![Fisher & Paykel CG755 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/fisher-and-paykel/cg755/cg755_installation-instructions-and-user-manual_2295212017.webp)
15
Installation instructions
Leak-testing and flame-testing the cooktop
1
After connecting the gas supply, check the piping and connections for leaks as required by
local regulations. The presence of bubbles indicates a leak. Tighten or replace connections as
appropriate, then re-check for leaks.
Important!
Do not use any naked flame to check for leaks.
2
The operation of the appliance MUST be tested before leaving.
3
Turn on the gas and light each burner. Check for a well-defined blue flame without any yellow
tipping. If any abnormality is evident, check that the burner cap is located properly and the
injector nipple is aligned correctly.
4
Check the minimum burner setting by quickly rotating the burner knobs from the maximum
to the minimum position: the flame must not go out. If adjustment is required, see section
‘Adjusting a burner’s minimum gas rate setting’ following.
5
If satisfactory performance cannot be obtained, check the installation and notify the local gas
supply authority of a gas supply problem, or if it is an appliance problem, our Customer Service
Centre should be called to obtain the nearest authorised Service Agent.