with a waterproof vapour barrier ie polyurethane to...

Страница 9: ...t of panel 9 kg Adequately sealed to withstand moisture 50O C 80 RH Because of it being a hot and wet environment generally the back and sides of the panel should be completely sealed with a waterproo...

Страница 10: ...45 psi Min 0 03 MPa 4 3 psi Important Adjacent cabinetry must not extend above cavity base Important The power outlet must be located in a cabinet adjacent to the dishwasher cavity 220 240 VAC min 7 A...

Страница 11: ...ME CABINET INTEGRATED MODELS WITH REMOTE NZ AU ONLY PREPARATION FOR EXTERNAL VENTING THROUGH ADJACENT CABINET 60 mm 60 mm max 5 mm max 5 mm 220 mm 220 mm 100 mm 100 mm min 100 mm min 100 mm 60mm Servi...

Страница 12: ...only Integrated models only Power cord excl plug 750 mm Power cord excl plug 400 mm Drain hose 1500 mm Inlet hose 37 3 8 950 mm Drain hose 2000 mm Drain hose 1500 mm Inlet hose 1650 mm Inlet hose 950...

Страница 13: ...13...

Страница 14: ...tion of the routing then ensure the venting hose is securely attached to it NOW CHOOSE WHICH INSTALLATION METHOD a or b IS MORE SUITABLE FOR YOUR CABINETRY Clip all four side mounting brackets into th...

Страница 15: ...THE EXTERNAL VENT 2 1 After routing the vent hose through and out the hole cutout attach and secure the vent by tightening the four screws provided Airflow As you push product in pull through hoses an...

Страница 16: ...in pull through hoses and cord ensuring they don t get kinked or twisted Important If product cannot be pushed in far enough pull out again and rearrange hoses and cord Do not use excessive force as...

Страница 17: ...release drawer from runners Push drawer runners back in Product may move Mark chassis position on cavity 5 5 1 2 3 4 100 mm 1 2 2 The product has three pairs of fixing points Ensure the sound insulat...

Страница 18: ...NEL TO PANEL BRACKET 15a 16a Important Useall14screwsprovidedasshown Align bottom of panel with bottom of bracket 1 2 16 mm x14 Electrical Shock Hazard Before continuing ensure that the product is dis...

Страница 19: ...NG To earth the panel bracket connect the earth wire from the product to one of the tabs Any custom metal component e g handle that extends past the rubber door seal must be earthed too Failure to fol...

Страница 20: ...ACKET DISCONNECT BADGE 15b 17b 18b 16b 1 3 4 1 2 1 2 Important Useall14screwsprovidedasshown 1 2 16 mm x14 69mm 457mm 127 mm 255 mm 30 mm 25 mm Electrical Shock Hazard Before continuing ensure that th...

Страница 21: ...ADGE GB IE ONLY INSTALLING THE FRONT PANEL BADGE CONTROLS When refitting the door pins ensure they are orientated as shown WARNING WARNING Connect the integrated badge earth wire to one of the two tab...

Страница 22: ...or down to align the gaps in your cabinetry Repeat on the other side if necessary The panel has a maximum travel of 2 mm up or down Important Integratedmodelswithremotecontrol Ensurethatyoumaintainam...

Страница 23: ...ner 750 882 5 mm 750 882 5 mm min R 200 mm min R 200 mm Supplied drain hose joiner 19 mm waste tee HIGHLOOP min 150 mm Ensure drain hose is routed straight to joiner Remove excess drain hose material...

Страница 24: ...outed correctly No water supply This is displayed as a U1 fault see section If there is a fault in the User guide for how to recognise this fault on models without a display Check water is connected a...

Отзывы: