CLEARANCES — 450MM MODELS
CLEARANCE DIMENSIONS
CG451D
MM
A
Minimum clearance from top of trivets to:
z
Rangehood
650
z
Overhead exhaust fan
800
z
Downward facing combustible surface*
650
z
Downwards-facing tiled or fire resistant surface
500
B
Minimum clearance below bench top to:
z
Combustible surface
70
z
Fisher & Paykel oven or nearest non-combustible surface
65
C
Minimum clearance from cutout to nearest combustible surface
60
D
Minimum distance from right edge of cooktop to gas connection point on wall
(if using a flexible hose)
250
E
Distance from floor to gas connection point on wall
(if using a flexible hose)
800-850
F
Minimum clearance from countertop to overhead cabinet
(not directly above the cooktop)
450
G
Maximum depth of overhead cabinetry
600
H
Minimum distance between overhead cabinets
(either side of the cooktop)
315
I
Minimum clearance from rear edge of cutout to nearest:
85
z
Combustible surface
85
z
Non-combustible surface
45
J
Minimum clearance from front edge of cutout to counter front
35
A
H
f
f
b
D
E
C
C
g
i
j
*Combustible surface definition
Any materials of a building structure or decorative structure made of wood, compressed paper,
plant fibres, vinyl/plastic or other materials that are capable of transferring heat or being
ignited and burned. Such material shall be considered combustible even though flame-proofed,
fire-retardant treated or surface-painted, or plastered.
Ensure there is an earthed power outlet within 900mm of the centre rear of the product. The gas
connector on the wall should be accessible with the product installed.
16