Installation Instructions
10.6.16
Kapitel/Chapter 5: Installation Instructions - Seite/Page 63
5.9.3.7 Installation location for generators of the PVK-UK series
Generators of the PVK-UK series are designed for lateral installation on the vehicle chassis
Please note:
• Min. distance between radiator and vehicle chassis must be 1/2 B.
• Min. distance to gas exhaust (heat and dirt source): 500 mm.
• The exhaust flow area must be unobstructed. No impairment to the vehicle chassis or installations.
Fig. 5.9.3.7-1: PVK-UK installation location
5.9.4 Coolant hoses
• The diameter of the coolant hoses must be equal to or greater than the diameter of the generator connections.
• A vacuum-tight and temperature resistant hose (min. 120 °C) must be used.
• The hoses must be pressure resistant under vacuum conditions.
• Depending on the application location, the hoses must be UV resistant.
• The hoses must be weather resistant and chemical resistant (resistant to oil, etc.).
• The bending radii of the hose type shall be taken into account.
• The hoses must have a general operating permit (ABE) / approval certificate.
5.9.5 Connection of the external radiator
Содержание 12000x PVMV-N
Страница 10: ...Seite Page 10 Kapitel Chapter 1 10 6 16 Leere Seite Intentionally blank ...
Страница 96: ...Installation Instructions Seite Page 96 Kaptitel Chapter 5 Installation Instructions 10 6 16 ...
Страница 148: ...Seite Page 148 Kapitel Chapter 9 Appendix 10 6 16 Leere Seite Intentionally blank Appendix ...
Страница 149: ...Panda_xControl_eng R01 5 10 6 16 Panda xControl Manual ...
Страница 189: ...Panda xControl 10 6 16 Kapitel Chapter 11 Panda xControl Seite Page 189 ...
Страница 190: ...Seite Page 190 Kapitel Chapter 11 Panda xControl 10 6 16 Leere Seite Intentionally blank Panda xControl ...