CUTOUT DIMENSIONS
Notes:
z
z
When determining a suitable location, take into account concerns such as exposure to
wind, proximity to traffic paths, and keeping any gas supply lines as short as possible.
z
z
Locate the unit in a well-ventilated area.
z
z
The counter and supporting ledges or deck must be level and flat.
z
z
The enclosure should have ventilation holes to prevent gas build-up in the event of a
leak. Refer to ANSI Z21.58 Standard for Outdoor Cooking Gas Appliances, Section 1.7
Enclosures For Self Contained LP-Gas Supply Systems.
Notes:
z
z
Use only the DCS insulated jacket which has specifically been designed and tested for
this purpose.
z
z
To purchase access doors and drawers, visit dcsappliances.com
z
z
30” access doors model number: ADN1-30
z
z
30” access drawers model number: ADR2-30
CUTOUT DIMENSIONS
BE1-30 MODELS
INCHES
MM
A
Height of cutout
10 1/8
257
B
Depth of cutout
22 3/4
578
C
Width of cutout
28 1/2
724
D
Depth of gas supply opening
4 15/16
125
E
Width of gas supply opening
4
102
CUTOUT DIMENSIONS
BE1-30 MODELS
INCHES
MM
A
Height of cutout
11 1/8
283
B
Depth of cutout
23 3/4
603
C
Width of cutout
34 7/8
886
D
Depth of gas supply opening
4
102
E
Width of gas supply opening
4
102
F
Depth to gas supply opening from front of cutout
18 1/2
470
G
Width to gas supply opening from side of cutout
3 1/2
89
STANDARD CUTOUT
INSULATED JACKET CUTOUT
a
b
c
d
e
a
b
c
e
d
g
f
If the unit is to be placed into a combustible enclosure, an insulated jacket is required.
ventilation
ventilation