English Customer Service: 1-844-FIRMAN1
09
FEATURES AND CONTROLS
Control Panel
6.
120/240V, 50A
– (NEMA 14-50R)
(Not GFCI protected)
A maximum of 33.3 Amps current for 240 Volts or two independent 120 Volt loads at 33.33 Amps current each.
7.
120/240V, 30A Twist Lock
– (NEMA L14-30R)
(Not GFCI protected)
NOTICE
Total power drawn from all receptacles must not exceed the data decal rating.
A maximum of 30 Amps current for 240 Volts or two independent 120 Volt loads at 30 Amps current each.
8.
120V, 30A Twist Lock
– NEMA L5-30R(Not GFCI protected)
A maximum of 30 Amps current may be drawn from this receptacle.
9.
120V, 20A Duplex GFCI
(Ground Fault Circuit Interrupter)- NEMA 5-20R
A maximum of 20 Amps current may be drawn from this duplex receptacle.
1.
Engine Start Switch
– To start engine, press and hold the switch in the START (ll) position, the
engine will crank and attempt to start. When the engine starts, release the switch to the RUN (l) position.
2.
4-1 Data-Minder (Multi-Meter)
– Push the SELECT button to show the Voltage, Hertz, running hours and
low oil alarm.
10.
Ground Terminal
– Consult an electrician or authority having jurisdiction for local grounding
requirements.
3.
Battery Switch
– Power the electric starter.
4.
Remote Start Indicator Light
- The light will light or flash depending on the status of the remote start
system.
5.
Remote Start Program Button
- Use this button along with the remote control to program the
generator to be started remotely. Your remote control is already programmed in factory for your
convenience. If remote start control is ever replaced you may need to program. Contact FIRMAN
customer service.
11.
Outlet Cover -
Protect
the
receptacles from dust and debris.
12.
Circuit Breakers
– The receptacles are protected by AC circuit protectors. If the generator is
overloaded or an external short circuit occurs, a circuit protector may trip. If tripping occurs,
disconnect all electrical loads and determine the cause before attempting to continue using the
generator. Reset any tripped circuit protectors.
If multiple receptacles are used at the same time, the total current must be kept with-in the
portable generator
data decal
rating.
2
3
4
5
9
10
11
1
6
7
8
12
12
12
13
13.
CO Alert™ Carbon Monoxide (CO) Shutdown Indicator Light
— Indicates the engine shutdown due
to carbon monoxide accumulation around the generator or a CO Alert system fault occurred.
Содержание P08008
Страница 7: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS ...
Страница 8: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS ...
Страница 9: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS ...
Страница 31: ...PARTS DIAGRAM AND PART LIST P08008 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 30 ...
Страница 32: ...439cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 31 ...
Страница 37: ...English Customer Service 1 844 FIRMAN1 36 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram ...