1 | Safety guidelines

FISCHER Mess- und Regeltechnik GMBH

4/24

BA_EN_ME11

1 Safety guidelines

1.1 General

This operating manual contains basic instructions for the installation, operation
and maintenance of the device that must be followed without fail. It must be
read by the installer, the operator and the responsible specialist personnel be-
fore installing and commissioning the device.

This operating manual is an integral part of the product and therefore needs to
be kept close to the instrument in a place that is accessible at all times to the re-
sponsible personnel.

The following sections, in particular instructions about the assembly, commis-
sioning and maintenance, contain important information, non-observance of
which could pose a threat to humans, animals, the environment and property.

The instrument described in these operating instructions is designed and manu-
factured in line with the state of the art and good engineering practice.

1.2 Personnel Qualification

The instrument may only be installed and commissioned by specialized person-
nel familiar with the installation, commissioning and operation of this product.

Specialized personnel are persons who can assess the work they have been
assigned and recognize potential dangers by virtue of their specialized training,
their skills and experience and their knowledge of the pertinent standards.

1.3 Risks due to Non-Observance of Safety Instructions

Non-observance of these safety instructions, the intended use of the device or
the limit values given in the technical specifications can be hazardous or cause
harm to persons, the environment or the plant itself.

The supplier of the equipment will not be liable for damage claims if this should
happen.

1.4 Safety Instructions for the Operating Company and the

Operator

The safety instructions governing correct operation of the instrument must be
observed. The operating company must make them available to the installation,
maintenance, inspection and operating personnel.

Dangers arising from electrical components, energy discharged by the medium,
escaping medium and incorrect installation of the device must be eliminated.
See the information in the applicable national and international regulations.

Please observe the information about certification and approvals in the Tech-
nical Data section.

1.5 Unauthorised Modification

Modifications of or other technical alterations to the instrument by the customer
are not permitted. This also applies to replacement parts. Only the manufacturer
is authorised to make any modifications or changes.

Содержание ME11 Series

Страница 1: ...Operating manual ME11 Pressure Transmitter 09005184 BA_EN_ME11 Rev ST4 B 04 22 09005184...

Страница 2: ...y other form print photocopy microfilm or another process without the written consent of the company FISCHER Mess und Regeltechnik GmbH Bad Salzuflen Reproduction for internal use is expressly allowed...

Страница 3: ...ctogram explanation 5 2 Product and functional description 6 2 1 Intended use 6 2 2 Product summary 6 2 3 Function diagram 7 2 4 Design and mode of operation 7 3 Installation and assembly 8 3 1 Genera...

Страница 4: ...s the work they have been assigned and recognize potential dangers by virtue of their specialized training their skills and experience and their knowledge of the pertinent standards 1 3 Risks due to N...

Страница 5: ...ompany is responsible for ensuring that all required mainten ance inspection and installation work is carried out by qualified specialized per sonnel 1 8 Pictogram explanation DANGER Type and source o...

Страница 6: ...essive media because the unit needs to be adapted for the specific customer in terms of the parts that come into contact with the media The device may only be used for the purpose stipulated by the ma...

Страница 7: ...suring range Electr Output Operating voltage Prod no Silicone free Fig 3 Nameplate 2 3 Function diagram Pressure p R R U I U b out 1 2 3 4 5 Fig 4 Function diagram 1 Ceramic sensor 2 electronics 3 Aux...

Страница 8: ...tion however any installation posi tion is possible To guarantee safe working conditions during installation and maintenance suit able stop valves must be fitted in the system see accessories By means...

Страница 9: ...ape U shape G ca 180 20 56 155 ca 200 G G ca 275 ca 130 20 56 G AF27 Manometer connection Connection spigot according to DIN EN 837 1 Fig 6 Siphon MZ1 The transmitter must be positioned below the meas...

Страница 10: ...1 Manometer connection Fig 8 Damping reactor MZ410 3 3 Electrical connections By authorized and qualified specialized personnel only When connecting the unit the national and international electro te...

Страница 11: ...w connection M16x1 5 Seal NBR Contact insert Housing Screw 1 2 3 Line socket Flanged connector Fig 11 Line socket DIN EN 175 301 803 A Ter minal Signal name DC Cable colour 1 Supply Output Ub Sig red...

Страница 12: ...utput Sig Black Table 4 3 wire connection 0 10V 3 4 Commissioning All electrical supply operating and measuring lines and the pressure connec tions must have been correctly installed before commission...

Страница 13: ...evices should be sent directly to our repair department Please coordinate all shipments with our sales department WARNING Process media residues Process media residues in and on dismantled devices can...

Страница 14: ...0 2500 kPa 100 bar 150 bar 0 40 bar 0 4000 kPa 100 bar 150 bar 0 60 bar 0 6000 kPa 200 bar 250 bar Vacuum and measuring ranges Measuring range Pressure safety SI unit Overpres sure Bursting pressure 1...

Страница 15: ...5 W VA 5 6 Operating conditions Ambient temperature range 0 C 60 C Storage temperature range 20 C 85 C Medium temperature range 0 C 85 C EMC EN 61326 1 2013 EN 61326 2 3 2013 RoHS EN 50581 2012 Type...

Страница 16: ...EN_ME11 5 7 Construction design 5 7 1 Standard casing dimensional drawing All dimensions in mm unless otherwise stated M12 x 1 72 38 5 28 SW27 91 20 3 G 6 17 5 13 2 5 G 9 5 20 18 NPT EXT SW27 Schrader...

Страница 17: ...th external thread 5 7 3 Electrical connections Fig 14 Line socket DIN EN 175 301 803 A Unit connector and cable socket DIN EN 175 301 803 Form A 4 pin 1 3 2 1 2 3 Line socket Device plug 1 2 2 Wire 3...

Страница 18: ...5 6 7 8 9 10 11 12 3 4 Code no Measurement accuracy 1 2 Measuring range 01 0 0 6bar 02 0 1bar 03 0 1 6 bar 04 0 2 5 bar 05 0 4bar 06 0 6bar 07 0 10bar 08 0 16bar 09 0 25bar 10 0 40bar 11 0 60bar 31 1...

Страница 19: ...B 4 20 mA DC 2 Wire 24V DC C 0 10 V DC 3 Conductor 24 V AC DC 7 Electrical connection H 4 pin standard plug DIN EN 175 301 803 A M 4 pin M12 plug connection DIN EN 61076 2 101 8 Operating voltage 9 24...

Страница 20: ...11 6 1 Prefabricated connection lines Order no Designation No of Poles length 06401993 PUR cable with M12 coupling 4 pin 2m 06401994 PUR cable with M12 coupling 4 pin 5m 06401563 PUR cable with M12 co...

Страница 21: ...FISCHER Mess und Regeltechnik GMBH Attachments 7 BA_EN_ME11 21 24 7 Attachments Fig 16 CE_EN_ME11...

Страница 22: ...7 Attachments FISCHER Mess und Regeltechnik GMBH 22 24 BA_EN_ME11 Fig 17 UKCA_EN_ME11...

Страница 23: ...FISCHER Mess und Regeltechnik GMBH BA_EN_ME11 23 24 Notes...

Страница 24: ...lefelder Str 37a D 32107 Bad Salzuflen Tel 49 5222 974 0 Fax 49 5222 7170 www fischermesstechnik de info fischermesstechnik de Technische nderungen vorbehalten Subject to technical changes Sous r serv...

Отзывы: