PREPARATION OF THE OVEN

VENTILATION SYSTEM

1.  Open the bottom of the carton, remove oven and all packing materials.
2.  CHECK THE OVEN.
 

Check the oven for any damage, such as misaligned or bent door, damaged door seals and 
sealing  surfaces, broken or loose door hinges and latches and dents inside the cavity or 
on the door. If there is  any damage, do not operate the oven and contact your dealer or 
Fisher & Paykel AUTHORIZED SERVICER.

3.  Rest the microwave oven on its side as shown in Figure 6. 
4.  Remove the two screws which secure the mounting plate to the rear side of the oven. 

Remove the mounting plate. The two screws can be discarded.

Note:

 If the unit you purchased does not have the mounting plate attached to the rear side of 

the oven, please disregard this section and continue to Section 8.

 

Mounting plate

Grease filter openings

Figure 6

This Over-the-range microwave oven is designed for adaptation to three types of hood 
ventilation systems. Select the type required for your installation.

A. RECIRCULATING - NON-VENTED, DUCTLESS OPERATION

The unit is shipped assembled for recirculating.

Note:

1.  The Exhaust Damper Assembly (Figure 11) is not required for recirculating operation.
2.  The Charcoal Filter provided with the unit must be installed behind the exhaust louver 

before use. For instructions on installation of the filter, refer to the "Cleaning and Care" 
section in the Use and Care Guide.

3.  The Charcoal Filter should be replaced every 6 to 12 months, depending on use.

B. HORIZONTAL EXHAUST - OUTSIDE VENTILATION

Step

1

Figure 7

 

z

Remove and save the 4 screws from 
Fan Cover Bracket. Remove Fan Cover 
Bracket by sliding it in the opposite 
direction of the arrow on the Fan Cover 
Bracket, as shown in Figure 7.

Step

2

Figure 8

 

z

Lift Hood Fan Unit carefully and slip 
wires out of cavity. See Figure 8.

CAUTION:

DO NOT PULL OR STRETCH BLOWER WIRING.

Содержание CMOH30SS

Страница 1: ...OVER THE RANGE CONVECTION MICROWAVE OVEN CMOH30SS INSTALLATION GUIDE US CA ...

Страница 2: ......

Страница 3: ...rical grounding instructions 5 Hood exhaust duct 5 Tools recommended for installation 6 Installation hardware 6 Preparation of the oven 7 Ventilation system 7 Oven installation 9 Mounting oven to the wall 10 Mounting deflector 11 Check list for operation 11 ...

Страница 4: ...l or plaster lath The mounting surfaces must be capable of supporting weight of 110 pounds the oven and contents AND the weight of all items which would normally be stored in the top cabinet above the unit The unit should be attached to a minimum of one 2 x 4 wall stud To find the location of the studs one of the following methods may be used A Use a stud finder a magnetic device which locates the...

Страница 5: ...onnection procedures Ground Receptacle Opening for Power Cord Figure 3 When the hood is vented to the outside a hood exhaust duct is required All ductwork must be metal absolutely do not use plastic duct Check that all connections are made securely Please read the following carefully Exhaust connection The hood exhaust has been designed to connect to a standard 3 1 4 x 10 rectangular duct If round...

Страница 6: ...carton for protection TOOLS RECOMMENDED FOR INSTALLATION INSTALLATION HARDWARE The INSTALLATION HARDWARE items 1 8 packed with the oven should contain the following ITEM NAME QUANTITY PART CODE 1 Wood Screw 5 x 30 mm 6 290109 2 Toggle Bolt 10 24 x 50 mm 4 290106 3 Top Cabinet Screw 5 x 60 mm 2 290108 4 Flat Washer 30 mm diameter 2 290107 5 Grommet 1 290105 6 Tapping Screw 4 x 12 mm 4 245657 7 Exha...

Страница 7: ...er openings Figure 6 This Over the range microwave oven is designed for adaptation to three types of hood ventilation systems Select the type required for your installation A RECIRCULATING NON VENTED DUCTLESS OPERATION The unit is shipped assembled for recirculating Note 1 The Exhaust Damper Assembly Figure 11 is not required for recirculating operation 2 The Charcoal Filter provided with the unit...

Страница 8: ... screw 4 x 12 mm from the INSTALLATION HARDWARE tighten into place C VERTICAL VENTILATION OUTSIDE VENTILATION Step 1 Fan Cover Bracket Figure 12 z Remove and save the 4 screws from the Fan Cover Bracket Remove Fan Cover Bracket by sliding it in the opposite direction of the arrow on the Fan Cover Bracket as shown in Figure 12 Step 2 Figure 13 z Lift the Hood Fan Unit carefully and slip wires out o...

Страница 9: ...ugh the holes at A B C and D UNLESS THOSE HOLES ARE LOCATED ON THE STUD Insert one Toggle Bolt into A B C and D where appropriate these correspond to the holes of the Wall Template and put the Toggle Nuts onto the Toggle Bolts Figure 17 Refer to instructions in Wall Template Step 3 Wall Space more than wall thickness Figure 18 z Position the Mounting Plate with the Toggle Bolts attached at the wal...

Страница 10: ...he case of a non recessed bottom in the top cabinet the hole for the cord may need to be enlarged Step 3 Unit mounting screw Figure 21 z Tighten the two unit mounting screws located in the grease filter openings See Figure 21 Step 4 Grease filter Figure 22 z Install grease filters by fitting into the opening Push back and up into place See Figure 22 Step 5 Grommet for metal cabinet only D E Figure...

Страница 11: ...ure the deflector with 3 Tapping screws 4 x 12 mm packed in the Installation Hardware 1 Make sure the unit has been installed according to all of the Installation Instructions and the Wall and Top Cabinet Templates 2 Plug in the power cord 3 Keep the use and care guide ...

Страница 12: ...ebsite or contact your local Fisher Paykel dealer Fisher Paykel Appliances 2021 Tous droits réservés Les modèles illustrés dans ce guide peuvent ne pas être disponibles dans tous les pays et sont sujets à modifications sans préavis Les caractéristiques de produit présentées dans ce guide s appliquent aux modèles et produits spécifiques qui y sont décrits à la date de publication Dans le cadre de n...

Отзывы: