
7
Installation instructions
Clearances
(mm)
C
G604
C
G905DWFC
C
G905DW
A
C
A
minimum clearance from left edge of cutout to:
nearest combustible surface
140
140
100
B
minimum clearance from right edge of cutout to:
nearest combustible surface
140
140
100
C
minimum clearance from rear edge of cutout to:
nearest combustible surface
nearest non-combustible surface
110
20
110
30
115
35
D*
minimum height of non-combustible material when used on
adjacent walls
150
150
150
E
minimum clearance from pan supports to:
rangehood
any other overhead exhaust fan
downward-facing combustible surface (overhead cabinetry)
downward-facing tiled or fi re-resistant surface
650
800
650
500
650
800
650
500
650
800
650
500
F
minimum clearance below top of benchtop to:
nearest combustible surface
F&P oven or nearest non-combustible surface
60
60
60
60
81
81
G
Ensure there is an earthed power outlet within 900 mm of the rear right-hand corner of the cook-
top. The outlet should be accessible with the cooktop installed.
H
If connecting the cooktop to the gas supply with a fl exible hose, the connector on the wall should
be between 800-850 mm above the fl oor and to a distance of at least 250 mm outside the width
of the cooktop. The connector should be accessible with the cooktop installed.
*
See section ‘Standards requirements’ following.
C
E
A
F
B
G
H
D