Firman P09201 Скачать руководство пользователя страница 30

SPECIFICATIONS

Model

 

Rated AC Voltage

 

 

Phase

 

Power Factor

 

 

Voltage Regulator

 

Alternator

 

Type

 

Running Watts*

 

Starting Watts 

 

Engine

 

 

Engine Type

 

 

Displacement

 

Low Oil Shutdown

Ignition System

 

 

Starting System

 

 

Fuel

 

Capacity 

 

Fuel Tank

 

Lubricating Oil

 

 

 Capacity

 

Carburetor

 

Type

 

Air

 

Cleaner

 

P.T.O. Shaft Rotation

 

120/240V

 

P09201

9200

AVR

 

Single 

1

Single Cylinder, 4-Stroke OHV Air Cooled

459cc

 

Breakless Ignition Type, Flywheel Magneto 

Unleaded

Automotive

Gasoline

 

 

9 U.S. Gallons (34L)

37.2 oz (1.1L)

Counter Clockwise (Facing P.T.O.)

Float

 

Brushed

Polyurethane Type

Yes 

11400

FIRMAN

Rated Fequency

60Hz

 

Oil Type

 

See “Add Engine Oil” Section

Recoil/Electric Start

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

AC Grounding System

Neutral Bonded To Frame

29

Troubleshooting – Specifications

*

Generator certified in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-14, 

Motors and Generators.

Содержание P09201

Страница 1: ...P N 392745450 Rev 00 GASOLINE PORTABLE GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER P09201 Rev Level 00 OPERATOR S MANUAL...

Страница 2: ...ntains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supplying electrical powe...

Страница 3: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Страница 4: ...erator is designed to be used only with FIRMAN authorized parts FIRMAN The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacl...

Страница 5: ...ED Extension cords running directly into the home increase your risk of carbon monoxide poisoning through any openings If an extension cord running directly into your home is used to power indoor item...

Страница 6: ...1 Fuel Gauge 2 9 0 Gallon 34L Capacity Fuel Tank 3 Fuel Cap 5 Fuel Valve 6 Air Filter 7 459cc FIRMAN OHV Engine 8 Recoil Starter 9 11 0 28cm Flat Free Wheel 10 Oil Filler Cap 11 Outlet Cover 12 Contr...

Страница 7: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS...

Страница 8: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS...

Страница 9: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS...

Страница 10: ...grounding requirements 2 3 4 5 9 10 11 1 6 7 8 12 13 3 Battery Switch Power the electric starter 4 Remote Start Indicator Light The light will light or flash depending on the status of the remote star...

Страница 11: ...crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even...

Страница 12: ...able generator at least 5 ft 1 5 m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator in...

Страница 13: ...art to select the proper oil for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oi...

Страница 14: ...enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact FIRMAN custom...

Страница 15: ...ative main jet and installation instructions can be obtained by contacting customer service NOTICE Operation using an alternative main jet at elevations lower than the recommended minimum altitude can...

Страница 16: ...2 Move portable generator outdoors to safe operating location at least 20 ft 6 m from any occupied spaces 15 OPERATION 3 Disconnect all electrical loads from the generator Never start or stop the gen...

Страница 17: ...apidly 10 Do not over choke As soon as engine starts and warms up move the choke lever to the RUN position 11 Push and release the START button on the remote control 3 to 5 seconds and start The gener...

Страница 18: ...r service If GFCI trips while in use reset and test the outlet Electric cords laying on the ground with worn insulation may trip the GFCI only use cords in good condition RESET TEST TEST MONTHLY FOLLO...

Страница 19: ...th the largest load first 5 Allow the engine to stabilize 6 Plug in and turn on the next item 7 Allow the engine to stabilize 8 Repeat steps 5 6 for each additional item Surge Protection There is a re...

Страница 20: ...show CO ALERT is functioning properly TM Carbon monoxide accumulated around generator Prior to restart move generator to an open outdoor area 20 ft 6 m from occupied spaces with exhaust pointed away...

Страница 21: ...off Skip this step and go to step 3 if you are not using Remote Start to shut down the engine Flip the engine switch to OFF O position STOP 3 Electric Start and Recoil Start Operations 4 Flip the batt...

Страница 22: ...he spark plug and replace the air filter New spark plug and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable...

Страница 23: ...olonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REAC...

Страница 24: ...a clean cloth b Saturate foam air filter element with clean engine oil and squeeze in a clean cloth to remove excess oil Spark Plug Maintenance Changing the spark plug will help your engine start easi...

Страница 25: ...ARNING Contact with muffler area could cause burns resulting in serious injury Do not tough hot parts It is a violation of California Public Resource Code Section 4442 to use or operate the engine on...

Страница 26: ...ffler and attach with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Make certain that the portable generator is kept cle...

Страница 27: ...provided 9 Install the spark plug boot onto spark plug The battery powers the starter motor and control module This portable generator is equipped with an automatic battery charging circuit The batter...

Страница 28: ...wn 3 There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained tur...

Страница 29: ...soline 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh gasoline 10 Wait 5 minutes and re crank engine 11 Contact authorized service facility Engine la...

Страница 30: ...e Cylinder 4 Stroke OHV Air Cooled 459cc Breakless Ignition Type Flywheel Magneto Unleaded Automotive Gasoline 9 U S Gallons 34L 37 2 oz 1 1L Counter Clockwise Facing P T O Float Brushed Polyurethane...

Страница 31: ...PARTS DIAGRAM AND PART LIST P09201 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 30...

Страница 32: ...459cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 31...

Страница 33: ...l Head Bolt M8 60 Nut M8 Bolt M8 16 1 2 1 1 1 1 1 1 1 1 1 1 1 3 1 2 1 1 2 4 2 2 1 1 1 2 1 1 1 1 9 1 1 3 1 2 1 7 2 1 1 1 1 1 1 1 1 2 4 2 NO Part Number Description Qty 36 36 1 36 2 36 3 36 4 37 38 39 4...

Страница 34: ...lt M3 6 Rectifier Bridge Charger Control Module Nut M3 Multi Meter Bolt M5 12 CO Alarm Remote Holder Remote Control Engine Switch Battery Switch Indicator Light Bolt M6 22 Flat Washers Spring Pad Nut...

Страница 35: ...Comp Camshaft Comp Valve Lifter Push Rod 3 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 5 1 1 1 2 10 2 1 1 2 2 1 1 1 2 1 2 1 1 2 2 1 5 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 2 1 2 4 1 1 1 1 1 2 2 55 56 57 57 1 57 2 57 3 57...

Страница 36: ...English Customer Service 1 844 FIRMAN1 35 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Страница 37: ...pt of your Warranty Registration Card and a copy of your sales receipt from one of FIRMAN s retail locations as proof of purchase Please submit your warranty registration and your proof of purchase wi...

Страница 38: ...stallation Use and Maintenance This warranty will not apply to parts and or labor if your product is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s...

Страница 39: ...a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part o...

Страница 40: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Страница 41: ...l rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT INC 8716 W Ludlow Dr Suite 6 www firmanpowerequipment com Peoria A...

Отзывы: