When Transporting Generator
Transport with fuel tank EMPTY or with fuel switch in OFF position.
Do not tip generator at an angle which causes fuel to spill.
ENGINE MAINTENANCE
To prevent accidental starting, remove and ground spark plug wire before performing any service.
Change Engine Oil
Change engine oil every 100 hours. (for a new engine, change oil after 25 hours.)
If you are using your generator under extremely dirty or dusty conditions, or in extremely hot
weather change the oil more often.
CAUTION! Avoid prolonged or repeated skin contact with used motor oil. Used motor oil has been
shown to cause skin cancer in certain laboratory animals. Thoroughly wash exposed areas with
soap and water.
KEEP OUT OF REACH OF CHILDREN. DON’T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL
TO COLLECTION CENTERS.
NOTICE
We recommend using FIRMAN SAE 10W-30 API SJ oil for best performance. Other high-
quality detergent oils (API SJ or higher) are acceptable. See
Oil and Gasoline / LPG.
27
Maintenance - Storage
(
a
)
Loosen
the
cover
screws
and
remove
the maintenance
cover
.
(
b
)
Pop up the rubber plug from below yellow draining bolt.
(
c
)
Remove
yellow drain bolt
.
(
d
)
Tilt
the
generator
on
its
side
and
allow
the
oil
to drain
completely
.
(
e
)
Replace
yellow drain bolt
.
(f
)
.
DO
NOT
OVERFILL
.
Fill the engine with oil until it reaches the HIGH(H) level on the oil filler cap
Содержание WH03344
Страница 8: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS ...
Страница 9: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS ...
Страница 10: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS ...
Страница 38: ...PARTS DIAGRAM AND PART LIST WH03344 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 36 ...
Страница 39: ...193cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 37 ...
Страница 43: ...English Customer Service 1 844 FIRMAN1 41 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram ...