Firman P04001 Скачать руководство пользователя страница 4

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

WARNING!  This  product  can  expose  you  to  chemicals  including  gasoline  engine 
exhaust,  which  is  known  to  the  State  of  California  to  cause  cancer,  and  carbon 
monoxide, which is known to the State of California to cause birth defects or other 
reproductive harm.  For more information go to www.P65Warnings.ca.gov.

This outdoor generator can be used to power outdoor items using extension cords .

NOTICE

 If you have questions about intended use, contact 

 customer service. This portable 

generator is designed to be used only with FIRMAN authorized parts.

FIRMAN

There may be Federal or State regulations, local codes, or ordinances that apply to the intended 
use of the generator. Consult a qualified electrician, electrical inspector, or the local agency 
having jurisdiction. This generator is not intended to be used at a construction site or similar 
activity as defined by NFPA 70-2020 (NEC) section 590.6.

Compliance Requirements

To Restore Power Using Extension Cords

03

INTRODUCTION

The generator neutral is floating, which means that the AC stator winding is isolated from the
grounding fastener and the AC receptacle ground pins. On a floating neutral generator the AC 
receptacle ground pins are not functional. Electrical devices, such as a ground fault circuit 
interrupter (GFCI), requiring a functioning AC receptacle ground pin will not operate.

System Ground

Содержание P04001

Страница 1: ...P N 340745450 Rev 03 OPERATOR S MANUAL GASOLINE PORTABLE GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER P04001 Rev Level 00...

Страница 2: ...upport This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supp...

Страница 3: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Страница 4: ...may be Federal or State regulations local codes or ordinances that apply to the intended use of the generator Consult a qualified electrician electrical inspector or the local agency having jurisdict...

Страница 5: ...ing through any openings If an extension cord running directly into your home is used to power indoor items the operator recognizes that this increases the risk of CO poisoning to people inside the ho...

Страница 6: ...OLS 1 Fuel Gauge 2 6 0 Gallon Capacity Fuel Tank 3 Fuel Cap 4 5 6 7 8 Air Filter 223cc FIRMAN OHV Engine Recoil Starter Bottle Opener Remote Holder The remote controller can be placed inside the remot...

Страница 7: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS...

Страница 8: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS...

Страница 9: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS...

Страница 10: ...ctrician or authority having jurisdiction for local grounding requirements 10 Outlet Cover Protects the receptacles from dust and debris 8 Circuit Breakers The receptacles are protected by AC circuit...

Страница 11: ...crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even...

Страница 12: ...able generator at least 5 ft 1 5 m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator in...

Страница 13: ...art to select the proper oil for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oi...

Страница 14: ...enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact Firman custom...

Страница 15: ...ative main jet and installation instructions can be obtained by contacting Customer Support NOTICE Operation using an alternative main jet at elevations lower than the recommended minimum altitude can...

Страница 16: ...2 Move portable generator outdoors to safe operating location at least 20 feet from any occupied spaces 15 OPERATION 3 Disconnect all electrical loads from the generator Never start or stop the gener...

Страница 17: ...elease 10 Do not over choke As soon as engine starts and warms up move the choke lever to the RUN position 11 Push and release the START button on the remote control 3 to 5 seconds and start The gener...

Страница 18: ...ircuit breaker on control panel is in the closed on position 2 Start the generator with no electrical load attached 3 Allow the engine to run for several minutes to stabilize 4 Plug in and turn on the...

Страница 19: ...generator 18 OPERATION 3 Electric Start and Recoil Start Operations Flip the engine switch to OFF O position The battery switch always should be in OFF O position at the end of use to prevent battery...

Страница 20: ...English Customer Service 1 844 FIRMAN1 19 OPERATION 5 Turn the fuel valve to the OFF O position If a cover is used do not install until unit has cooled...

Страница 21: ...he spark plug and replace the air filter New spark plug and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable...

Страница 22: ...olonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REAC...

Страница 23: ...a clean cloth b Saturate foam air filter element with clean engine oil and squeeze in a clean cloth to remove excess oil Spark Plug Maintenance Changing the spark plug will help your engine start easi...

Страница 24: ...0 15 mm 0 004 0 006 in 0 10 0 15 mm Muffler and Spark Arrester WARNING Contact with muffler area could cause burns resulting in serious injury Do not touch hot parts It is a violation of California Pu...

Страница 25: ...rrester in the muffler and attach with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Make certain that the portable gene...

Страница 26: ...Cover the post with boots 9 Install the spark plug wire onto spark plug A M6X12 Battery Charging The battery powers the starter motor and control module This portable generator is equipped with an aut...

Страница 27: ...wn 3 There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained tur...

Страница 28: ...ill fuel tank with gasoline 4 Drain fuel tank and carburetor fill with fresh gasoline 5 Connect wire to spark plug 6 Replace spark plug 7 Drain gas tank and carburetor fill with fresh gasoline 8 Wait...

Страница 29: ...gle Cylinder 4 Stroke OHV Air Cooled 223cc Breakless Ignition Type Flywheel Magneto Unleaded Automotive Gasoline 6 U S Gallons 23L 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethan...

Страница 30: ...29 30 31 32 33 34 35 36 37 37 1 37 2 37 3 37 4 38 39 40 40 1 40 2 40 3 40 4 40 5 41 42 44 45 46 47 48 49 49 1 49 2 49 3 49 5 49 6 49 7 50 51 52 49 4 53 54 55 56 57 58 59 60 61 62 63 64 64 2 64 1 64 3...

Страница 31: ...3 97 1 97 2 1 2 2 1 2 2 2 3 2 4 4 3 5 7 8 6 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 26 27 28 29 25 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 6...

Страница 32: ...340723001 330713509 FIRMAN 223cc Engine Rubber Cap 2 Rubber Cap1 Alternator Assy Rotor Assy Stator Assy Stator Cover Generator End Cover Flange Bolt M5 12 Flange Bolt M8 252 Ground Wire Flange Bolt M6...

Страница 33: ...3581 336713582 336713660 336713614 336713620 336713619 336718350 336713586 340718305 336713564 329713608 Clamp 8 6 Pipe Clip 8 7 8 Remote Holder Remote Control Adapter Holder Socket Waterproof Cover P...

Страница 34: ...Bolt governor Arm Spring governor Rod Governor Control Assembly Flange Bolt M6 12 Breather Tube Stud Intake Gasket Inlet Plate Carburetor Insulator Gasket Carburetor Carburetor Gasket Air Cleaner Ste...

Страница 35: ...English Customer Service 1 844 FIRMAN1 34 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Страница 36: ...future reference Repairs or replacements without prior authorization or at an unauthorized repair facility will not be covered by this warranty Normal Wear Your product needs periodic parts and servic...

Страница 37: ...ct Information You may contact FIRMAN at Address Firman Power Equipment Inc Attn Customer Service 8716 W Ludlow Dr Suite 6 www firmanpowerequipment com Peoria AZ 85381 We are FIRMAN POWER And we are h...

Страница 38: ...a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part o...

Страница 39: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Страница 40: ...l rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT INC PEORIA AZ 85381 1 844 347 6261 WWW FIRMANPOWEREQUIPMENT COM 87...

Отзывы: