CO ALARM SPECIFICATIONS 

 

Gas Detection at Typical Temperature and 
Humidity Ranges: 

 

The CO Alarm is not 

formulated to detect CO levels below 30 ppm 
typically. UL tested for false alarm resistance to 
Methane (500 ppm), Butane (300 ppm), 
Heptane (500 ppm), Ethyl Acetate (200 ppm), 
Isopropyl Alcohol (200 ppm) and Carbon 
Dioxide (5000 ppm). Values measure gas and 
vapor concentrations in parts per million.

 

Required Alarm Levels: 

 

Before 10% COHb 

exposure at levels of 30% to 70% Relative 
Humidity (RH):

• 400 ppm CO between 4 and 15 minutes
• 150 ppm CO between 10 and 50 minutes
• 70 ppm CO between 60 and 240 minutes

The unit is designed not to alarm when exposed 
to a constant level of 30 ppm for 30 days.

 

Audible Alarm: 

 

85dB minimum at 10 feet

 

Power: 

 

Powered by 120V AC. When power 

is on, green light shines continuously. Digital 
Display: Dash lit by READY.

 

Display Accuracy: 

 

Accuracy is +100% -40% 

of actual concentration of CO at 50% RH +/-
5% RH and 73˚F +/- 4˚F (23˚+/- 2˚C).

 

Peak CO Reading: 

 

Digital Display shows the 

highest level of CO (ppm) detected since the 
Peak memory was last cleared. 

 

Malfunction: 

 

Yellow light shines continuously. 

Red light flashes. Horn chirps twice a minute. 
Digital Display will read “Err”.

 

Dimensions: 

 

5.83" x 3.32" x 1.6" (Approx.)

 

Supply Voltage: 

 

120V AC 60Hz

.085A Standby .087A Alarm

 

During Alarm: 

 

CO Alarm horn sounds while the 

red light flashes rapidly. Digital Display: Shows 
CO levels in ppm.

 

Warranty: 

 

5-year limited warranty.

 

Standards: 

 

Underwriters Laboratories Inc. 

Single and Multiple Station carbon monoxide 
alarms UL2034.

According to Underwriters Laboratories Inc. 
UL2034, Section 1-1.2: “Carbon monoxide 
alarms covered by these requirements are 
intended to respond to the presence of carbon 
monoxide from sources such as, but not limited 
to, exhaust from internal-combustion engines, 
abnormal operation of fuel-fired appliances, 
and fireplaces. CO alarms are intended to alarm 
at carbon monoxide levels below those that 
could cause a loss of ability to react to the 
dangers of Carbon Monoxide exposure.” This 
CO Alarm monitors the air, and is designed to 
alarm before CO levels become life threatening. 
This allows you precious time to leave the 
house and correct the problem. This is only 
possible if alarms are located, installed, and 
maintained as described in this manual.

 

M06_1040_001.E  Page 6  Thursday, July 13, 2000  7:57 AM

Содержание FCD2DDN

Страница 1: ...anual 120V Plug In Carbon Monoxide Alarm With Digital Display and Silence Feature M06 1040 000 Rev B 6 99 120V AC 60 Hz 085A Standby 087A Alarm With Peak CO Level Display M06_1040_001 E Page 1 Thursda...

Страница 2: ...he Silence Feature 11 CHAPTER 4 TESTING AND MAINTENANCE 12 CHAPTER 5 WHAT YOU NEED TO KNOW ABOUT CO 13 What is CO 13 Symptoms of CO Poisoning 13 Potential Sources Of CO In The Home 14 How Can I Protec...

Страница 3: ...any alarm Failure to do so can result in injury or death WARNING This CO Alarm can not operate without continuous electricity It does not operate during a power failure WARNING NEVER ignore your Carb...

Страница 4: ...specified time measured in minutes When the unit is in alarm mode the Digital Display will show the levels of CO measured in parts per million present This Carbon Monoxide Alarm features a permanentl...

Страница 5: ...ly display levels of carbon monoxide 30 ppm or higher 70 or higher The unit is calibrated to sound an alarm before 240 minutes have passed when exposed to this level 150 or higher The unit is calibrat...

Страница 6: ...en light ON Yellow light ON Red light FLASHES Horn chirps about twice a minute Digital Display Err During Normal Test All three lights flash briefly Horn pattern repeats twice 4 beeps pause 4 beeps pa...

Страница 7: ...el will be saved even after a power interruption until you clear it The CO alarm will automatically switch back to READY immediately after you check or clear the peak CO level Examples of when to use...

Страница 8: ...function Yellow light shines continuously Red light flashes Horn chirps twice a minute Digital Display will read Err Dimensions 5 83 x 3 32 x 1 6 Approx Supply Voltage 120V AC 60Hz 085A Standby 087A A...

Страница 9: ...ng heat source In a Multi level Home Install at least one CO Alarm near or within each separate sleeping area For added protection install at least one CO Alarm on each level of the home If you have a...

Страница 10: ...ndows Blowing air may prevent CO from reaching the sensors In direct sunlight In outlets covered by curtains or other obstruction WARNING This CO Alarm is designed for use inside a single family home...

Страница 11: ...pause 4 beeps The sequence should last 5 6 seconds During testing the green yellow and red lights flash This is normal 888 will appear on the Digital Display 4 While testing the unit have a family me...

Страница 12: ...nvestigate for sources of CO from fuel burning equipment and appliances and inspect for proper operation of this equipment If problems are identified during this inspection have the equipment serviced...

Страница 13: ...etc Press and hold the Test Silence button until the horn is silent The initial Silence cycle will last approximately 4 minutes NOTE After the initial 4 minute Silence cycle the CO Alarm re evaluates...

Страница 14: ...horn starts sounding REGULAR MAINTENANCE To keep the CO Alarm in good working order Test it every week using the Test Silence button Vacuum the CO Alarm cover at least twice a year using the soft bru...

Страница 15: ...bbing headache drowsiness confusion fast heart rate Extreme Exposure Convulsions unconsciousness heart and lung failure Exposure to Carbon Monoxide can cause brain damage death CAUTION Some individual...

Страница 16: ...outdoor conditions such as Wind direction and or velocity including high gusty winds Heavy air in the vent pipes cold humid air with extended peri ods between cycles Negative pressure differential re...

Страница 17: ...ing appliances Check appli ances for excessive rust and scaling Also check the flame on the burner and pilot lights The flame should be blue A yellow flame means fuel is not being burned completely an...

Страница 18: ...e healthy adults after 35 minutes but can cause death after 2 hours IMPORTANT This CO Alarm measures exposure to CO over time It alarms if CO levels are extremely high in a short period of time or if...

Страница 19: ...CO Alarm goes back into alarm 4 minutes after you press the Test Silence button CO levels still indicate a potentially dangerous situation Refer to Chapter 3 If Your CO Alarm Alarms for details on ho...

Страница 20: ...olic beverages This is especially true if the door is closed or only partly open Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or closed doors Noise from t...

Страница 21: ...r damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current or use contrary to the operating instructions disassembly repair or alteration by...

Отзывы: