background image

 

 

Location Considerations 

 

The  proper  location  to  install  the  water  softener  system  will  ensure  optimum  performance  and 

satisfactory water quality.  The following factors should be considered in selecting the location of the equipment. 

1.  The water softener should be installed after the pressure tank on a private well system or after the 

water meter on municipal water. Operating pressure of the softener must be limited to within 30 

– 

100 psi range. 

 

2.  The water softener should be installed as close as possible 

(preferably within 15’) to an adequate 

floor or laundry drain capable of handling the backwash cycle volume and flow rate (refer to unit 
specifications). 

 

3.  All water conditioning equipment should be installed prior to the water heater.  Water temperatures 

exceeding 100°F can damage the internal components of the control valve and filter tank.  Install 
with at least 10’ of pipe before the water heater to prevent thermal damage to the equipment.  An 
expansion tank may need to be installed in the line to the water heater in order to allow for thermal 
expansion and comply with local plumbing codes. 

 

4.  The water softener should not be subject to freezing temperatures. 

 

5.  Ensure that any cartridge or in-line type filter installed prior to the water softener does not restrict 

the water flow and pressure available for backwash and interfere with normal operation.  
 

6.  Appliances requiring extended periods of continuous or high flow water use (i.e. geothermal heat 

pumps, swimming pools, lawn irrigation, outside hose bibs, etc.) should bypass the water softener. 
(see installation diagram Fig. 1).   
 
 
 
 

 

 

 

 

 

 

FIGURE 1:  Typical Installation 

Water Heater 

Inlet from 

water 

supply 

Treated 
Cold Water 

Iron Free Water 

Treated    
Hot Water 

Untreated Water 

Water Softener 

Iron Filter  

(if required) 

Pressure Tank 

(well system only) 

10’ Minimum Distance 

Grounding Straps 

FSN 

Pre-installation Instructions (cont.) 

Содержание FSN10

Страница 1: ...C 12630 US Highway 33 N Churubusco IN 46723 Phone 260 693 1972 Fax 260 693 0602 FSN Series Instruction Manual 180122 docx FSN Series Nitrate Removal Water Softening System Installation Instructions and Owner s Manual ...

Страница 2: ... FSN Time Clock Timer Setting Page 7 FSN Adjust Time of Regeneration Page 9 Unit Model Specifications Page 10 Component Parts Breakdown List Page 12 FSN Control Valve Breakdown Page 13 FSN Control Valve Parts List Page 14 Troubleshooting Page 15 Ten Year Limited Warranty Page 17 Table of Contents ...

Страница 3: ...r pH is reported on a scale from 0 to 14 Neutral water has a pH of 7 0 lower values indicate acidic water If your pH is below 6 8 you may consider installing an acid neutralizer before the water softener to elevate the pH Iron A naturally occurring metallic element Iron levels in excess of 0 3 milligrams liter mg l combine with oxygen causing orange or red rust stains on plumbing fixtures Iron exi...

Страница 4: ...d filter tank Install with at least 10 of pipe before the water heater to prevent thermal damage to the equipment An expansion tank may need to be installed in the line to the water heater in order to allow for thermal expansion and comply with local plumbing codes 4 The water softener should not be subject to freezing temperatures 5 Ensure that any cartridge or in line type filter installed prior...

Страница 5: ...g to inlet and outlet of bypass valve DO NOT PLUMB INLET AND OUTLET BACKWARDS Piping should be supported Do not apply heat to any fitting attached to the bypass or control valve STEP 6 Use the provided polyethylene tubing NO VINYL TUBING to run drain line from control valve discharge fitting to floor drain or sump pit capable of handling the backwash rate of the softener refer to specifications an...

Страница 6: ...HIS TIME STEP 8 Install overflow tubing from overflow elbow on brine tank to floor drain Tubing must be lower than overflow elbow at all times DO NOT CONNECT DRAIN LINE FROM SOFTENER CONTROL VALVE TO BRINE TANK OVERFLOW DO NOT CONECT BRINE TANK DRAIN LINE TO THE SOFTENER DRAIN LINE STEP 9 Place bypass valve in the Bypass position refer to Figures 4 below Open main supply valve or turn on power to ...

Страница 7: ...enough water to the brine tank to a level approximately 1 above the salt grid STEP 13 Plug the softener back into the electrical outlet Slowly rotate the Manual Regeneration knob clockwise until just one click is heard This is the Brine Draw position Verify that the water level in the brine tank is dropping Allow water level to drop below the salt grid before continuing If the water level does not...

Страница 8: ...ne how many TIMES in a 12 day cycle the FSN should regenerate If the nitrate level falls between two numbers in the table use the next highest number Example FSN10 4 people in family Nitrates 35 ppm Result Set softener to regenerate 2 TIMES in 12 day cycle once every 6 days 2 Rotate the skipper wheel until the number 1 is at the red pointer Each number represents a day The number by the red pointe...

Страница 9: ...ore precisely People Nitrates ppm or mg l 10 20 30 40 50 60 70 80 90 100 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 1 2 2 4 1 1 1 1 1 1 2 2 2 2 5 1 1 1 1 2 2 2 2 2 3 6 1 1 1 1 2 2 2 2 3 3 7 1 1 1 2 2 2 3 3 3 3 8 1 1 1 2 2 2 3 3 3 4 9 1 1 2 2 2 3 3 3 4 4 10 1 1 2 2 3 3 3 4 4 6 Numbers in this table represent an approximation of the number of times in 12 days to regenerate based on ...

Страница 10: ...4 hour gear 4 Locate the regeneration time pointer on the inside of the 24 hour dial in the cut out 5 Turn the time plate so the desired regeneration time aligns next to the raised arrow 6 Push the red button in and rotate the 24 hour dial Tighten each of the three screws 7 Push the red button and locate the pointer one more time to ensure the desired regeneration time is correct 8 Reset the time ...

Страница 11: ... gpm Backwash Rapid Rinse 1 5 3 5 Brine Draw and Slow Rinse 0 46 0 92 Injector 1 white 2 blue FACTORY REGENERATION SETTINGS Backwash minutes 4 4 Brine Rinse minutes 46 60 Rapid Rinse minutes 4 4 Brine Fill minutes 6 12 Brine Fill lbs of Salt 9 18 Total Water Used gallons 43 93 DIMENSIONS in Mineral Tank diameter x height 9 x 48 12 x 48 Brine Tank diameter x height 14 x 34 18 x 33 Overall depth x w...

Страница 12: ...11 This page intentionally left blank ...

Страница 13: ... W BP FSI682 Vlv Assy W BP B Mineral Tank MTP0948GR MTP1248GR C Distributor D100S 48 D100S 48 D Resin Qty 1 A520E Qty 2 A520E E 1 4 X 1 8 Gravel Qty 1 QC20 Qty 1 QC20 F Brine Tank Assy BT1434ASSY BTSQ1833ASSY G Overflow Fitting BT OVERFLO BT OVERFLO H Safety Brine Valve SBV14ASSY SBV14ASSY I Salt Platform BTSG14 BTSG18SQ J Bypass2 stainless steel 60040SS2 60040SS2 Top Screen not shown 18280 02 182...

Страница 14: ...13 FSN Control Valve Breakdown ...

Страница 15: ...bly 3200 12 Day STF 120 60 20 13030 Distributor Retainer J 60011 050ASSY Brine Valve 1650 Short Stem 0 5 BLFC with J Tube Not Shown 40027 J tube for 2510 valve Old Style 1 14105 Bypass Valve Seal Single Lever 22 13911 Main Drive Gear 2 13305 Coupling O Ring 019 23 18743 1 Timer Motor 120v 60Hz 2510 5600 Valve 3 19228 01 Coupling Adapter S ASSY 24 15320 Micro Switch Homing 4 10692 Injector cover sc...

Страница 16: ... application requirements and resize water softener as required B Foreign material buildup in plumbing system or water softener B Clean or replace plumbing as necessary additional treatment equipment may be required 5 Loss of resin through drain line A Air in water system A1 Check for low water table conditions in well A2 Check for positive seal on brine line connections B Drain line flow control ...

Страница 17: ...then rinse cycle 9 Water leaks to drain continuously A Foreign material in control valve A Remove and inspect piston and seal kit Replace as necessary B Drive motor stopped during regeneration cycle B Check for obstruction in piston and seals Replace drive motor Inspect condition of power head gears C Control valve continuously cycling C See Problem 10 D Internal valve seal leak D Replace seals an...

Страница 18: ...ld a defect or malfunction occur contact the dealer that you purchased the product from If you are unable to contact the dealer contact First Sales LLC 260 693 1972 We will require a full description of the problem model number date of purchase and selling dealer s business name and address We assume no warranty liability in connection with this water conditioner other than specified herein This w...