Firman R-P03608 Скачать руководство пользователя страница 29

Page 27

WARNING

SERVICE AND STORAGE

Infrequent Service

If the unit is used infrequently, difficult starting

may result. To eliminate hard starting, follow

these instructions:

1. Run the generator at least 30 minutes every

month.

2. Run the generator, then close the fuel shut-off

valve and allow the unit to run until the engine

stops.

3. Move the engine switch to the "OFF" position.

ALWAYS connect the positive (+) battery cable

(red boot) first when connecting battery cables.

ALWAYS disconnect the negative (-) battery

cable (black boot) first when disconnecting

battery cables.

NEVER connect the negative (-) battery cable

(black boot) to the positive (+) post on the

battery.

NEVER connect the positive (+) battery cable

(red boot) to the negative (-) post on the battery.

NEVER touch both battery posts simultaneously.

NEVER place a metal tool across both battery

posts.

ALWAYS use insulated or nonconducting tools

when installing the battery.

To avoid electric shock:

Battery Replacement On Remote

Lithium Battery

1. Loosening and remove cover screws.

2. Remove the cover.

3. Remove the depleted batteries and insert

two new CR2016 lithium batteries with the

“+ ” terminal facing up.

4. Close the remote cover and tight the screws.

English

DANGER

Long Term Storage

It is important to prevent gum deposits from forming

in essential fuel system parts such as the carburetor,

fuel  hoses  or  tank  during  storage.  Also,  experience

indicates that alcohol-blended fuels (called gasohol,

ethanol or methanol) can attract moisture, which leads

to separation and formation of acids during storage.

Acidic gas can damage the fuel system of an engine

while in storage.

When the generator set is not being operated, or

is being stored for more than one month, follow

these instructions to avoid engine problems:

1-ADD a properly formulated commercially  FUEL

STABILIZER to the tank if it is not already added.
2-Operate the engine for 5-10 minutes to circulate

treated fuel into fuel lines and carburetor before

3- After engine cools down, remove all gasoline

from the fuel tank. Use a commercially available,

non-conductive vacuum siphon.

shutdown.

Drain fuel into approved container outdoors,

away from open flame. Be sure engine is cool.

Do not smoke.

4-FUEL STARVATION:  Start and run the generator

until it stops from lack of fuel. This will dry out all

remaining  fuel  in  tank,  fuel  lines  and  carburetor.

7-Remove spark plug and pour about one teaspoon

of engine oil through the spark plug hole, then pull

the recoil starter several times to distribute the oil for

lubricating  the  cylinder.  Reattach  the  spark  plug.

Pull  recoil  slowly  until  resistance  is  felt.  This  will

close  the  valves  so  moisture  cannot  enter  engine

cylinder. Gently release recoil starter.

5-Allow the unit to cool entirely before cleaning

and storage.

6-Change oil with recommended grade oil.

Содержание R-P03608

Страница 1: ...ing equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage MODEL...

Страница 2: ...tart 18 Starting the Generator Electric Start 19 Starting the Generator Remote Start 20 Connecting Electrical Loads 21 Stopping the Engine 21 Low Oil Shutdown 22 Do Not Overload Generator 22 Introduct...

Страница 3: ...cts and how to avoid them This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended...

Страница 4: ...duct downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizzy or weak while using this product shut it off and get to fresh air RIGHT AWAY See a doctor You may h...

Страница 5: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Страница 6: ...and and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury When starting engine pull cord slowly until resistance is f...

Страница 7: ...loads OFF and disconnect from generator before stopping generator DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or we...

Страница 8: ...old depends on electrical equipment to live Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency NOTE Improper t...

Страница 9: ...r warranty Refer to the following instructions and pictures to remove the attached engine support brackets red under the engine 3 You may discard these brackets as it is no longer required for normal...

Страница 10: ...ssembly prior to usage If these items are included follow directions below Install the Wheel Kit H K 1 Before adding wheels tip the generator on its side 2 Slide the axle pinA through the wheel B 3 Sl...

Страница 11: ...battery cable red boot is securely tightened to the positive battery post Make sure boot is over battery post 2 Remove bolt M5X10 and M5 nut from black cable ring 3 Remove vinyl cap from the negative...

Страница 12: ...ge 1 Fuel Gauge 2 5 0 Gallon Capacity Fuel Tank 3 Fuel Cap 4 Choke Lever behind air filter box 5 Fuel Valve 6 A ir Filte r 7 208cc FIRMAN OHV Engine 8 Recoil Starter 9 Bottle Opener 10 Remote Holder T...

Страница 13: ...ust and debris 10 11 Page 11 NOTE Total power drawn from all receptacles must not exceed the name plate rating Engine Start Switch Used to start engine from the starter motor Electric start model only...

Страница 14: ...ip the engine switch to the RUN l position 2 Flip the battery switch to the ON l position 3 Push and hold the program button on the control panel for approximately 3 seconds The remote start indicator...

Страница 15: ...eakless Ignition Type Flywheel Magneto Unleaded Automotive Gasoline 5 0 Gallon 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4550 FIRMAN Rated Fequency 60Hz Oil Type...

Страница 16: ...quired the sensor will activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil t...

Страница 17: ...ed fuel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engin...

Страница 18: ...O NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator Connecting...

Страница 19: ...and protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation...

Страница 20: ...NG When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 8 Pull the starter cord slowly until resistance is...

Страница 21: ...and fuel 3 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plugged in or turned on 4 Turn the fuel valve to the ON l position 5 Flip the en...

Страница 22: ...READY TO START THE GENERATOR If the remote control is replaced then you will need to go through programming procedure in Remote Control Programming section 3 Disconnect all electrical loads from the...

Страница 23: ...e speed adjusted at the factory for correct output Readjusting will void warranty CAUTION When applying a load do not exceed the maximum wattage rating of the generator when using one or more receptac...

Страница 24: ...heck oil level with dipstick If oil level is between LOW and HIGH mark on dipstick 1 DO NOT try to restart the engine 2 Contact an Authorized FIRMAN Service Dealer 3 DO NOT operate engine until oil le...

Страница 25: ...commendations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been s...

Страница 26: ...certain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours fo...

Страница 27: ...rainer cup with gasoline c Tightly fasten the cup to main body making sure to avoid fuel leak SCREEN O ring CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and clean w...

Страница 28: ...surfaces of the generator Use a soft bristle brush to remove dirt and oil Use an air compressor 25 PSI to clear dirt and debris from the generator Inspect all air vents and cooling slots to ensure th...

Страница 29: ...em parts such as the carburetor fuel hoses or tank during storage Also experience indicates that alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation...

Страница 30: ...tabilizer A FUEL STABLIZER will minimize the formula tion of fuel gum deposits during storage the fuel stabilizer can be added to the gasoline in the fuel tank or into the gasoline in a storage contai...

Страница 31: ...resh fuel 7 Connect wire to spark plug 8 Replacespark plug 9 Drain gas tank and carburetor fill with fresh fuel 10 Wait 5 minutes and re crank engine 11 Contact authorized servicefacility 12 Contact a...

Страница 32: ...Page 30 PARTS DIAGRAM AND PART LIST P03608 PARTS DIAGRAM English 125...

Страница 33: ...Page 31 208cc ENGINE PARTS DIAGRAM English...

Страница 34: ...Flange Bolt M6 179 Lock Washer 6 Flat Washer 6 Ground Wire Flange Bolt M6 12 Nut M6 AVR Flange Bolt M5 16 Bolt washer Assemblies Generator End Cover Cap Ground Wire Terminal Block Bolt washer Assembli...

Страница 35: ...tor Gasket Carburetor Carburetor Gasket Air Cleaner Nut M6 Elbow Air Cleaner Clapboard Cover Subassembly Cylinder Head Gasket Cylinder Head Cover Plate Subassembly Lifter Stopper Head Subassembly Cyli...

Страница 36: ...your name and address and a description of the defect 3 Ship to the address provided by ARC 4 Write the RMA number provided on the outside of the package What Your Warranty Does Not Cover Improper ins...

Страница 37: ...gine is Designed built and equipped so as to conform with all applicable regulations adopted by the Air Resources Board and US EPA and Free from defects in materials and workmanship that cause the fai...

Страница 38: ...old Catalytic converter Muffler gasket pulse valve 4 Air induction system including Intake pipe manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evapor...

Отзывы: