11
DESCRIPTION
UNIT MODEL NUMBER
FEST45
FEST60
MEDIA VOLUME, ft
3
1.5
2.0
HARDNESS CAPACITY, grains
Factory Salt @ 9 lb/ft
3
(146 g/L)
24,000
29,000
TANNIN CAPACITY, ppm gallons
Factory Salt @ 9 lb/ft
3
(146 g/L)
1,000
1,000
SERVICE FLOW RATES, gpm
Cont. (3 gpm/ ft
3
cation resin)
3
4
Service (5 gpm/ ft
3
resin)
8
10
Peak (Max. 20 psi drop)
14
16
PRESSURE LOSS, psi
@ Continuous Flow Rate
2
3
@ Service Flow Rate
8
9
@ Peak Flow Rate
19
19
REGENERATION FLOW RATES, gpm
Backwash
2.4
3.0
Brine Draw / Slow Rinse
0.38 / .45
0.56 / 0.84
Rapid Rinse
2.4
3.0
FACTORY REGENERATION SETTINGS
Preliminary Rinse (minutes)
--NA--
--NA--
Backwash (minutes)
6
8
Brine & Rinse (minutes)
60
60
Rapid Rinse (minutes)
6
6
Brine Fill (# of salt)
12
18
Total Water Used (gallons)
58
96
DIMENSIONS, inches
Mineral Tank (diameter x height)
10 x 54
12 x 48
Brine Tank (diameter x height)
14 x 34
18 x 33
Overall (depth x width x height)
14 x 25 x 63
18 x 31 x 57
GENERAL REQUIREMENTS:
Iron <= 0.5 ppm
Hardness <= 10 gpg
110v/60hz
4.17 amps
Specifications
Содержание FEST Series
Страница 14: ...13 FEST Control Valve Breakdown ...