INTRODUCTION

 

English

 

3

 

Customer Service:  1-844-FIRMAN1

 

 

 

 

SIGNAL WORDS

 

   

DANGER 

 

WARNING 

 

CAUTION 

NOTICE

 

 

Indicates a hazard

 

 

Indicates a hazard

 

 

Indicates a hazard

 

 

Indicates information

 

which, if not avoided,

 

which, if not avoided,

 

which, if not avoided,

 

considered  Important,

 

will result in death or

 

could result in death

 

could result in minor or

 

but not hazard-related.

 

serious  injury.

 

or serious injury.

 

moderate  injury.

 

 

 

 

 

Safety Alert Symbol- Indicates a potential personal injury hazard.

 

 

Operator's Manual- Failure to follow warnings, instructions and 

operator's manual could result in death or serious injury.

 

 
 

Toxic Fumes- Engine exhaust contains carbon monoxide,  a 

poisonous gas that will kill you in minutes. You cannot smell 

it or see it.

 

 

 

Generator could cause electrical shock resulting in death or serious 

injury.

 

 

Fire- Fuel and its vapors are extremely flammable which could 

cause burns or fire resulting in death or serious injury.Engine 

exhaust could cause fire resulting in death or serious injury.

 

 

 

Hot Surface- Muffler could cause burns resulting in serious injury.

 

Содержание T07571

Страница 1: ...S MANUAL TRI FUEL PORTABLE GENERATOR MODEL NUMBER T07571 Rev Level 00 Record product information to reference when ordering parts or obtaining warranty coverage P N 375745471 Rev 02 NUMERO DE SERIE DATE D ACHAT ...

Страница 2: ...tains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended for any other purpose It is important that you read and understand these instructions thoroughly befo...

Страница 3: ... Indicates a potential personal injury hazard Operator s Manual Failure to follow warnings instructions and operator s manual could result in death or serious injury Toxic Fumes Engine exhaust contains carbon monoxide a poisonous gas that will kill you in minutes You cannot smell it or see it Generator could cause electrical shock resulting in death or serious injury Fire Fuel and its vapors are e...

Страница 4: ......

Страница 5: ...ervice This portable generator is designed to be used only with FIRMAN authorized parts System Ground The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles The system ground is connected to the AC neutral wire The neutral is bonded to the generator frame Compliance Requirements There may be Federal or State regulations l...

Страница 6: ...IS NOT RECOMMENDED DANGER Engine exhaust contains carbon monoxide a poisonous gas that will kill you in minutes You cannot smell it see it or taste it Even if you do not smell exhaust fumes you could still be exposed to carbon monoxide gas Extension cords running directly into the home increase your risk of carbon monoxide poisoning through any openings If an extension cord running directly into y...

Страница 7: ...ine 7 RecoilStarter 8 10 0 Flat Free Wheel 9 Oil Filler Cap 10 Battery 11 Outlet Cover 12 Control Panel 13 Handle 14 LPG NG Hose Connector Inlet 15 LPG NG Selector Switch 16 Hose Holder 17 LPG Hose with Regulator 18 ShortPowerCord L14 30Pto4X5 20R 19 Power Cord Holder We are always working to improve our products Therefore the enclosed product may differ slightly from the image on thispage ...

Страница 8: ...rotectors If the generator is overloaded or an external short circuit occurs a circuit protector may trip If tripping occurs disconnect all electrical loads and determine the cause before attempting to continue using the generator Reset any tripped circuit protectors If multiple receptacles are used at the same time the total current must be kept with in the portable generator nameplate rating 6 1...

Страница 9: ...sements crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even after this product has shut off If you start to feel sick dizzy weak or your home s carbon monoxide alarm sounds get to fresh air right away Call emergency services You may have carbon monoxid...

Страница 10: ...njury Keep portable generator at least 5 ft 1 5m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator indoors to protect it from the weather Do not locate the portable generator under a deck or other similar structure that may confine heat and airflow 5 ft 1 5m min 5 ft 1 5m min 20 ft 6m m...

Страница 11: ...ngine Use the chart to select the proper oil for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil Damage due to operation with no oil will void your warranty 1 Place generator on a flat level surface 2 Clean area around oil fill and remove yellow oil fill cap dipstick 3 Wipe dips...

Страница 12: ...t the oil level may not be high enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact Firman customer service Add Gasoline WARNING Fuel and its vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Turn generator engine OF...

Страница 13: ...ting Customer Support Installation instructions are also available in the Technical Bulletin area of the FIRMAN website www firmanpowerequipment com 439cc Altitude Altitude main jet 1 380717004 3000 6000Feet Altitude main jet 2 380717005 6000 8000Feet NOTICE Operation using an alternative main jet at elevations lower than the recommended minimum altitude can damage the engine For operation at lowe...

Страница 14: ...is a leak NOTICE LPG and NG systems must be installed and used in strict conformance with NFPA 58 Liquefied Petroleum Gas Code NFPA 54 National Fuel Gas Code manufacturers recommendations and comply with the authority having jurisdiction requirements To connect your generator to a large propane tank or Natural Gas Supply contact your gas equipment company or authority having jurisdiction to assure...

Страница 15: ...EEN If portable generator is not started during this 4 minute period the portable generator will switch to Battery Power Saving Mode to conserve battery life NOTICE Your portable generator is equipped with an internal battery charger that will properly charge the battery only when the engine is running The generator cannot be started in Battery Power Saving Mode Turn main fuel selector switch to t...

Страница 16: ...Indicator light Battery Power Saving Mode section for more information 5 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plugged in 6 Move choke lever located on engine to START position You do not need to choke a warm engine For electric start move to step 8 7 For recoil start only Pull the starter cord slowly until resistance is felt a...

Страница 17: ...ring operation check oil level See Low Oil Shutdown section for more information 4 Starting the Generator on LPG 1 Before starting the generator check for loose or missing parts and for any damage which may have occurred during shipment Ensure spark plug muffler fuel cap and air cleaner are all in place 2 Move portable generator outdoors to safe operating location at least 20 feet from any occupie...

Страница 18: ...the engine successfully anytime during the 4 minutes will turn the indicator light GREEN See Indicator light Battery Power Saving Mode section for more information 7 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plugged in 8 Move choke lever located on engine to START position For electric start move to step 12 9 For recoil start only ...

Страница 19: ...w seconds and then release 13 For electric start only Move the choke lever to the RUN position 14 Allow portable generator to run at no load for a few minutes to stabilize before plugging in any electrical devices NOTICE If engine starts but fails to run or if portable generator shuts down during operation check oil level See Low Oil Shutdown section for more information NOTICE Observing frost on ...

Страница 20: ...ust outlet The LPG cylinder and components can be temporarily warmed by pouring warm water over them 5 Starting the Generator on NG 1 Before starting the generator check for loose or missing parts and for any damage which may have occurred during shipment Ensure spark plug muffler fuel cap and air cleaner are all in place 2 Move portable generator outdoors to safe operating location at least 20 fe...

Страница 21: ...the engine successfully anytime during the 4 minutes will turn the indicator light GREEN See Indicator light Battery Power Saving Mode section for more information 7 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plugged in 8 Move choke lever located on engine to START position For electric start move to step 12 9 For recoil start only ...

Страница 22: ...ove choke lever to START position and repeat the PULL TO PRIME step 9 12 For electric start only Flip the engine switch to the START ll position for a few seconds and then release 13 For electric start only Move the choke lever to the RUN position 14 Allow portable generator to run at no load for a few minutes to stabilize before plugging in any electrical devices NOTICE If engine starts but fails...

Страница 23: ...acles Call Firman customer service If GFCI trips while in use reset and test the outlet Electric cords laying on the ground with worn insulation may trip the GFCI only use cords in good condition Receptacle Outlet LED Indicator Light RESET BUTTON TEST BUTTON Outlet SELF TEST OPERATION In addition to the manual test reset feature the GFCI receptacle tests itself periodically to confirm the GFCI ele...

Страница 24: ...for each additional item Surge Protection There is a remote chance that voltage fluctuations may impair the proper functioning of some sensitive electronic equipment Electronic devices including computers and many programmable appliances may use components that are designed to operate within a narrow voltage range and may be affected by the portable generator s momentary voltage fluctuations While...

Страница 25: ...English 23 Customer Service 1 844 FIRMAN1 OPERATION 2 Turn the main fuel selector switch to OFF O position 3 Fully close the LPG cylinder knob and NG source valve CLOSE ...

Страница 26: ...steners Check Replace if necessary To be performed by knowledgable experienced owner or by authorized service center General R e c o m m e n d a t i o n s Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjected to operator abuse or negligence To receive full va...

Страница 27: ...eather change the oil more often CAUTION Avoid prolonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS a On a level surface drain oil into a suitable container by removi...

Страница 28: ...dry in a clean cloth b Saturate foam air filter element with clean engine oil and squeeze in a clean cloth to remove excess oil c Reinstall clean or new air filter element Spark Plug Maintenance Changing the spark plug will help your engine start easier and run at peak performance a Remove the spark plug boot b Remove spark plug using provided wrench A Spark plug B Spark plugboot A B ...

Страница 29: ... 17 mm 0 005 0 007 i n Exhaust 0 18 0 22 mm 0 007 0 009 in NOTICE Tech bulletin regarding the valve adjustment procedure is on www firmanpowerequipment com Muffler and Spark Arrester WARNING Contact with muffler area could cause burns resulting in serious injury Do not tough hot parts It is a violation of California Public Resource Code Section 4442 to use or operate the engine on any forest cover...

Страница 30: ...he spark arrester in the muffler and attach with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Run the generator at least 30 minutes every month Make certain that the portable generator is kept clean and dry Do not expose the unit to excessive dust dirt moisture or corrosive vapors Do not insert any objects through coo...

Страница 31: ...attery powers the starter motor and control module This portable generator is equipped with an automatic battery charging circuit The battery will receive charging voltage only when the engine is running The battery will maintain a proper charge if the portable generator is used on a regular basis about once every two weeks If it is used less frequently the battery should be connected to a trickle...

Страница 32: ...e shutdown 3 There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained turn main fuel selector switch to GAS position Start and run the portable generator outdoors until engine stops from lack of gasoline This will drain remaining gasoline from tank fuel lines and c...

Страница 33: ...5 LPG cylinder knob NG supply valve is notopen 16 Out of battery power 1 Set fuel selector switch to GAS or LPG NG position 2 Musthavesolidredindicatorlight tobeabletostartthe engine 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner 5 Fill fuel tank with gasoline 6 Drain fuel tank and carburetor fill with fresh gasoline 7 Connect wire to spark plug...

Страница 34: ...n Type Flywheel Magneto StartingSystem Recoil Electric Start Fuel UnleadedAutomotiveGasoline LPG NG Capacity FuelTank 8 0 U S Gallons 30 3L LubricatingOil Capacity 37 2 oz 1 1L Carburetor Type Float Air Cleaner Polyurethane Type P T O Shaft Rotation Counter Clockwise Facing P T O Oil Type See Add Engine Oil Section AC Grounding System Neutral Bonded To Frame Natural gas fuel pressure range 7 11 in...

Страница 35: ...English 33 Customer Service 1 844 FIRMAN1 PARTS DIAGRAM AND PART LIST T07571 PARTS DIAGRAM 156 English 33 Customer Service 1 844 FIRMAN1 ...

Страница 36: ...439cc TRI FUEL ENGINE PARTS DIAGRAM English 34 Customer Service 1 844 FIRMAN1 ...

Страница 37: ...3503 Spark Arrestor Kit 1 147 357413506 Support Leg Assembly 1 148 336713691 Hose Holder 1 149 380413512 LPG NG Selector switch assembly 1 150 380713542 Screw washer Assy M3 6 4 151 380713562 Screw washer Assy M5 8 4 152 357713607 Battery cable Male 180mm 1 153 360417010 Power Cord Holder 1 154 360457024 Short Power Cord 1 155 380727001 Cover 1 156 336713834 Regulator Hose Assy 1 NO Part Number De...

Страница 38: ...Gasket Set 1 112 336723615 Lock Washer 2 113 375717008 Washer 1 NO Part Number Description Qty 1 380723518 Crankcase Comp 1 2 357723501 Bolt drain 2 3 357723502 Washer drain Bolt 2 4 357723503 Oil Level Sensor 1 5 357723504 Flg Bolt M6 15 2 6 357723505 Bearing 2 7 316713518 Locating Pins 2 8 357723506 Bearing 2 9 357723507 Balance Shaft 1 10 357723508 Camshaft Comp 1 11 380723501 Crankshaft 1 12 3...

Страница 39: ...Parts Diagrams Parts Lists Wiring Diagram English 37 Customer Service 1 844 FIRMAN1 ...

Страница 40: ...lectrical components will be free of defects in material and workmanship for a period of one 1 year parts and labor and three 3 years parts and technical support from the original date of purchase 90 days parts and labor and 180 days parts for commercial industrial use Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purch...

Страница 41: ... cover any loss of time use of this product freight or any incidental or consequential claim by anyone from using this product THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANT ABLILITY OR FITNESS FOR A PARTICULAR PURPOSE A unit provided as an exchange will be subject to the warranty of the original unit The length of the warranty governing the ex...

Страница 42: ...quipment to a FIRMAN distribution center or service center as soon as the problem exists The warranty repairs shall be completed in a reasonable amount of time not to exceed 30 days If you have any questions regarding your warranty rights and responsibilities you should contact FIRMAN at 1 844 347 6261 or support firmanpowerequipment com FIRMAN Emission Control Defects Warranty Provisions The warr...

Страница 43: ...are the parts if equipped covered by the Federal and California Emission Control System Warranty Limitations This Emission Control System Warranty shall not cover any of the following a Consequential damages such as loss of time inconvenience loss of use of the engine or equipment etc b Diagnosis and inspection fees that do not result in eligible warranty service being performed FIRMAN POWER EQUIP...

Страница 44: ...English 42 Customer Service 1 844 FIRMAN1 Service Warranty All rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited P N 375745471 Rev 02 ...

Отзывы: