SAFETY AND WARNINGS

1

 

IMPORTANT SAFETY INSTRUCTIONS! 

 

This appliance shall be installed in accordance with the installation requirements of the local 
gas authority or the appropriate installation code or in the absence of local codes with the latest 
National Fuel Gas Code NFPA 54/ANSI Z223.1 or CAN/CSA B149.1,2 (Canada). Local building and 
electrical codes must be adhered to.

 

Electrical installation must be in accordance with the National Electrical Code, ANSI/NFPA70 - latest 
edition or CSA C22.1 (Canada) and/or local codes.

 

Installation in manufactured (mobile) home: installation must conform with the Manufactured Home 
Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Standard for Mobile 
Home Construction and Safety, Title 24, HUD (Part 280)] or, when such standard is not applicable, the 
Standard for Manufactured Home Installations, ANSI/NFPA 225, or with local codes where applicable.

 

Installation in Recreational Park Trailers: installation must conform with state or other codes or, in 
the absence of such codes, with the Standard for Recreational Park Trailers, ANSI A119.5.

 

WARNING!

   

   Cut 

hazard

 

Take care - panel edges are sharp.

 

Failure to use caution could result in injury or cuts.

 

WARNING!

   

 

 

Electrical shock hazard

 

Disconnect product from the mains power supply before servicing. This

 

appliance is equipped with a three-prong grounding plug for your

 

protection against shock hazard and should be plugged directly into a

 

properly grounded power outlet. Do not under any circumstances cut or

 

remove the grounding prong from this plug. 

 
 

Failure to follow this advice may result in electrical shock or death.

 

Do not remove permanently affixed labels, warnings, or plates from the product. This may void the 
warranty.

 

Flexible appliance connectors shall meet the requirements of ANSI Z21.24 and State Boards. They 
shall not exceed 35 ½

   inches (900 mm) in length. In order to avoid hazard, these appliances must be 

installed according to these instructions.

 

This appliance must be installed by an authorized person (Warning: this appliance must be installed 
by a licensed plumber or gas fitter when within the Commonwealth of Massachusetts).

 

Please make this information available to the person installing the appliance as it could reduce your 
installation costs.

 

Please leave these instructions with the appliance. Inform the customer to retain for future reference 
and for the local inspectors’ use.

 

Failure to install the appliance correctly could invalidate any warranty or liability claims.

 

Leak testing of the appliance shall be conducted according to the manufacturer’s instructions.

 

Only genuine replacement parts may be used for servicing the appliance. These are available from 
your nearest Fisher & Paykel Service Center.

 

Before you install the appliance, please make sure that

 

 

the local distribution conditions (nature of gas and pressure) and the adjustment of the appliance 
are compatible. For adjustment conditions for this appliance, see ‘Gas rate summary’ under step 3. 

 

a suitable isolating switch is incorporated in the fixed wiring in an acceptable position.

 

the appliance is connected to a power outlet that is electrically grounded in accordance with local 
codes or in the absence of local codes, with the National Electric Code ANSI/NFPA 70 or CSA C22.2 
(Canada).

 

there is a power outlet (110-120V 60Hz) within reach of the appliance cable (35 1/2” (900 mm) from 
the center rear of the appliance). This must be accessible after installation. The mains power supply 
cable should not touch any metal parts.

 

the countertop is square and level and no structural members interfere with space requirements

 

the countertop is made of heat-resistant material.

 

you take note of the following recommended non-combustible materials: ¼” (6 mm) flame retardant 
millboard covered with not less than No. 28 MSG sheet steel, 1/32” (0.4 mm) stainless steel, 

 

1/32” (0.6 mm) aluminum or 1/32” (0.5 mm) copper.

 

the gas shut-off valve is accessible after installation.

 

if the power supply cable is damaged, it is replaced only by the special cable: Part no. 531954 – Flex 
Terminal Block Assy US, obtainable from authorized Fisher & Paykel Service Agents.

Содержание CG365D

Страница 1: ...US CA 590486B 08 13 CG365D models Gas cooktop INSTALLATION INSTRUCTIONS...

Страница 2: ...ctions This appliance must be installed by an authorized person Warning this appliance must be installed by a licensed plumber or gas fitter when within the Commonwealth of Massachusetts Please make t...

Страница 3: ...ment 3 GAS RATE SUMMARY CG365D SEMI RAPID SEMI RAPID RAPID DUAL WOK AUX US CA Injector orifice mm Nominal rating BTU hr Injector orifice mm Nominal rating BTU hr Injector orifice mm Nominal rating BTU...

Страница 4: ...below top of counter 2 5 16 59 E width of chassis 33 11 16 856 F depth of chassis 19 1 8 486 G overall width of cutout 34 1 16 865 H overall depth of cutout 19 5 16 490 I corner radius of cutout max 3...

Страница 5: ...mum overall depth of overhead cabinetry 13 330 G minimum distance between overhead cabinets installed to either side of product 36 915 H minimum vertical distance between counter and cabinet extending...

Страница 6: ...nut Fibre washer Foam Tape Adhesive side Ensure edge of tape lines up with outer edge of cooktop 1 Turn the cooktop upside down and place it on a soft surface 2 Spread the seal around the edges with...

Страница 7: ...7 11 SECURE TO COUNTERTOP x4 Repeat on all the other sides 10 FIT CLAMPING BRACKETS BASED ON THE CounterTOP THICKNESS 1 16 20mm 20 30mm 1 1 30 40mm 1 40mm x4 view from below view from below...

Страница 8: ...t off valve must be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance In Massachusetts such shut off devi...

Страница 9: ...kPa Minimum gas supply pressure for regulator testing 5 W C Natural Gas 12 W C LP Gas After installing the gas supply and making all connections check thoroughly for possible leaks 1 Turn all control...

Страница 10: ...eck that the ignition system operates correctly light each burner by itself then all burners in combination Check for a well defined blue flame without any yellow tipping If any abnormality is evident...

Страница 11: ...y set for NG or LP matches the type of gas at the site of installation Have you used the fibre washer supplied Have you leak tested all connections Is the cooktop set to the correct working pressure H...

Страница 12: ...US CA 590486B 08 13 Mod les CG365D Surface de cuisson au gaz INSTRUCTIONS D INSTALLATION...

Страница 13: ...tre install par un monteur d installation au gaz ou plombier autoris Remettez ces instructions la personne qui installera l appareil Cela pourrait r duire vos co ts d installation Laissez ces instruc...

Страница 14: ...qu e l arri re de ce document 3 TABLEAU DE D BIT DES GAZ CG365D SEMI RAPIDE SEMI RAPIDE RAPIDE DOUBLE POUR WOK AUXILIAIRE US CA Orifice d injection mm Valeur nominale BTU heure Orifice d injection mm...

Страница 15: ...po 59 E largeur du ch ssis 33 11 16 po 856 F profondeur du ch ssis 19 1 8 po 486 G largeur hors tout de l ouverture 34 1 16 po 865 H profondeur hors tout de l ouverture 19 5 16 po 490 I rayon du coin...

Страница 16: ...le des armoires suspendues 13 po 330 G distance minimale entre les armoires suspendues install es des deux c t s du produit 36 po 915 H distance verticale minimale entre le comptoir et une armoire au...

Страница 17: ...lle en fibre 1 Retournez la surface de cuisson l envers sur une surface douce 2 Appliquez le joint autour des rebords en pla ant le c t adh sif vers le bas pour obtenir un joint continu autour de la s...

Страница 18: ...COMPTOIR x4 R p tez sur tous les autres c t s 10 INSTALLEZ LES SUPPORTS DE RETENUE EN LES AJUSTANT L PAISSEUR DU COMPTOIR 5 8po po po 13 16po 16 20mm 20 30mm 13 16po 1 po 30 40mm 1 po 40mm x4 view fr...

Страница 19: ...aturel 12 po 305 mm de colonne d eau pour le gaz de p trole liqu fi Vous devez installer un robinet d arr t manuel dans un endroit accessible de la canalisation externe de l appareil pour pouvoir ouvr...

Страница 20: ...onne d eau pour le gaz naturel 12 po 305 mm de colonne d eau pour le gaz de p trole liqu fi Une fois l installation de l alimentation en gaz et tous les raccordements effectu s v rifiez soigneusement...

Страница 21: ...ue le syst me d allumage fonctionne correctement allumez chaque br leur individuellement puis tous les br leurs simultan ment V rifiez si l appareil produit une flamme bleu clair bien d finie sans poi...

Страница 22: ...ole liqu fi GPL correspond au type de gaz disponible sur le site d installation Avez vous utilis la rondelle en fibre fournie Avez vous v rifi tous les raccords pour d celer d ventuelles fuites La sur...