7
Do not elevate overflow line higher than 3" below bottom of overflow fitting. DO NOT
“TIE”
THIS TUBE INTO THE DRAIN LINE OF THE CONTROL VALVE AS IT WILL RESULT IN
OVERFILLING THE BRINE TANK AND FLOODING. The overflow line must be a direct,
separate line from the brine tank overflow elbow to a drain or sump pit.
STEP 10:
Turn on water supply.
MAKE SURE THE BYPASS VALVE IS IN THE “BYPASS”
POSITION
(Figure3, Page 4) NOTE: the INLET and OUTLET knobs turn
clockwise
to close
the port to the softener and
counter-clockwise
to open the port to the softener. Open the main
supply valve or turn on power to the pump on private well systems. Check for leaks and
correct as needed.
STEP 11:
Program control valve.
Plug the transformer of the control valve into an uninterrupted
electrical outlet (not wired to a switch) and use the buttons on the front of the control valve to
adjust the initial settings:
A) SET THE TIME OF DAY
1.
Press the “SET CLOCK” button
a. The upper left of the display will show
“SET TIME”
b. The hour will flash
2. Press the UP or DOWN buttons (triangle pointing up or down) until the correct
combination of hour and
“AM” or “P M” (NOTE: letter spacing as shown on the
display) is reached to match the current time.
3.
Press the “NEXT” button
a.
The upper left of the display will show “SET TIME”
b. The minutes will flash
SET CLOCK
Button
NEXT
Button
Display Panel
REGEN
Button
FIGURE 8: Control Valve Front
Panel
UP
Button
DOWN
Button
Installation Instructions (cont.)