background image

 

FLUID UPPER BODY ERGO (UB-E620) 

INTERNATIONAL WARRANTY – 

FULL 

COMMERCIAL USE

 

 

This product is designed and constructed for use in any Health Club / Fitness Studio application 

 
First Degree Fitness Limited warrants that the 

Fluid Upper Body Ergometer (models UB-E620)

purchased from an authorised agent and in its undamaged original packaging, is free from defects in 
materials and workmanship.  First Degree Fitness Limited or its agent will, at their discretion, repair or 
replace parts that become defective within the warranty period, subject to the specific inclusions and 
exclusions below. 

 

Metal Frame – 10 Year Limited Warranty 

First Degree Fitness will repair or replace the metal Main Frame should it fail due to any defect in ma-
terials or workmanship within 10 years of the original purchase.  Warranty does not apply to frame 
coating. 

 

Polycarbonate Tank & Seals – 3 Year Limited Warranty 

First Degree Fitness will repair or replace the polycarbonate tank or seals should they fail due to any 
defect in materials or workmanship within 3 years of the original purchase. 

 

Mechanical Components (of a non-wearing nature) – 2 Year Limited Warranty 

First Degree Fitness will repair or replace any mechanical component should it fail due to any defect 
in materials or workmanship within 2 years of the original purchase. 

 

All Other Components (of a wearing nature) – 1 Year Limited Warranty 

First Degree Fitness will repair or replace any component should it fail due to any defect in materials 
or workmanship within 1 year of the original purchase. 

 

Specific Inclusions 

Pedals & toe straps 
Hand grip assemblies 
Seat 
All rubber components  
Computer & speed sensor (excluding replaceable batteries) 
All drive belts & chains 
Crank arms 
All pulleys, rollers & bearings 

 

 

General Exclusions 

Damage to the finish of any part of the machine 
Damage due to neglect, abuse, incorrect assembly or use of the machine 
Any charges for freight or customs clearance associated with the return or dispatch of parts 
Any damage to or loss of goods during transport of any kind 
Any labour cost associated with a warranty claim 

 

General Conditions 



The serial number of the machine must be correctly registered with First Degree Fitness Limited 
or one of its appointed distributors

 



First Degree Fitness Limited reserve the right to examine any part where replacement is claimed 
under warranty

 



Warranty commences at time of sale but no later than six (6) months from date of original ship-

ment

 



Warranty period applies only to the original purchaser from the date of purchase and is not trans-
ferable

 



The product must be returned to your place of purchase in original packaging with transportation, 
insurance and associated charges paid for by you and risk of loss or damage assumed by you

 



First Degree Fitness makes no other warranties except as stated here and expressly disclaims all 
warranties not stated in this warranty.  Neither First Degree Fitness nor its associates shall be re-
sponsible for incidental or consequential damages

 



Manufacturer's warranty automatically commences upon sale of the product to end user or upon 
the expiration of one (1) year from month of manufacture, whichever occurs first

 

Содержание E620 Seated UBE

Страница 1: ...Owners Manual ...

Страница 2: ...20 assembly instructions 3 Tank filling and water treatment 4 Long term water treatment and basic operation 5 The E620 Ergometer with USB Function 6 Maintenance Troubleshooting 7 Tank belt drive Chain adjustment 8 Parts list and Warranty ...

Страница 3: ... follow all safety instructions when raising lowering the E620 control arm Warning 4 Keep fingers clear of pivot points during both assembly and use 3 Do not remove hands while crank is in motion The crank will continue to rotate and could cause injury Note The control arm is gas assisted Use both hands when raising lowering the control arm for safety ...

Страница 4: ...E620 Seat M6x20mm seat bolt M6x20mm seat bolt washer M8x15mm bracket bolt M8 spring washer Funnel W hose 6mm Allen Key 4mm Allen Key M10x25mm bolt M10 Nylock M10 Washer E620 Seat E620 Mainframe Chlorine Tablets x 4 ...

Страница 5: ...Assembling the E620 Step 1 Remove Seat frame and seat from box Attach seat using 4x M6x20mm bolts and 4x M6 washers Chrome snap faces forward ...

Страница 6: ...ng this stage of assembly The yellow tension knob is pre tightened from the fac tory in the optimal position for as sembly in relation to the control arm Do not loosen the yellow tension knob until the telescoping tube has been safely secured to the underside of the control arm as pictured left CAUTION WARNING Keep fingers clear of pivot points at all times ...

Страница 7: ...Step 3 Attach the seat frame to the mainframe using 2x M10x25mm bolts 2x M10 washers and 2x M10 nylock nuts Tighten securely E620 Assembly ...

Страница 8: ...ty is known to be poor FDF recommends the use of distilled water Draining the Fluid tank When outdoors simply open the yellow fill plug and lie the E620 on its side to facilitate drainage Indoors a container capable of holding 8 liters of water will be required Impeller blades are sharp Do not put fingers into the tank Use the end of the hose to move the impeller should the need arise Warning Wate...

Страница 9: ...e sistance handle for the correct resistance lev el to be achieved Long term water treatment Do not use any water treatment other than the tablets supplied with this machine For replacement tablets contact your local First Degree Fit ness distributor Water treatment schedules for the E620 will vary according to the fluid tanks exposure to sunlight but expect 12 months near a bright sunlit window a...

Страница 10: ...is includ ed with your E620 Quick start provides instant workout information Just start training to activate You can choose to change UNITS displayed UNITS displays RPM HR MPH KPH Level Adjusta ble from 1 20 Set Changes Time Distance parameters Program Clears cur rent exercise program Reset Clears data ...

Страница 11: ...rom the FDF Website 2 Download and Install the Sample USB Applications from the FDF Website www firstdegreefitness com Download and Install NetAthlon 2 XF for Rowers from http www webracing org downloads htm The USB Connector is located on a flying lead at the rear of the IPM along with the Sensor and Heart Rate Monitor Connectors Connect to a Laptop or PC using a standard USB cable you may need t...

Страница 12: ... manual Chain drive Check every 100 hours for correct tension Remove the Control arm front end cap and check ten sion using a screwdriver or other tool Tighten as re quired using chain tensioning bolts located at the end of the control arm Do not un der any circumstances use fingers to check chain ten sion See tightening adjusting chain section of this manual E620 pedals Tighten weekly using 15mm ...

Страница 13: ...t or right and can not be retightened Aluminum crank arm threads are stripped Contact service center for replacement Then check weekly as recommended Computer screen illu minates but does not register when rowing Loose or failed connection Sensor gap too wide see erratic com puter display Check that the computer lead is con nected properly If connected properly check sensor gap Contact your local ...

Страница 14: ...bolts are loosened tighten the chain tensioning bolts in equal small increments max 1 4 turn until the correct tension is achieved Retighten bolts If the chain requires alignment use the chain tensioning bolts individually to correct alignment as shown below Crank arm bolts Axle Tightening right chain tensioning bolt only Tightening left chain tensioning bolt only Tightening left right chain tensi...

Страница 15: ...age ceases Adjusting the E620 Drive belt Note If the belt is extremely loose the tank bolts will have to be loosened slightly before adjusting to allow maximum adjustment This will require a 10mm Allen key and 19mm wrench not supplied Do not over tighten the tank bolts once adjustment is complete Tank tensioning bolt Inspection plate cover For detailed instructions on complete belt replacement ple...

Страница 16: ...E620 Exploded Diagram Upper control arm Computer stalk mount assembly Telescoping tube gas assisted shock assembly Main frame assembly Tank assembly Seat assembly 12300 ...

Страница 17: ...d Cap 38 10114 8 Plastic Bushing 20x16x13x10 20149 1 Handle Shaft Right 10116 2 Bolt M10x60 20150 1 Bolt M10x15 10117 1 Computer Wiring 1200mm 20170 2 Chain Protection Decal 10136 1 Flywheel Shaft 20183 1 Adjuster Cover 10145 1 Bearing Spacer 30x25 1x20 5mm 20184 2 Square Adjuster Nut 10157 1 Sensor Round 20185 2 Bolt M6x100 10162 2 Grub Screw M8x10 20190 2 Aluminum Block Bearing Housing 10170 4 W...

Страница 18: ... workmanship within 1 year of the original purchase Specific Inclusions Pedals toe straps Hand grip assemblies Seat All rubber components Computer speed sensor excluding replaceable batteries All drive belts chains Crank arms All pulleys rollers bearings General Exclusions Damage to the finish of any part of the machine Damage due to neglect abuse incorrect assembly or use of the machine Any charg...

Отзывы: