NYLON/STEEL FIRE ESCAPE LADDER
MODEL EL52
This nylon/steel Fire Escape Ladder is easy to use,
and provides a reliable means of escape through
a second floor window during a home fire.
M08-0041-001 07/04
FEATURES AND BENEFITS
• For use in two-story homes
• Strong nylon construction
• Fully assembled, ready to use
• Slip-resistant epoxy coated rungs
• Large hooks secure easily to windowsills
• Steel rung stabilizers on all rungs
• Ladder complies with the ASTM Standard F 2175-02.
375 lb. Ladder load rating
• Ladder is 14 feet (4.3 meters) in length.
1
• Read instructions for use immediately upon purchase.
• Close doors before opening any windows to prevent fire from being drawn into the room.
• Keep body close to ladder.
• Unless absolutely necessary, do not carry a child when using this ladder.
• Do not carry pets or miscellaneous objects when using this ladder.
• Instruct family members to use this portable escape ladder only when the primary escape path
(that is, the main exit) is blocked or unsafe to use.
• This portable escape ladder is not a toy or recreational device. Instruct children that the ladder
is to be used only in an emergency.
• For use only in windows that are structurally safe for the intended load.
• Not recommended for use with storm windows or other windows that do not open to the
recommended minimum dimensions [20 inches (51 cm) wide and 32 inches (81 cm) high].
• Do not use above a 2 story height.
• Do not attempt to deploy the ladder from windows that are obstructed by furniture, radiators,
air conditioning units, or security devices such as grilles or bars (without inside release
mechanisms).
• Do not attempt to deploy the ladder into flames.
• Check for outside obstructions such as electric lines, telephone wires, or fences.
• Do not attempt to use the ladder if the windowsill does not meet the size range specified.
The windowsill width should be between a minimum of 6 inches (15 cm) and a maximum of
10 inches (25 cm).
• Always plan and practice drills to ensure that occupants are familiar enough for proper use.
• This ladder is intended to supplement (not replace) the more important fire protection principles
of fire drills, emergency evacuation plans, smoke alarms, fire extinguishers, etc.
• This ladder should be periodically inspected for damage, loosening of any items, or significant
deterioration of the materials of construction.
• This ladder is designed for use by one person at a time.
• Store the ladder in a convenient location near the exit window; for example, under a bed, in a
closet, etc.
USER’S MANUAL
All Rights Reserved. © 2003 BRK Brands, Inc.
4BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005 • www.firstalert.com