Firman P08004 Скачать руководство пользователя страница 28

Page 26

WARNING

SERVICE AND STORAGE

Infrequent Service

If the unit is used infrequently, difficult starting 
may result. To eliminate hard starting, follow 
these instructions:
1. Run the generator at least 30 minutes every 
    month.
2. Run the generator, then close the fuel shut-off 
    valve and allow the unit to run until the engine 
    stops.
3. Move the engine switch to the "OFF" position.

ALWAYS

 connect the positive (+) battery cable 

(red boot) first when connecting battery cables.

ALWAYS

 disconnect the negative (-) battery 

cable (black boot) first when disconnecting 
battery cables.

NEVER

 connect the negative (-) battery cable 

(black boot) to the positive (+) post on the 
battery.

NEVER

 connect the positive (+) battery cable 

(red boot) to the negative (-) post on the battery.

NEVER

 touch both battery posts simultaneously.

NEVER

 place a metal tool across both battery 

posts.

ALWAYS 

use insulated or nonconducting tools 

when installing the battery.

To avoid electric shock:

Battery Replacement On Remote

Lithium Battery

1. Loosening and remove cover screws.
2. Remove the cover.
3. Remove the depleted batteries and insert 
    two new CR2016 lithium batteries with the 
    “

+

” terminal facing up.

4. Close the remote cover and tight the screws.

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

DANGER

Long Term Storage

It is important to prevent gum deposits from forming 
in essential fuel system parts such as the carburetor, 
fuel  hoses  or  tank  during  storage.  Also,  experience 
indicates  that  alcohol-blended  fuels  (called  gasohol, 
ethanol or methanol) can attract moisture, which leads 
to separation and formation of acids during storage. 
Acidic gas can damage the fuel system of an engine 
while in storage.
When the generator set is not being operated, or 
is being stored for more than one month, follow 
these instructions to avoid engine problems:
1-

ADD

 a properly formulated commercially 

FUEL 

STABILIZER

 to the tank if it is not already added.

2-Operate the engine for 5-10 minutes to circulate 
treated  fuel  into  fuel  lines  and  carburetor  before 

3- After engine cools down, remove all gasoline 
from the fuel tank. Use a commercially available, 
non-conductive vacuum siphon.

shutdown.

Drain fuel into approved container outdoors, 
away from open flame. Be sure engine is cool. 
Do not smoke.

4-

FUEL STARVATION:

  Start and run the generator 

until it stops  from lack of fuel. This will dry out all 
remaining  fuel  in  tank,  fuel  lines  and  carburetor.

7-Remove spark plug and pour about one teaspoon 
of engine oil through the spark plug hole, then pull 
the recoil starter several times to distribute the oil for 
lubricating  the  cylinder.  Reattach  the  spark  plug. 
Pull  recoil  slowly  until  resistance  is  felt.  This  will 
close  the  valves  so  moisture  cannot  enter  engine 
cylinder. Gently release recoil starter.

5-Allow the unit to cool entirely before cleaning 
and storage.  

6-Change oil with recommended grade oil.

Содержание P08004

Страница 1: ...and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage Serial Number PORTABLE GENERATOR MODEL NUMB...

Страница 2: ...lectric Start 18 Starting the Generator Remote Start 19 Connecting Electrical Loads 20 Stopping the Engine 20 Low Oil Shutdown 21 Do Not Overload Generator 21 Introduction Battery Cable Connection Con...

Страница 3: ...mation The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all...

Страница 4: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD English Customer Service 1 844 FIRMAN1...

Страница 5: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Страница 6: ...ns fire or explosion resulting in death or serious injury and or property damage WHEN ADDING OR DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loos...

Страница 7: ...T handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING Exhaus...

Страница 8: ...edical devices or medical appliances Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live Inform your electrical provider immediately...

Страница 9: ...C F The generator requires some assembly prior to usage If problems arise when assembling the generator call 1 844 347 6261 F E G H K 1 Before adding wheels tip the generator on its side 2 Slide the...

Страница 10: ...nnection NOTE The generator comes equiped with the positive red and negative black cables already attached to battery terminals 1 Cut wire tie that is binding the black battery cables A and B 2 Insert...

Страница 11: ...gine 8 Recoil Starter 9 10 0 Flat Free Wheel 10 Oil Filler Cap 11 Outlet Cover 12 Control Panel 13 Handle 14 Battery 15 Remote Holder English Customer Service 1 844 FIRMAN1 We are always working to im...

Страница 12: ...voltage indicator C Frequency indicator D Hour indicator E Low oil indicator F Select button English Customer Service 1 844 FIRMAN1 2 3 4 5 1 120V 30A Twist Lock NEMA L5 30R 120 240V 30A Twist Lock N...

Страница 13: ...rained Remote Control Programming 1 Flip the engine switch to the RUN l position NOTE YOUR REMOTE CONTROL IS ALREADY PROGRAMMED IN FACTORYFORYOURCONVENIENCE ANDITISREADYTO STARTTHEGENERATOR Before the...

Страница 14: ...hase Power Factor Voltage Regulator Alternator Type Running Watts Starting Watts Engine Engine Type Displacement Low Oil Shutdown Ignition System Starting System Fuel Capacity Fuel Tank Lubricating Oi...

Страница 15: ...l activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an e...

Страница 16: ...k Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or wipe up any sp...

Страница 17: ...erwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqual...

Страница 18: ...the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may impair the prop...

Страница 19: ...ine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 8 Pull the starter cord slowly until resistance is felt and then pull r...

Страница 20: ...ct all electrical loads from the generator Never start or stop the generator with electrical devices plugged in or turned on 4 Turn the fuel valve to the ON l position 5 Flip the engine switch to the...

Страница 21: ...CONVENIENCE ANDITISREADYTO STARTTHEGENERATOR If the remote control is replaced then you will need to go through programming procedure in Remote Control Programming section 3 Disconnect all electrical...

Страница 22: ...ill void warranty CAUTION When applying a load do not exceed the maximum wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle...

Страница 23: ...op the engine Check oil level with dipstick If oil level is between LOW and HIGH mark on dipstick 1 DO NOT try to restart the engine 2 Contact an Authorized FIRMAN Service Dealer 3 DO NOT operate engi...

Страница 24: ...ould clean or replace the spark plug and replace the air filter New spark plugs and clean air filter assure proper fuel air mixture and help your engine run better and last longer ITEM NOTES Daily Bef...

Страница 25: ...ry animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a new engine c...

Страница 26: ...ng CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and clean with a wire brush before reinstalling Inspect Muffler and Spark Arrester Inspect the muffler for cracks co...

Страница 27: ...xterior surfaces of the generator Use a soft bristle brush to remove dirt and oil Use an air compressor 25 PSI to clear dirt and debris from the generator Inspect all air vents and cooling slots to en...

Страница 28: ...sential fuel system parts such as the carburetor fuel hoses or tank during storage Also experience indicates that alcohol blended fuels called gasohol ethanol or methanol can attract moisture which le...

Страница 29: ...s using a fuel stabilizer A FUEL STABLIZER will minimize the formula tion of fuel gum deposits during storage the fuel stabilizer can be added to the gasoline in the fuel tank or into the gasoline in...

Страница 30: ...tank and carburetor fill with fresh fuel 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh fuel 10 Wait 5 minutes and re crank engine 11 Contact author...

Страница 31: ...Page 29 PARTS DIAGRAM AND PART LIST P08004 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1...

Страница 32: ...Page 30 English Customer Service 1 844 FIRMAN1 439cc ENGINE PARTS DIAGRAM...

Страница 33: ...74 75 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130...

Страница 34: ...buretor Gskt carb Carburetor Choke Connector 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 10...

Страница 35: ...Warranty Do Not Return the Unit to the Place of Purchase Contact the FIRMAN Service Center and FIRMAN will troubleshoot any issue via phone or e mail If the problem is not corrected by this method FI...

Страница 36: ...apply to parts and or labor if your product is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected inc...

Страница 37: ...failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part on y...

Страница 38: ...ld Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting clamps FI...

Страница 39: ...P N 380745453 Rev 04 Firman Power Equipment Inc Peoria AZ 85381 www firmanpowerequipment com 8716 West Ludlow Dr Suite 6...