background image

Page 26

 SPE80 80cc Engine Parts List

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

317723500
317723501
317723502
317723503
317723504
317723505
317723506
317723507
317723508
317723509
317723510
317723511
317723512
317723513
317723514
317723515
317723516
317723517
317723518
317723519
317723520
317723521
317723522
316718300
317723524
316718301
317723526
317723527
317723528
317723529
317723530
317723531
317723532
317723533
317723534
317723535
317723536
317723537
317723538
317723539
317723540
317723541
317723542
317723543
317723544
317723545
317723546
317723547
317723548
317723549
317723550
317723551

1
2
3
4
5
6
7
8
9

10

11

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52

NO. Part Number

Description

Qty.

Bolt M6×12
Starter Assy.
Bolt M6×15
Nut
Air Shroud Comp.
Nut M12
Fan Case
Oil Seal 20×35×5
Crankcase Comp         
Ignition Assy.  
Bolt M6×20
Bearing 6204
Protector Cover Seal 2
Protector Cover Seal 1
Crank Comp               
Key
Dawl Pin
Crankcase Gasket         
Oil Level Switch       
Oil Level Switch  Plate     
Crankcase  Cover
Trigger Assy
Bolt M6×12
Stator Comp.             
Bolt M6×35
Rotor Comp.              
Rubber.end Cover 2
Rubber.end Cover 1
Bolt M6×22
End  Cover                
Spark Arrester Clamp
Spark Arrester Base
Spark Arrester
Rubber Seal        
Generator Fan                 
Piston Pin Clip                       
Piston Pin                
Conn. Rod Assy.        
Piston Ring Set
Piston                        
Camshaft Comp.               
Valve  Lifter                
Push Rod
Spark Plug
Stud Bolt M6×27

Muff. Protector Assy. Rh     
  
Nut
Muff  Comp          
Auspuffdichtung
Protector Muff. Side       

9
1
5
1
1
2
1
2
1
1

10

2
1
1
1
2
4
1
1
1
1
1
2
1
2
1
1
1
4
1
1
1
1
1
1
2
1
1
1
1
1
2
2
1
6
4
1
1
2
1
1
1

317723552
317723553
317723554
317723555
317723556
317723557
317723558
317723559
317723560
317723561
317723562
317723563
317723564
317723565
317723566
317723567
317723568
317723569
317723570
317723571
317723572
317723573
317723574
317723575
317723576
317723577
317723578
317723579
317723580
317723581
317723582
317723583
317723584
317723585
317723586
317723587
317723588
317723589
317723590
317423500
317423501
317423502

53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94

NO. Part Number

Description

Qty.

Setting Flash Board
Muff. Protector Seal
Nut
Breather Pipe
Cyl. Head Cover Assy
Cylinder Cover  Gasket          
Air Shroud,cylinder Comp.         
Bolt M6×50
Cylinder Head Comp.              
Gasket,cylinder 
Carburetor Bolt
Gskt,insulator
Insulator.carb.
Gskt,carb
Carb. Assy.        
Gskt,air Cleaner          
Pipe,air Cleaner                        
Jt.,breather Pipe             
Case,air Cleaner Comp.   
Element            
Case,air Cleaner        
Bolt M6×20
Nut,valve Adjusting         
Screw,valve Adjusting         
Arm,valve Rocker             
Shaft,screw Rocker             
Lock Clip. Valve     
Ret.,valve Spring             
Oil Seal,valve           
Spring,valve
Valve,intake    
Valve,e×haust
Oil Filler Cap Assy
Bolt M6×8
Oil Nozzle
Bolt M6×20
Bracket,ignition Assy.
Nylon Cord
Tube Clip
Air Cleaner Set
Gasket Set
Spark Arrestor Kit

1
1
6
1
1
1
1
4
1
1
2
1
1
1
1
1
1
1
1
1
1
1
2
2
2
1
2
2
1
2
1
1
1
1
1
4
1
1
1
1
1
1

Self-tapping Screw St4.8×17

Muff. Protector Assy.middle  

Содержание W01784

Страница 1: ...OPERATOR S MANUAL PORTABLE INVERTER GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER W01784 Rev Level 01 P N 317745453 Rev 06 ...

Страница 2: ...asonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful in...

Страница 3: ...il Shutdown 16 Do Not Overload Generator 16 Parallel Operation 16 Maintenance And Storage 17 Maintenance Schedule 17 Engine Maintenance 18 Change Engine Oil 18 Air Filter Maintenance 18 Spark Plug Maintenance 19 Cleaning Fuel Strainer 19 19 Generator Maintenance 20 Service and Storage 21 Introduction Inspect Muffler and Spark Arrester Connecting to a Building s Electrical English Customer Service ...

Страница 4: ...iginal instructions for future reference Important Safety Information The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all inclusive If you use a procedure work method or operating technique that the manufacturer does not specifically recommend you must satis...

Страница 5: ...SAFETY PRECAUTIONS Page 02 POISONOUS GAS HAZARD English Customer Service 1 844 FIRMAN1 DANGER ...

Страница 6: ...ide and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Basement Crawl Space Living Area Attic Entry Way Porch Mudroom English Customer Service 1 844 FIRMAN1 ...

Страница 7: ...heck fuel lines tank cap and fittings frequently for cracks or leaks Replace if necessary DO NOT light a cigarette or smoke WHEN STARTING EQUIPMENT Ensure spark plug muffler fuel cap and air cleaner are in place DO NOT crank engine with spark plug removed WHEN OPERATING EQUIPMENT DO NOT operate this product inside any building carport porch mobile equipment or enclosure DO NOT tip engine or equipm...

Страница 8: ...amage generator and or electrical devices connected to it Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while...

Страница 9: ...l appliances Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency NOTE Improper treatment of generator could damage it and shorten its life UNPACKING THE GENERATOR Open carton and Remove packa...

Страница 10: ...ish Customer Service 1 844 FIRMAN1 1 2 Fuel Lever Vent Turn this valve to the On position to supply air to the tank 3 Fuel Cap 4 Control Panel 5 Recoil Starter 6 Muffler Spark Arrester 7 Spark Plug Access Cover 8 Maintenance Cover Oil filler and air filter access 9 Choke Knob 10 Engine ON OFF Switch 11 Economy Control Switch 12 Data Decal Serial Number Carrying Handle ...

Страница 11: ...s OFF when generator is overloaded 10 11 Choke Knob Economy Control Switch 12 The Economy Control switch can be activated in order to minimize fuel consumption and noise while operating the unit during times of reduced electrical output allowing the engine speed to idle during periods of non use The engine speed returns to normal when an electrical load is connected When the economy switch is off ...

Страница 12: ... and etc Maximum power decreases about 3 5 for each 1 000 feet above sea level and will also decrease about 1 for each 10 F 6 C above 60 F 16 C ambient temperature English Customer Service 1 844 FIRMAN1 Model Rated AC Voltage Phase Power Factor Voltage regulator Alternator Type Running Watts Starting Watts Engine Engine Type Displacement Low Oil Shutdown Ignition System Starting System Fuel Capaci...

Страница 13: ...sensor will activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an even surface to correct this If engine fails to start the oil level may not be sufficient to deactivate low oil level switch Make sure the sump is completely full of oil 5 Replace oil fill ca...

Страница 14: ...pors are extremely flammable and explosive which could cause burns fire or explosion resulting in death serious injury WHEN ADDING FUEL Fill fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion If the tank is overfilled fuel can overflow onto a hot engine and cause fire or explosion Wipe up any spilled fuel immediately If fuel spills wait until it evaporates before starting engin...

Страница 15: ... injury OPERATION Generator Location Make sure you review each warning in order to prevent fire hazard Keep area clear of inflammables or other hazardous materials Select a site that is dry well ventilated and protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING DANGER POISONOUS GAS HAZARD Eng...

Страница 16: ...n monoxide alarms with battery back up according to the manufacturer s instructions Smoke alarms cannot detect carbon monoxide gas DO NOT run this product inside homes garages basements crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even after this pro...

Страница 17: ...wly until resistance is felt and then pull rapidly to avoid kickback 8 Pull the starter cord slowly until resistance is felt and then pull rapidly English Customer Service 1 844 FIRMAN1 6 Pull the choke lever out to the START position 7 Flip the engine switch to the ON l position bones fractures bruises or sprains resulting in serious injury Connecting Electrical Loads 1 Let engine stabilize and w...

Страница 18: ...rical devices plugged in or turned on Let the generator run at no load for two minutes to stabilize internal temperatures of the engine and generator 2 Press the engine switch to the OFF O position WARNING If a cover is used do not install until unit has cooled Fuel and its vapors are extremely flammable and explosive which could cause burns fire or explosion resulting in death serious injury 3 Tu...

Страница 19: ...t load first 4 Allow the engine to stabilize 5 Plug in and turn on the next item 6 Allow the engine to stabilize 7 Repeat steps 5 6 for each additional item Overload Operation The overload indicator light will turn on when the load exceeds 1764W approximately If the load exceeds 1860W approximately the light will blink and cut power to the receptacles in 30 seconds Parallel Operation Two FIRMAN mo...

Страница 20: ...should clean or replace the spark plug and replace the air filter New spark plug and clean air filter assure proper fuel air mixture and help your engine run better and last longer ITEM NOTES Daily Before operation Initial 25 hours Every 50 hours Every 100 hours or annual Fittings Fasteners Spark Plug Engine Oil Air Filter Fuel Line Exhaust System Engine Check condition Adjust gap and clean Replac...

Страница 21: ...change oil after 25 hours Maintaining an air filter in proper condition is very important Dirt induced through improperly installed improperly serviced or inadequate elements damages and wears out engines Always keep the element clean d Put the element in the case and install it securely a Loosen the cover screws and remove the maintenance cover b Remove the oil filler cap dipstick c Tilt the gene...

Страница 22: ...emove the spark plug cover b Remove the spark plug cable from the spark plug NGK BPR6HS Champion RL87YC Torch E6RTC or equivalent DO NOT touch hot parts and AVOID hot exhaust gases Allow equipment to cool before touching Keep at least 5 feet 1 5 m of clearance on all sides of generator including overhead Replacement parts must be the same and installed in the same position as the original parts Cl...

Страница 23: ...a garden hose to clean the generator Water can enter the generator through the cooling slots and damage the generator windings Use a damp cloth to clean exterior surfaces of the generator Use a soft bristle brush to remove dirt and oil Use an air compressor 25 PSI to clear dirt and debris from the generator Inspect all air vents and cooling slots to ensure that they are clean and unobstructed 5 Re...

Страница 24: ...properly formulated stabilizers are not covered by manufacturer s warranty Drain fuel into approved container outdoors away from open flame Be sure engine is cool Do not smoke 4 FUEL STARVATION Start and run the generator until stops from lack of fuel This will dry out all remaining fuel in tank fuel lines and carburetor 7 Remove spark plug and pour about one teaspoon of engine oil through the spa...

Страница 25: ...pen or closed 13 Engine has lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner 5 Fill fuel tank 6 Drain fuel tank and carburetor fill with fresh fuel 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh fuel 1...

Страница 26: ...Page 23 PARTS DIAGRAM AND PARTS LIST W01784 Parts Diagram English Customer Service 1 844 FIRMAN1 ...

Страница 27: ...Page 24 80cc Engine Parts Diagram English Customer Service 1 844 FIRMAN1 ...

Страница 28: ...ridge Nut M5 Left Side Cover Assy Mounting Fuel Tank Fuel Tank Assy Fuel Filter Fuel Tank Cap Comp Maintenance Cover Holder Spark Plug Access Cover Maintenance Cover Filter tube Engine Buffer Bracket Fuel Tank Bolt M6 12 Bolt M5 20 Bridge Rectifier Control Module Clip Control Module Mounting Control Module Rubber Control Module Fuel Valve Cap Fuel Valve Box Flange Bolt M6 20 Fuel Hose 3 Chock Cabl...

Страница 29: ...Plug Stud Bolt M6 27 Muff Protector Assy Rh Nut Muff Comp Auspuffdichtung Protector Muff Side 9 1 5 1 1 2 1 2 1 1 10 2 1 1 1 2 4 1 1 1 1 1 2 1 2 1 1 1 4 1 1 1 1 1 1 2 1 1 1 1 1 2 2 1 6 4 1 1 2 1 1 1 317723552 317723553 317723554 317723555 317723556 317723557 317723558 317723559 317723560 317723561 317723562 317723563 317723564 317723565 317723566 317723567 317723568 317723569 317723570 317723571 3...

Страница 30: ...Wiring diagram Page 27 English Customer Service 1 844 FIRMAN1 ...

Страница 31: ...UCT Register your Firman generator online at www firmanpowerequipment com English Customer Service 1 844 FIRMAN1 WARRANTY FIRMAN Three 3 Year Limited Warranty Do Not Return the Unit to the Place of Purchase Contact the FIRMAN Service Center and FIRMAN will troubleshoot any issue via phone or e mail If the problem is not corrected by this method FIRMAN will at its option authorize evaluation repair...

Страница 32: ... accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any electrical component Normal maintenance is not covered by this warranty Other Exclusions This warranty excludes cosmetic defects such as paint decals etc wear items accessory parts failures due to acts of God and other force majeure events beyond the manufacturer s control problems c...

Страница 33: ...mately caused by a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part on your small off road engine and engine powered equipment is defective the part will be repaired or replaced by FIRMAN small off road engine and engine powered equipment The California...

Страница 34: ...ng Intake pipe manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting clamps FIRMAN POWER EQUIPMENT INC www firmanpowerequipment com 8 Throughout the emissions warranty period defined in Subsection b 2 FIRMAN will maintain a supply of warranted parts suffici...

Страница 35: ...Any reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT PEORIA AZ 85381 1 844 347 6261 WWW FIRMANPOWEREQUIPMENT COM 8716 W LUDLOW DR SUITE 6 P N 317745453 Rev 06 ...

Отзывы: