First DTC 200/2G Скачать руководство пользователя страница 7

7

FIRŠT-ROTOTEHNIKA, s.p., Radegunda 54, SI-3330 Mozirje, Slovenija

tel. +386 3 898 35 00, fax. +386 3 898 35 35, e-mail: [email protected], http://www.rototehnika-sp.si

DTC 200/2G

2.5 EXAMPLES OF USE
example: 4

Heating water with solid fuel boiler. When there is not enough
energy, the water in storage tank is after-heated by el. heater.

Electric connection for example 4 and 5

example: 5

Heating sanitary water by central heating water. When energy
of central heating water is too low, the water in storage tank is
after-heated by el. heater.

Jumper position

> HEATING <

This action causes activity for only one heating source. They
never work at the same time. Priority has pump for solar heating.
If there is not enough solar energy, el. heater heats water.

WARNING:

In this way of use, the LED indicator does not show working
of el. heater.
It shows only need for heating sanitary water.

For this way of use, you have to cut jumper, which is shown on
lower picture.

7 (2W) - Electric motor actuated ball valve

EMV 110..series 602, 502

Содержание DTC 200/2G

Страница 1: ...1 Basics 1 2 Operation 1 3 Sensors installation 1 4 Electrical connection 4 1 5 Examples of use 2 HEATINGTHEDOMESTICHOTWATERFROMONEHEATING SOURCE SOLAR COLLECTORS BOILERS HEAT PUMP WITHADDITIONALHEATI...

Страница 2: ...gime Temperature diference setting 0K 15K Hysteresis of thermostat 1K 2K Temperature of ambient 0 C 40 C Outputs 2 relay outputs 230V 50Hz 6 1 A working contact SPST controlling the electric motor act...

Страница 3: ...Heating sanitary water with possibility to control the burner Cooling living space with blowing the cool outside air into the living space If it s used for heating the jumpers must be in position sun...

Страница 4: ...ng source burner The thermostat enables setting of two parameters 1 Regulation of maximum temperature in hot water tank from 5 to 85 C This temperature is defined by T2 sensor witch is generally mount...

Страница 5: ...nnection for example 3 7 2W Electric motor actuated ball valve EMV 110 series 602 502 Jumperposition HEATING 1 5 EXAMPLES OF USE example 1 Heating sanitary water with solar collectors example 2 Heatin...

Страница 6: ...ion you define how much the value of the source temperature collector boiler should exceed the temperature of water around the exchanger in hot water tank that the thermostat opens the valve and activ...

Страница 7: ...by central heating water When energy of central heating water is too low the water in storage tank is after heated by el heater Jumperposition HEATING This action causes activity for only one heating...

Страница 8: ...w much the value of the source temperature outside air should be lower than inside temperature that thermostat switches on the ventilator 3 2 OPERATION DTC 200 2G single differential thermostat measur...

Отзывы: