General Instructions and Regulations
Seite/Page 18 - Kaptitel/Chapter 1: General Instructions and Regulations
23.3.18
1.6.1.5 Safety instructions concerning cables
Cable types
It is recommended to use cables that are in compliance with the standard UL 1426 (BC-5W2) with type 3 (ABYC
section E-11).
Cable cross-section
The cable shall be selected taking into account the amperage, cable type, and conductor length (from the positive
power source connection to the electrical device and back to the negative power source connection).
Cable installation
It is recommended to install a self-draining cable conduit classified as V-2 or higher in compliance with UL 94 in the
area of the cable guide inside the capsule. It must be ensured that the cable guide is not routed along hot surfaces
such as the exhaust manifold or the engine oil drain screw but instead is installed free from any influence due to
friction and crushing.
1.6.2 General safety instructions for handling batteries
These instructions shall apply in addition to the instructions of the battery manufacturer:
• While you are working on the batteries, a second person should be within earshot to help you if
necessary.
• Keep water and soap ready in case battery acid is burning your skin.
• Wear eye protection and protective clothing. Do not touch your eyes while handling batteries.
• If you have acid splashes on the skin or clothing, wash them out with lots of water and soap.
• If acid sprays into your eyes, immediately flush them with clean water until no more burning is felt.
Immediately seek medical assistance.
• Do not smoke near the batteries. Avoid naked fire. The area around batteries is a potentially explosive
atmosphere.
• Ensure that no tools are dropped on the battery terminals; cover them as necessary.
• Do not wear jewellery or watches on your arms during installation that might short-circuit the battery.
Otherwise, there is a risk of skin burns.
• Protect all battery contacts against accidental contact.
• For battery banks: Use only deep cycle batteries. Starter batteries are not suitable. Lead-acid gel batteries
are recommended. They are maintenance-free, cycle stable, and do not release gases.
• Never charge a frozen battery.
• Avoid battery short-circuits.
• Ensure proper ventilation of the battery to vent gases that may be released.
• Battery connection terminals must be checked for proper seating before operation.
• Battery connection cables shall be installed with utmost care and shall be checked for excessive heating
under load. Check the battery near vibrating components regularly for chafing and insulation defects.
ATTENTION! For battery charger generators (Fischer Panda AGT-DC)!
Prior to installation, verify that the voltage of the battery bank complies with the output voltage of
the generator.