PANIC KEYS

(FOR MANUALLY ACTIVATING SILENT AND/OR AUDIBLE ALARMS)

Using

Panic Keys

Your system may have been programmed to use special keys to manually activate panic
functions. The functions that might be programmed are listed below. See your installer for the
function(s) that may have been programmed for your system.

Your installer
should note the
functions that
are active in
your system.

  Keys

 Zone

Active Panic Function

A* or 1 and 

 95

B* or 

 and #

 99

C* or 3 and #

 96

 

N

ot  present on certain Fixed-word keypads, which use paired keys to activate panic alarms (e.g., 1 and 

, etc.).

If your keypad has lettered keys for panic functions, press the designated key and hold down
for at least 2 seconds to activate the panic function. To use a panic function initiated by paired
keys, simply press both keys of the assigned pair at the same time.

Types of Panic

Alarms

If your system is

   connected to an
   alarm monitoring  
   company.

A silent emergency sends an alarm signal
to the alarm monitoring company,* but there
will be no audible alarms or visual displays.
An audible emergency sends an
emergency message to the alarm monitoring
company* and sounds a loud, steady alarm
at your keypad  and at any external sounders
that may be connected (ALARM plus a zone
number is also displayed).

A personal emergency alarm sends an
emergency message to the alarm monitoring
company* and sounds at keypads, but not at
external sounders ( A L A R M  plus a zone
number is also displayed).

A fire alarm sends a fire alarm message to
the alarm monitoring company* and uniquely
activates the keypad and any external
sounders (FIRE  plus a zone number is also
displayed).

Содержание FA1620

Страница 1: ...N7527 1V2 Rev B 4 99 USER S MANUAL F F F FA A A A1 1 1 16 6 6 62 2 2 2C C C C S S S Se e e ec c c cu u u ur r r ri i i it t t ty y y y S S S Sy y y ys s s st t t te e e em m m m Previous Menu...

Страница 2: ...2...

Страница 3: ...2 Partition Away Arming 17 ARMING ALL PROTECTION MAXIMUM 19 DISARMING AND SILENCING ALARMS 20 Memory of Alarm 20 BYPASSING PROTECTION ZONES 21 Quick Bypass 22 Displaying Bypassed Zones 22 CHIME MODE...

Страница 4: ...he phone lines to a central alarm monitoring station A Partitioned System Simply stated a partitioned system is a single physical alarm system that provides two independent areas of protection intende...

Страница 5: ...ay Perimeter Armed Interior Armed AWAY Yes Yes Yes Yes STAY Yes Yes Yes No INSTANT Yes No Yes No MAXIMUM Yes No Yes Yes Security Codes At the time of installation you were assigned a personal four dig...

Страница 6: ...u to access the system via a Touch tone phone either on premises or by call in when away The phone access feature will enable you to do the following Receive synthesized voice messages over the teleph...

Страница 7: ...restart the exit delay by pressing the key Ask your installer if this feature is active for your system Entry Delays give you time to disarm the system when you re enter through the designated entranc...

Страница 8: ...isplayed on the keypad along with a zone number indicating the faulted zone To stop the alarm the system must be disarmed your code plus OFF to clear the display enter your code plus OFF a second time...

Страница 9: ...meric LCD which can display system messages in friendly English These keypads can also be programmed with custom zone descriptors The screen displays depicted throughout this manual are examples of di...

Страница 10: ...TANT CODE CHIME READY PANIC 1 2 3 4 5 6 7 8 9 0 ARMED ALARM CHECK FIRE AWAY STAY INSTANT BYPASS NO AC CHIME BAT NOT READY ARMED READY Professional OFF AWAY STAY MAXIMUM TEST BYPASS INSTANT CODE CHIME...

Страница 11: ...TYLE B KEYPAD DISPLAY AWAY STAY INSTANT BYPASS ALARM CHECK FIRE NOT READY NO AC CHIME BAT ALARM FIRE AWAY BYPASS STAY CHECK INSTANT NO AC NOT READY CHIME BAT CHIME Appears when the CHIME feature is ON...

Страница 12: ...system 8 INSTANT KEY Arms in manner similar to STAY mode but without the entry delay feature Entering via the entry exit door will cause an instant alarm 9 CODE KEY Used to assign additional user code...

Страница 13: ...he entry is aborted and must be repeated from its beginning ARMED READY Professional OFF AWAY STAY MAXIMUM TEST BYPASS INSTANT CODE CHIME READY 1 A B C D 2 3 4 5 6 7 8 9 0 First Alert 1 15 14 2 5 16 8...

Страница 14: ...DISARMED PRESS Note Keypads light a green READY indicator when system TOSHOW FAULTS is ready If not lit the system is not ready to be armed READY PRESS THE READY KEY 1 Do not enter the security code b...

Страница 15: ...e all protected perimeter windows and doors before arming see CHECKING FOR OPEN ZONES section The green READY indicator on the keypad should be lit if the system is ready to be armed STAY 1 3 ENTER SE...

Страница 16: ...arming see CHECKING FOR OPEN ZONES section The green READY indicator on the keypad should be lit if the system is ready to be armed INSTANT 1 7 ENTER SECURITY CODE THEN PRESS INSTANT Security Code Exa...

Страница 17: ...ion The green READY indicator on the keypad should be lit if the system is ready to be armed AWAY 1 2 ENTER SECURITY CODE THEN PRESS AWAY Security Code Example 7 2 9 6 then press the AWAY key 2 ARMED...

Страница 18: ...pires The first press of AWAY arms the local partition the second press of AWAY arms the other remote partition The Armed Away display should appear and remain displayed with exit warning beeps if pro...

Страница 19: ...larm will be sounded as soon as someone re enters Close all protected perimeter windows and doors before arming see CHECKING FOR OPEN ZONES section The green READY indicator on the keypad should be li...

Страница 20: ...premises LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location To disarm the system and silence burglary alarms OFF 1 1 ENTER SECURITY CODE THEN PRESS OFF Security Code Example 7 2 9 6...

Страница 21: ...ypass zones the system must be disarmed first BYPASS 1 6 ENTER SECURITY CODE THEN PRESS BYPASS Security Code Example 7 2 9 6 then press the BYPASS key 2 ENTER ZONE NUMBERS Zone Numbers Enter the zone...

Страница 22: ...be displayed along with the word BYPASS Wait for these zones to be displayed before arming Arming the system before zones are displayed eliminates all bypasses 3 DISARMED BYPASS READY TO ARM ARM AS U...

Страница 23: ...w is opened Pressing the READY key will display the open protection points Note that the Chime mode can be activated only when the system is disarmed To turn Chime Mode on CHIME 1 9 ENTER SECURITY COD...

Страница 24: ...function To use a panic function initiated by paired keys simply press both keys of the assigned pair at the same time Types of Panic Alarms If your system is connected to an alarm monitoring company...

Страница 25: ...er for a full explanation of this feature To activate devices ENTER SECURITY CODE THEN PRESS 7 DEVICE NUMBER 7 Security Code Device Number Example 7 2 9 6 then press then press 7 then enter the number...

Страница 26: ...be a 3 digit User or a zone number depending on the type of event that has occurred The 3 digit Event Codes EEE that can be displayed are 911 Alarm NNN that follows this code will be the zone number t...

Страница 27: ...ysitter Code This code can be used to arm the system in assigned partitions but cannot disarm the system unless the system was armed with this code This code is typically assigned to someone such as a...

Страница 28: ...4 digit master code then press CODE key 2 Enter 2 digit user number User Number Enter the 2 digit User Number 03 16 for the user you are adding or changing 3 Enter 4 digit user s code User s Code Ent...

Страница 29: ...YSTEM Disarm the system and close all protected windows doors etc The Ready message should be displayed and the green READY indicator lit TEST 2 5 ENTER THE SECURITY CODE THEN PRESS TEST Security Code...

Страница 30: ...nufacturer s instructions The identification of each detector should appear on the display when each is activated If a problem is experienced with any protection point no confirming sounds no display...

Страница 31: ...m the detector If the problem has been corrected the zone and Zone No descriptor s and CHECK should disappear If not key an OFF sequence security code plus OFF to clear the display A CHECK condition c...

Страница 32: ...nsmitters 6 MODEM COMM Indicates that the control is on line with the central or CC station s remote computer The control will not operate while on line Wait a few minutes The display should disappear...

Страница 33: ...seconds The alarm will sound 2 Evacuate all occupants from the premises 3 If flames and or smoke are present leave the premises and notify your local Fire Department immediately 4 If no flames or smok...

Страница 34: ...in the National Fire Protection Association s NFPA Standard 74 noted below Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the...

Страница 35: ...nd rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room 4 Make sure that all bedroom door...

Страница 36: ...in most units and applications provide 2 4 years of service 3 volt lithium batteries provide up to 4 or more years of operation Actual battery life will depend on the environment in which the sensor...

Страница 37: ...soon as the sensor is activated opening closing of door window etc causing the low battery display to turn off If the sensor is not activated the display will automatically clear within approximately...

Страница 38: ...ones Bypassed zones are un Press BYPASS 6 protected and will not cause an alarm if violated Enter zone numbers to be bypassed use 2 digit entries Quick Bypass Enter code Do this to bypass all faulted...

Страница 39: ...rmal mode Press OFF 1 Add or Change Enter master code Do this to add or change a user code a User Press CODE 8 Enter user s 2 digit user No Enter code for that user Delete a User Enter master code Do...

Страница 40: ...every 40 sec Keypad only LOW BATTERY AT A TRANSMITTER LO BAT displayed with description of transmitter TWO SHORT BEEPS Keypad only ARM AWAY OR MAXIMUM ARMED AWAY or ARMED MAXIMUM is displayed Red ARM...

Страница 41: ...ZONE A specific area of protection PARTITION An independent group of zones that can be armed and disarmed without affecting other zones or users BYPASS To disarm a specific area of burglary protectio...

Страница 42: ...e tiquette certifie que le mat riel est conforme certaines normes de protection d exploitation et de s curit des r seaux de t l communications Le minist re n assure toutefois pas que le mat riel fonct...

Страница 43: ...s Insurance Company Policy No First Alert Professional FA162C Other _____________ Type of Alarm Burglary Fire Both Installed by Serviced by Name Name Address Address B NOTIFIES Insert B Burglary F Fir...

Страница 44: ...Attic Basement Living Room Dining Room Hall F BURGLARY DETECTING DEVICE LOCATIONS Front Door Basement Door Rear Door All Exterior Doors 1st Floor Windows All windows Interior locations All Accessible...

Страница 45: ...the receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user or installer may find th...

Страница 46: ...cal the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe necessary The telephone company may make c...

Страница 47: ...oke detectors have played a key role in reducing residential fire deaths in the United States they may not activate or provide early warning for a variety of reasons in as many as 35 of all fires acco...

Страница 48: ...reo radio air conditioner or other appliance or by passing traffic Finally alarm warning devices however loud may not warn hearing impaired people or waken deep sleepers Telephone lines needed to tran...

Страница 49: ...ind of regular service program with him is advisable Your local First Alert dealer is Name _________________________________________________________________ Address ___________________________________...

Страница 50: ...16 38 40 Instant Mode 16 38 Keypads 9 10 11 12 13 Keyswitch 26 Lo Bat 32 40 Low Battery 11 32 36 37 40 Maximum 5 7 12 19 38 40 Maximum Mode 19 38 Memory Of Alarm 6 20 26 40 Modem Comm 32 National Fir...

Страница 51: ...LER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMA...

Страница 52: ...N7527 1V2 N7527 1V2 Rev B 4 99 175 Eileen Way Syosset New York 11791 Copyright 1997 PITTWAY CORPORATION...