Operation Manual of Diesel Generator
6. Operating Your Generator Set
6-1 Operating your generator
(1)
Warm up the engine without load for 3 minutes.
(2)
CX series generator is equipped with low oil warning system. The engine will stop
automatically in case of low oil pressure or a lubrication oil shortage. The engine will stop
immediately without a lubrication oil refill. Check the oil level and refill.
(3)
Do not loosen or readjust either the engine speed limiting bolt or fuel injection limiting bolt
(They had been already well adjusted before leaving factory), otherwise performance may
be affected.
6-2 Checks during operation
(1)
Any abnormal sound or vibration?
(2)
The engine misfiring or running rough?
(3)
What about the color of the exhaust gas? (Is it black or too white?).
If you notice any situation mentioned above, please contact your dealer.
6-3 Load
To add load according to specified parameter.
A.C application
(1) Set AC breaker to “ON”. Pilot lamp will illuminate, the speed of generator must reach rated
speed (lever at top).
(2) Insert the receptacle with the plugs of electric instruments to be connected, keep the
switches of the connected electric instruments to “OFF”.
CAUTION
The instruments which require much starting current and some kinds of motors may be
unable to be use even if they are within the applicable scope.
The circuit breaker turns “OFF” when the current exceeding the applicable scope is used or
when the applied instrument is defective.
The current of the instruments which should not exceed the rated current showed on the
socket, or else it may damage the machine.
DC application
(1)
When the instruments connect with the DC terminal, please make sure to the positive
polarity.
(2)
DC output 12V 8.3A – 100W.