Firman WH03242 Скачать руководство пользователя страница 42

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

40

Parts Diagrams - Parts Lists - Wiring Diagram

NO. Part Number

Description

Qty.

75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99

100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124

125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172

NO. Part Number

Description

Qty.

330713657
336718362
330713527
336755005
336713575
333717010
330713613
330713602
336718383
333457007
330713618
330713608
330713629
330713603
336718345
336713577
333717011
336713579
336713580
330713596
336713588
336713584
330713593
330713614
330713594
330713592
336713589
336713565
329713608
333717012
330713659
330713655
330713577
336718364
336713565
330713595
333717013
336713822
333457010
330713654
336718383
330713660
330713656
336718383
336713616
330713599
330713606
336755002
336713574
336755004

Pull Chock Assembly
Screw M5×14
Bolt M6×16
Circuit Breaker Cover

Screw M3×10
Receptacle Cover, USB
Receptacle Cover
Screw M4×14
Table

Receptacle DC 12v
Switch
Parallel Ports
Bolt M5×16
Nut M5
Nut M5
Washer Ø5
Washer Ø5
Nut M4
Receptacle 5-20R Duplex
Receptacle TT-30R
Receptacle USB

Control Box
Screw M5×38
Screw M5×14
Washer Ø5
Screw M5×12
Stents, Fuel Valve
Quick Coupler
Fuel Valve
Screw M5×20
Screw M5×14
Speed Limiter
Nut M3
Micro Switch
Control Panel
Lpg Inlet Cover
Screw M4×14

Fuel Valve Knob
Screw M4×14
Lgnition Switch
Switch,economy
Receptacle Cover,DC 12V
Indicator Light
Receptacle Cover,TT-30R
Engine Switch Cover

333717013
336727009
336718315
330713564
330713565
392428300
332717002
332717007
332717003
330713574
330713651
330713650
330713582
336713561
332457008
332457007
330713588
330713583
330713585
333727001
330713587
333727002
336718302
330713563
333717014
330713589
330713584
333717015
336718330
330713623
330713622
332457009
333717016
330713620
330713624
333427008
357713571
332457010
332457011
336713540
330713636
330713635
330713637
330713638
332727005
332717004
330723533
332717006

Screw M5×14
Switch Cover
Nut M8
Supporter,right
Motor Mount
CO Module
Washer
Bushing
Stents,Fuel Valve
Rectifier
Charger
Control Module
Screw M4×14
Bolt M6×25
Ground Wire
Inverter
Base Setting Component
Plug,Wheel
Washer Ø12
Wheel, Right
Axle
Wheel, Left
Bolt M6×12
Supporter,Left
Nut
Plug 
Retaing Ring Ø12
Rubber Mat
Bolt M6×20
Pinch,Rubbre
Sheath,Battery
Battery(5.5AH)
Screw M5×14
Stents I,battery
Stents II,battery
Cushion
Sheath,Connecter Black
Battery Wire(red)
Battery Wire(black)
Clip (ø8×6)
Vapor Hose 2
Vapor Hose 1
Carbon Canister
Vapor Hose 3
Cover
Screw M4×5
Screw M5×10
Screw M5×14

1
4
2
2
1
1
1
2
2
1
1
1
1
2
1
1
1
2
1
6
1
1
1
1
1
1
2
1
1
4
1
1
1
2
2
1
5
1
1
1
2
1
1
1
1
1
1
1
1
1

6
1

12

1
4
1
1
2
1
1
1
1
5
2
1
1
1
2
2
1
1
1
4
1
8
1
2
2
2
1
1
1
3
1
1
1
1
1
1
1
1
1
1
1
1
2
1
2

Receptacle Cover,5-20R Duplex

Receptacle(Battery Charger)

D.C 10A Breaker,push Button
A.C 20A Breaker,push Button

Receptacle (Battery Charger)

Содержание WH03242

Страница 1: ...P N 332745482 Rev 01 OPERATOR S MANUAL DUAL FUEL INVERTER GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER WH03242 Rev Level 01...

Страница 2: ...e harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or...

Страница 3: ...rt This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supplyin...

Страница 4: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Страница 5: ...may be Federal or State regulations local codes or ordinances that apply to the intended use of the generator Consult a qualified electrician electrical inspector or the local agency having jurisdict...

Страница 6: ...ing through any openings If an extension cord running directly into your home is used to power indoor items the operator recognizes that this increases the risk of CO poisoning to people inside the ho...

Страница 7: ...on this page 05 FEATURES AND CONTROLS 1 Fixed 2 Fuel Cap 3 LPG Hose Quick Connect Inlet 4 Recoil Starter 5 Never Flat Wheel 6 Control Panel 7 Muffler Spark Arrester 8 Folding Handle Carrying Handle 9...

Страница 8: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS...

Страница 9: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS...

Страница 10: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS...

Страница 11: ...20 Amps current may be drawn from this duplex receptacle 5 120V 30A RV NEMA TT 30R A maximum of 26 7 Amps current may be drawn from this receptacle 6 Output Ready Indicator Light Remains ON during no...

Страница 12: ...xternal short circuit occurs the circuit protector will trip 14 Parallel Operation Outlets These outlets are used for connecting two FIRMAN inverter generators for parallel operation A FIRMAN parallel...

Страница 13: ...crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even...

Страница 14: ...able generator at least 5 ft 1 5 m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator in...

Страница 15: ...l for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil Damage due to operation w...

Страница 16: ...oil level may not be high enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is correc...

Страница 17: ...ative main jet and installation instructions can be obtained by contacting Customer Support NOTICE Operation using an alternative main jet at elevations lower than the recommended minimum altitude can...

Страница 18: ...CSA B149 1 Natural Gas and Propane Installation Code as applicable If possible the fuel supply connection should be close to the outdoor operating location This will reduce the cost of the flexible fu...

Страница 19: ...portable generator outdoors to safe operating location at least 20 feet from any occupied spaces 4 Disconnect all electrical loads from the generator Never start or stop the generator with electrical...

Страница 20: ...e plugging in any electrical devices NOTICE If engine starts but fails to run or if portable generator shuts down during operation check oil level See Low Oil Shutdown section for more information 10...

Страница 21: ...are all in place 2 Move portable generator outdoors to safe operating location at least 20 feet 6 m from any occupied spaces 3 Connect the LPG hose with regulator to both LPG cylinder and portable gen...

Страница 22: ...step 13 10 For recoil start only PULL TO PRIME Pull the starter cord 1 2 times Pull slowly until resistance if felt and then pull rapidly 7 Flip the engine switch to the RUN l position 8 Push the batt...

Страница 23: ...re situations it can be helpful to Exchanging fuel cylinders to allow the first cylinder to warm up repeating as necessary Placing the LPG cylinder at the end of the generator near the handle where en...

Страница 24: ...position 2 Start the generator with no electrical load attached 3 Allow the engine to run for several minutes to stabilize 4 Plug in and turn on the first item It is best to attach the item with the l...

Страница 25: ...e FIRMAN authorized service dealer Yellow light will blink for five seconds at the startup of generator to show CO ALERT is functioning properly TM Carbon monoxide accumulated around generator Prior t...

Страница 26: ...lly NOTICE Storage batteries give off EXPLOSIVE hydrogen gas while charging Do not allow smoking open flames sparks or spark producing equipment in the area while charging WARNING Battery electrolyte...

Страница 27: ...et the generator run at no load for one minute to stabilize internal temperatures of the engine and generator 25 OPERATION 3 Turn the main fuel selector switch in this position to LPG position 1 30 o...

Страница 28: ...ral minutes to stabilize 3 Plug in and turn on the first item It is best to attach the item with the largest load first 4 Allow the engine to stabilize 5 Plug in and turn on the next item 6 Allow the...

Страница 29: ...lter New spark plug and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable experienced owner or by authorized...

Страница 30: ...ith used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSER...

Страница 31: ...s oil Spark Plug Maintenance Changing the spark plug will help your engine start easier and run at peak performance a Remove the maintenance cover b Remove the spark plug boot c Remove spark plug usin...

Страница 32: ...with a spark arrester as defined in Section 4442 maintained in effective working order Other states or federal jurisdictions may have similar laws reference Federal Regulation 36 CFR Part 261 52 30 M...

Страница 33: ...e spark arrester in the muffler and attach spark arrester cover with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Make...

Страница 34: ...ry Disconnect the red cable from red terminal on the battery Rubber Sheath Battery Positive Terminal Negative Terminal 6 Install the new battery with following specification 5 Remove the battery and r...

Страница 35: ...aintain a proper charge if the portable generator is used on a regular basis about once every two weeks If it is used less frequently we can use the supplied charger plugged into the generator 12V DC...

Страница 36: ...wn 3 There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained tur...

Страница 37: ...line 5 Drain fuel tank and carburetor fill with fresh gasoline 6 Connect wire to spark plug 7 Replace spark plug 8 Drain gas tank and carburetor fill with fresh gasoline 9 Wait 5 minutes and re crank...

Страница 38: ...thane Type Yes FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section Recoil Electric English Customer Service 1 844 FIRMAN1 AC Grounding System Neutral Floating 36 Troubleshooting Specificati...

Страница 39: ...PARTS DIAGRAM AND PART LIST WH03242 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 37...

Страница 40: ...193cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 38...

Страница 41: ...Rear Cover Cage Nut M5 Bolt M6 16 Screw M5 14 Protector Rear Cover Screw M6 12 Right Cover Screw M5 14 Handle Right Spring Leaf Rubber Seal Sleeve Screw St4 2 9 5 Cover Right Muffler Cover Right Side...

Страница 42: ...eed Limiter Nut M3 Micro Switch Control Panel Lpg Inlet Cover Screw M4 14 Fuel Valve Knob Screw M4 14 Lgnition Switch Switch economy Receptacle Cover DC 12V Indicator Light Receptacle Cover TT 30R Eng...

Страница 43: ...1 1 2 2 1 1 1 4 1 1 1 1 2 1 1 2 1 1 1 2 1 2 1 1 1 2 2 1 1 4 1 1 1 1 1 2 1 2 1 1 1 6 1 1 2 1 1 1 1 1 2 2 2 1 1 1 1 2 2 2 2 2 2 2 2 1 2 2 1 1 1 1 1 4 2 1 2 1 1 1 1 1 2 2 1 1 1 1 2 1 2 1 1 1 1 2 1 2 1 1...

Страница 44: ...English Customer Service 1 844 FIRMAN1 42 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Страница 45: ...ercial industrial use Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser This warranty only applies to the original...

Страница 46: ...ct Information You may contact FIRMAN at Address Firman Power Equipment Inc Attn Customer Service 8716 W Ludlow Dr Suite 6 www firmanpowerequipment com Peoria AZ 85381 We are FIRMAN POWER And we are h...

Страница 47: ...a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part o...

Страница 48: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Страница 49: ...l rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT INC 8716 W LUDLOW DR SUITE 6 PEORIA AZ 85381 1 844 347 6261 WWW FI...

Отзывы: