background image

2

1

   SAFETY AND WARNINGS

Do not use or store flammable 

materials on or near this appliance.

Do not spray aerosols in the vicinity of 

this appliance while it is in operation.

Packing elements (eg plastic bags, 

polystyrene foam, staples, packing 

straps etc) and tools should not be left 

around during and after installation, 

especially if they are within easy reach 

of children, as these may cause serious 

injuries.

You must remove the transit screws 

before installing the cooktop.  See step 

8 of installation instructions.

 

Ventilation requirements

The appliance should be installed in 

a room or space with an air supply in 

accordance with BS 5440:2 2009. 

For rooms with a volume of less than 

5 m

3

, permanent ventilation through  a 

free area of at least 100 cm

2

 will be 

required. 

For rooms with a volume between 5 

m

3

 and 10 m

3

, permanent ventilation 

through a free area of at least 50 cm

2

 

will be required, unless the room has 

a door which opens directly to the 

outside air, in which case no permanent 

ventilation is required. 

For rooms with a volume greater than  

10 m

3

, no permanent ventilation is 

required.

IMPORTANT!

  Regardless of room size, all rooms 

containing the appliance must have 

direct access to the outside air via an 

openable window or equivalent. 

Where there are other fuel-burning 

appliances in the same room, BS 

5440-2: 2009 should be consulted to 

determine the correct amount of free 

area ventilation requirements. 

The above requirements also allow for 

use of a gas oven and grill, but you 

need to consult a qualified engineer if 

there are other gas-burning appliances 

in the same room.

Содержание CG604DX

Страница 1: ...Gas Cooktop CG604DX CG905DX models GB IE IN INSTALLATION INSTRUCTIONS 590877A 06 15 www fisherpaykel com...

Страница 2: ......

Страница 3: ...l injury or damage and could invalidate any warranty or liability claims This gas appliance is suitable for connection only to the gas type for which it was set at the factory as declared on the appli...

Страница 4: ...anent ventilation through a free area of at least 100 cm2 will be required For rooms with a volume between 5 m3 and 10 m3 permanent ventilation through a free area of at least 50 cm2 will be required...

Страница 5: ...le should not touch any metal parts If the power supply cable is damaged it is replaced only by the special cable Part no 534994 KIT SPARES TRMNL BLK FLEX 11 obtainable from authorised Fisher Paykel S...

Страница 6: ...ssemblies should be BS 699 1 certified Seal exposed bare edges of the cutout with an oil based paint or moisture proof polyurethane to prevent possible moisture creeping between the cooktop trim and t...

Страница 7: ...1 04 0 70 4 53 3894 LPG 29 mbar Nominal rating g h 0 56 1 23 90 g h 1074 0 75 2 31 169 g h 2020 0 95 3 64 262 g h 3129 0 69 0 69 0 51 4 45 320 g h 3825 Nominal pressure with at least one large burner...

Страница 8: ...rs dials and pan supports 64 64 B Overall width of product 600 900 C Overall depth of product 530 530 D Height of chassis below top of bench 59 59 E Width of chassis 555 856 F Depth of chassis 486 486...

Страница 9: ...resistant surface 650 800 650 500 650 800 650 500 F Minimum clearance below top of benchtop to Combustible surface Fisher paykel oven or nearest non combustible surface 70 65 70 65 G Minimum distance...

Страница 10: ...longenoughtoallowforremovalofcooktopforservicing Makesuretheconnectorislocatedasshowninstep3CLEARANCEDIMENSIONS ThehoseassemblymustbeAS NZS1869ClassBorDcertified withanRp ISO7 1 femalet Thehoseassembl...

Страница 11: ...test point pressure of 20 mbar with all the burners operating at highest setting Ensure the hose is long enough to allow for removal of cooktop for servicing Make sure the connector is located as show...

Страница 12: ...eflamewithoutanyyellowtipping Ifanyabnormalityisevident checkthatthecomponentsoftheburnerassemblyarelocatedproperly Ifproperoperationcannotbeobtained contactyournearestF PAuthorisedServiceCentre Theco...

Страница 13: ...mbination Check for a well defined blue flame without any yellow tipping If any abnormality is evident check that the components of the burner assembly are located properly If proper operation cannot...

Страница 14: ...correct working pressure Have you affixed the supplied duplicate data plate label on an adjacent surface accessible to the customer Is the cooktop earthed Check that the power supply cord is NOT touch...

Страница 15: ...13...

Страница 16: ...tions in this booklet apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should...

Отзывы: