accident  prevention  regulations  and  also  in  the  in-
dustry  guidelines  issued  by  the  DVWG,  GL,  etc. 
and the VDE as well as the local EVUs.  

The  instrument  must  be  decommissioned  and  se-
cured  against  inadvertent  re-operation if  a  situation 
arises in which it must be assumed that safe opera-
tion is no longer possible. Reasons for this assump-
tion could be: 

• 

evident damage to the instrument 

• 

failure of the electrical circuits 

• 

long storage in temperatures over 85°C 

• 

considerable strain due to transport  

Repairs may be carried out by the manufacturer on-
ly. 

A  professional  single  conformity  inspection  as  per 
DIN  EN  61010,  section  1,  must  be  carried  out  be-
fore  the  instrument  can  be  re-commissioned.  This 
inspection must be performed at the manufacturer's 
location.  Correct  transport  and  storage  of  the  in-
strument are required.  

1.5 

Unauthorised Modification 

Modifications of or other technical alterations to the 
instrument  by  the  customer  are  not  permitted. This 
also  applies  to  replacement  parts.  Any  modifica-
tions/alterations  required  will  be  carried  out  by 
Fischer Mess- und Regeltechnik GmbH only.  

1.6 

Impermissible modes of operation 

The  operational  safety  of  this  instrument  can  only 
be  guaranteed  if it is  used  as intended. The instru-
ment  model  must  be  suitable  for  the  medium  used 
in the system. The limit values given in the technical 
data may not be exceeded. 

1.7 

Safe working practices for mainte-
nance and installation work 

The safety instructions given in this operating man-
ual,  any  nationally  applicable  regulations  on  acci-
dent prevention and any of the operating company's 
internal  work, operating and safety  guidelines must 
be observed. 

The  operating  company  is  responsible  for  ensuring 
that all required maintenance, inspection and instal-
lation  work  is  carried  out  by  qualified  specialized 
personnel. 

1.8 

Explanation of symbols 

 

WARNING! 

…  indicates  a  potentially  dangerous 
situation,  non-observance  of  which 
could  endanger  persons,  animals,  the 
environment or objects. 

 

 

 

INFORMATION! 

…  highlights  important  information  ef-
ficient and smooth operation. 

 

 

 

TIP! 

… indicates recommendations that are 
not  specifically  necessary  in  certain 
situations but which could be useful. 

 

 

Application purpose 

Electronic  manometer  for  measuring  over-pressure 
and under-pressure of fluid and gas-like measuring 
substances. The device is to be exclusively used for 
the  applications  agreed  between  the  manufacturer 
and the user. 

Explosion hazard area classification 

The  digital  manometers  ME01  are  suitable  for  use 
as  'Electrical  equipment  for  use  in  areas  with  com-
bustible gases', zone 2. 

Designation as per guideline 2014/34/EU 

 II 3G Ex nA IIC T4 

Product and function description 

3.1 

Design and mode of operation 

A  ceramic  measuring  cell  acts  as  the  pressure 
transducer. The high resistance of the ceramic ma-
terials  that are  used  allow  use  even  for  aggressive 
media.  There  is  a  resistance  measuring  bridge  at-
tached to the side of the measuring diaphragm that 
faces away from the medium. When pressure is ex-
erted, the  membrane distorts  in  the  elastic  range.  t 
the  same  time,  the  resistance  values  of  the  bridge 
change  proportionally  to  the  measuring  pressure. 
These  values  are  implemented  and  displayed  by 
the  installed  electronics.  There  are  electrical  uni-
form  signals  0/4…20 mA  and  0…10  V  in  a  3-wire 
system available for remote transmission. 

Содержание Me01 Series

Страница 1: ...nd operation of this product Specialized personnel are persons who can assess the work they have been assigned and recognize potential dangers by virtue of their specialized train ing their skills and...

Страница 2: ...e operating company s internal work operating and safety guidelines must be observed The operating company is responsible for ensuring that all required maintenance inspection and instal lation work i...

Страница 3: ...afe operation of the in strument the supply circuit must satisfy the requirements for zone 2 category 3 and the locally applicable regulations and guidelines for the installation and operation of elec...

Страница 4: ...nst impacts It may only be transported in packaging specifically intended for transport 8 Service All defective or faulty devices should be sent direct ly to our repair department We would ask you to...

Страница 5: ...y Only CE compliant power supply units with a slow 200 mA fuse may be used Rated voltage 24V DC Allowed operating voltage Ub 15 30 V DC inner effective capacity Ci max 270nF effective inner inductivit...

Страница 6: ...12 Dimensional drawings all dimensions in mm unless otherwise specified M16 x 1 5 Manometer connection port G1 2 nach DIN EN 837 SW22...

Страница 7: ...urement accuracy Characteristic curve dev Relative pressure 1 0 M Characteristic curve dev Absolute pressure 1 0 S Discharge port Connection ports with external thread G B bottom Stainless steel 8 7 E...

Страница 8: ...change without notice Changements techniques sous r serve Fischer Mess und Regeltechnik GmbH Bielefelder Str 37a D 32107 Bad Salzuflen Tel 49 5222 9740 Fax 49 5222 7170 eMail info fischermesstechnik...

Отзывы: