12
Fault
Probable
Cause
Solution
Water changes color or be-
comes cloudy.
Rower is in direct
sunlight or has not
had water treatment.
Change rower location to reduce direct
exposure to sunlight. Add water treat-
ment or change tank water as directed
in the water treatment section of this
manual.
Knocking noise from inside
the control arm while train-
ing, especially when chang-
ing directions.
Chain requires tight-
ening or adjustment.
Open inspection plate located on front
of control arm and check tension using a
screwdriver or other tool. Use the chain
tensioning bolts located at the rear of
the control arm to tighten or adjust as
needed. The chain should have approx
3mm of slack when properly adjusted.
See P.10 for details.
Pedals slip during hard
training.
PK tank belt requires
tightening.
Remove large inspection plate next to
the tank, insert a long tool to push the
rear end cap out from the inside, expos-
ing the tank belt tensioning bolt. Loosen
tank bolts slightly. Remove upper rub-
ber belt cover to expose the PK belt.
Tighten the tank tensioning bolt until the
belt is too tight to be twisted from side to
side more than 45 degrees by hand.
See P.14 for details
Pedal is loose (either left or
right) and cannot be retight-
ened.
Aluminum crank arm
threads are stripped.
Contact service center for replacement.
Then check weekly as recommended.
Computer screen illumi-
nates, but does not register
when rowing.
Loose or failed con-
nection/Sensor gap
too wide (see erratic
computer display).
Check that the computer lead is con-
nected properly. If connected properly
check sensor gap. Contact your local
service center if this fails to address the
problem.
The E720 computer does
not illuminate after battery
installation.
Batteries installed in-
correctly or need re-
placing.
Reinstall batteries in correct position and
try again. If the LCD screen fails to illu-
minate, try rotating the batteries slightly
in the computer. If this fails, contact
your local service center.
The E720 computer display
is erratic/slow while display-
ing RPM and WATTS
Gap between sensor
and magnetic ring is
too wide.
Remove inspection plate and check sen-
sor gap and that magnetic ring is not
wobbly.
Troubleshooting guide: