background image

FINAL CHECKLIST

  

TO BE COMPLETED BY THE INSTALLER

  

Have you installed the clamping brackets?

  

Have you allowed for adequate air supply to the product?

  

Have you leak-tested all connections?

  

Is the regulator set to the correct working pressure (4” H

2

O NG/11” H

2

O LP)?

  

Have you placed the supplied duplicate data plate on an adjacent surface?

  

Is the CookSurface grounded?

  

Check that the power supply cable is NOT touching the CookSurface.

  
  
  

OPERATION: 

  

Do all burners ignite both individually and in combination?

  

Are the flames consistent and appropriately sized?

  

Have you demonstrated the basic operation to the customer?

 

   

For replacement parts or if further help is needed concerning this appliance call:

 

   

Toll Free 1 888 9 FNP USA 

(1 888 936 7872)

 

   

or write to:

 
 

   

Fisher & Paykel Appliances Inc.

 

   

5900 Skylab Road 

 

   

Huntington Beach, CA  92647

 

   

USA

 

   

or contact us through our web site, 

 

   

www.fisherpaykel.com

Installer’s name:

Installer’s signature:

Installation company:

Date of installation:

   

LEAVE THESE INSTRUCTIONS WITH THE CUSTOMER

9

(2,1)  -2- 599648B izonaCG363cs installA2USCA.indd 4/5/09 11:15:08 AM

(2,1)  -2- 599648B izonaCG363cs installA2USCA.indd 4/5/09 11:15:08 AM

Содержание CG363MLNGB1

Страница 1: ...in length In order to avoid hazard these appliances must be installed according to these instructions This appliance must be installed by an authorized person Warning this appliance must be installed...

Страница 2: ...verhead cabinetry 13 330 13 330 G minimum distance between overhead cabinets installed to either side of product 36 915 36 915 H minimum vertical distance between counter and cabinet extending above t...

Страница 3: ...e regulator must be disconnected from the gas supply piping system during any pressure testing of that system in excess of p s i 3 5 kPa The appliance must be isolated from the gas supply piping syste...

Страница 4: ...f routered recess max 1 16 2 max 1 16 2 N height of routered recess 3 16 5 3 16 5 M K L M N J 1 1 2 2 3 16 5 mm 2 20 50 mm 3 min 300O F 150O C rated TO REMOVE PRODUCT x4 1 2 A B C D F E WARNING We do...

Страница 5: ...not be restricted The ventilation area must be 20 x 2 500 x 50 mm or of an equivalent area If the 2 50 mm wide slot is not possible due to the width of the available toe recess increase the length of...

Страница 6: ...GAS LEAKS AND TEST A GAS ON B C C 4 H2 O NG or 11 H2 O LP Test operation by lighting all burners 8 10 B B B 1 2 2 599648B izonaCG363cs installA2USCA indd 4 5 09 11 15 08 AM 1 2 2 599648B izonaCG363cs...

Страница 7: ...ndividually and in combination Are the flames consistent and appropriately sized Have you demonstrated the basic operation to the customer For replacement parts or if further help is needed concerning...

Страница 8: ...www fisherpaykel com www fisherpaykel ca 599648B US CA 05 09 2 2 2 599648B izonaCG363cs installA2USCA indd 4 5 09 11 15 08 AM 2 2 2 599648B izonaCG363cs installA2USCA indd 4 5 09 11 15 08 AM...

Отзывы: