Hardware Output mode will monitor the power supply current when any (and only) one of the fill valve,
detergent diverter, water softener, wash/drain motor, drying fan is being operated, so do not run combinations of
outputs.
If the current is too high or too low, a fault with a component is present, and the controller will beep with a long
low tone repeated every second.
Different combinations of outputs can be switched on or off together, but the controller will prevent higher
current drawing components such as the wash pump and the lid motors being turned on together.
Press
START/PAUSE
to advance to the next hardware output.
Press
KEYLOCK
to turn the currently displayed output on or off. If the green LED on integrated or blue LED on
designer above start/pause button is displayed, then that output has been switched on, and if it is not displayed
then that output is off.
Press
POWER
to exit at any time (all outputs will be switched off on exit).
The LCD display and touch switch panel LEDs are illuminated to correspond to a particular hardware device. The
following table details the display order of the test.
LCD Heav Norm
Fast
Deli
Rinse Hardware Output
-------------------------------------------------------------------------------------------
bL Off Off Off Off
On
Backlight
Er Off Off Off
On
Off
Element Relay (turns off after 5 seconds)
Ld Off Off Off
On
On
Lid Motors (will run up to 10 seconds)
dd Off Off
On
Off Off Detergent
Diverter
Valve
FU Off Off
On
Off
On
Fill Water Valve
P1 Off Off
On
On
Off
Motor Wash direction 2200-2800 rpm
(will not run if the tub is open)
P2 Off Off
On
On
On
Motor Drain direction 4200 rpm (times out after 255 seconds.)
rd Off
On
Off
Off
Off
Rinse Aid Dispenser (dispenses according to current user setting)
dF Off
On
Off Off
On
Drying fan
LE Off
On
Off
On
Off
Rinse Aid and Salt Tank LEDs
C1 Off
On
Off
On
On
Water Softener Diverter Valve
C2 Off
On
On
Off
Off
Water Softener Brine Pump
C3 Off
On
On
Off
On
Water Softener Brine Valve
A1 Off
On
On
On
Off
Rinse Aid Pump
(operates as a valve for diagnostic purposes only)
o
C Off
On
On
On
On
Displays current water temperature.
o
E
On
Off Off Off Off Displays
controller
rail
voltage
(C3 is used in the factory to empty the water softener before the product is packed.)
WARNING: Take care when running individual components not to overload them. It is advisable to place some
water in the tub before turning the element on.
Tub Home Sensor Test: At any time during HO test mode the Keylock symbol on the LCD display (Keylock LED on
integrated badge) indicates the tub position. On = closed, off = open.
To skip to the next level, press POWER button: