5.2.3 Advice for optimal sound insulation
Fig. 5.2.3-1: Generator base
The convenient base consists of a stable framework, on
which the generator is fastened by means of shock-
mounts. Since the aggregate is „free“ downwards, the
combustion air can be sucked in unhindered. In addition
the vibrations are void which would arise with a closed
capsule base.
5.3
Generator Connections
All electrical wires are connected within the capsule tightly to the motor and the generator. This is also the case for
fuel lines and cooling water lines.
The electrical connections MUST be carried out according to the respective valid regulations. This also
concerns used cable materials. The cable supplied is meant for laying „protected“ (i.e. in pipe) at a
temperature up to a max of. 70 °C (160 °F). The on-board circuit must also be fitted with all essential fuses.
ATTENTION!
Before working (installation) on the System read the
section „Safety Instructions“ in this manual.
Fig. 5.3-1:
Connection at the Generator - sample
1. Connection for external ventilation valve
2. Connection for external ventilation valve
3. Feed line from external expansion tank
4. Bleeding line to external expansion tank
5. Exhaust out
6. Fuel return line
7. Fuel feed line