Seite/Page 34 Grundlagen_deu.R01 - Kapitel/Chapter 3:
10.5.11
3.2.5 Transport and Loading/Unloading
3.2.6 Transporting the generator
• The generator must always be upright for transport.
• For transport, the Fischer Panda Transport Box shall be used for the generator. The generator shall be securely
attached to the bottom of the box.
• For loading/unloading, an adequate industrial truck shall be used.
• Depending on the transport distance (e.g. air cargo), the generator fluids (coolant, engine oil, fuel) may have to be
drained. The corresponding instructions and warnings must be fitted to the transport packaging.
3.2.7 Loading/unloading of the generator
For loading/unloading the generator, appropriate ring eye bolts shall be installed in the holes in the support rails. The
load bearing capacity of each ring eye bolt must at least equal the generator weight.
Fig. 3.2-1: Lifting yoke (example)
An adequate lifting yoke shall be used for transport/loa-
ding
3.3
Special Service Instructions and Measures for Extended Machine
Downtimes and Decommissioning
Downtimes are categorised in the following groups:
• Short downtime (1 to 3 months)
• Medium term downtime / hibernation (3 to 6 months)
• Extended downtime / decommissioning (more than 6 months)
3.3.1 Instructions for the starter battery for extended downtimes
Note:
Starter batteries
Self-discharge of batteries is a physical and chemical pro-
cess and cannot be avoided even if the battery is
• For extended downtimes, the battery shall be disconnected from the genset.
Содержание 22-4 HD PVMV-N
Страница 8: ...Seite Page 8 Kapitel Chapter 2 10 5 11 12 Measurements 153 12 1 Hole pattern 153 ...
Страница 25: ...General Instructions and Regulations 10 5 11 Chapter 1 General Instructions and Regulations Page 25 ...
Страница 52: ...Seite Page 52 10 5 11 Leere Seite Intentionally blank The Panda Generator ...
Страница 94: ...Seite Page 94 Panda 8000 42NE PVMV N R01 10 5 11 Leere Seite Intentionally blank Maintenance Instructions ...
Страница 154: ...Seite Page 154 Panel Generator Control P6 RE0703_Kunde_eng R06 1 10 5 11 Leere Seite Intentionally blank Measurements ...