Problem

Cause

Correction

Engine

 

is

 

running

but

 

no

 

AC

 

output

 

is

 

available

.

1

Circuit

 

breaker

 

is

 

open

.

2

Fault

 

in

 

generator

.

3

.

set

.

 

Poor

 

connection

 

or

 

defective

 

cord 

4

Connected

 

device

 

is

 

bad

.

1

Reset

 

circuit

 

breaker

.

2

Contact

 

authorized

 

service

 

facility

.

3

Check

 

and

 

repair

.

4

Connect

 

another

 

device

 

that

 

is

 

in

 

good

 

condition

.

Engine

 

runs

 

good

 

at

 

no

-

load

 

but

 “

bogs

 

down

” 

when

 

loads

 

are

 

connected

.

1

Short

 

circuit

 

in

 

a

 

connected

 

load

.

2

Engine

 

speed

 

is

 

too

 

slow

.

3

Shorted

 

generator

 

circuit

.

1

Disconnect

 

shorted

 

electrical

 

load

.

2

Contact

 

authorized

 

service

 

facility

.

3

Contact

 

authorized

 

service

 

facility

.

Engine

 

will

 

not

 

start

starts

 

and

 

runs

 

rough

 

or

 

shuts

 

down

 

when

 

running

.

1. Low

 

oil

 

level

.

 

2. Dirty

 

air

 

cleaner

.

3. Out

 

of

 

gasoline

.

4. Stale

 

gasoline

.

 

5. Spark

 

plug

 

wire

 

not

 

connected

 

to

 

spark

 

plug

.

6. Bad

 

spark

 

plug

.

7. Water

 

in

 

gasoline

.

 

8. Flooded

.

 

9. Excessively

 

rich

 

fuel

 

mixture

.

1.

 

Fill

 

crankcase

 

to

 

proper

 

level

 

or

 

place

 

generator

 

on

 

level

 

surface

.

2

Clean

 

or

 

replace

 

air

 

cleaner

.

3

Fill

 

fuel

 

tank with gasoline

.

4

 

Drain

 

fuel

 

tank

 

and

 

carburetor

fill

 

with

 

fresh

 

gasoline

.

5

Connect

 

wire

 

to

 

spark

 

plug

.

6

Replace

 

spark

 

plug

.

7.

 

Drain

 

gas

 

tank

 

and

 

carburetor

fill

 

with

 

fresh

 

gasoline

.

   

Wait

 5 

minutes

 

and

 

re

-

crank

 

engine

.

8.
9.

 

Contact

 

authorized

 

service

 

facility

.

Engine

 

lacks

 

power

.

1

Load

 

is

 

too

 

high

.

2

Dirty

 

air

 

filter

.

1. Don't

 

Overload

 

Generator

2.

 Replace

 

air

 

filter

.

Engine

hunts

or

 

falters

.

1. Carburetor

 

is

 

running

 

too

 

rich

 

or

 

too lean

.

1. Contact

 

authorized

 

service

 

facility

.

10. Clogged or dirty fuel filter.

4. Clean or replace fuel filter.

10. Clean or replace fuel filter.

3. Clogged or dirty fuel filter.
4. Clogged spark arrester.

3. Clean or replace fuel filter.

4. Clean or replace spark arrester.

2. Clogged or dirty fuel filter.

2. Clean or replace fuel filter.

Engine shuts down when 
running.

1. Out of gasoline.

2. Dirty air cleaner.

3. Low oil level.

1. Fill fuel tank with gasoline.

2. Clean or replace air cleaner.

3. Fill crankcase to proper level or place. 

    generator on level surface.

4. Clogged or dirty fuel filter.

For all other issues, contact authorized dealer or Firman customer service.

27

Engine shuts down and 

yellow CO fault light blinking.

1. CO system fault

1. Contact authorized FIRMAN 
    service facility.

Содержание P03634

Страница 1: ...P N 336735501 Rev 00 OPERATOR S MANUAL GASOLINE PORTABLE GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER P03634 Rev Level 00...

Страница 2: ...pport This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for suppl...

Страница 3: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Страница 4: ...rminals on the AC output receptacles The system ground is connected to the AC neutral wire The neutral is bonded to the generator frame System Ground There may be Federal or State regulations local co...

Страница 5: ...gnizes that this increases the risk of CO poisoning to people inside the home and assumes that risk DANGER Engine exhaust contains carbon monoxide a poisonous gas that will kill you in minutes You can...

Страница 6: ...mage on this page 05 FEATURES AND CONTROLS 1 Fuel Gauge 2 5 0 Gallon 19L Capacity Fuel Tank 3 Fuel Cap 5 Fuel Valve 6 Air Filter 7 208cc FIRMAN OHV Engine 8 Recoil Starter 9 Bottle Opener 10 11 12 13...

Страница 7: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS...

Страница 8: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS...

Страница 9: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS...

Страница 10: ...uit protectors If the generator is overloaded or an external short circuit occurs a circuit protector may trip If tripping occurs disconnect all electrical loads and determine the cause before attempt...

Страница 11: ...crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even...

Страница 12: ...able generator at least 5 ft 1 5 m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator in...

Страница 13: ...art to select the proper oil for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oi...

Страница 14: ...enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact Firman custom...

Страница 15: ...ative main jet and installation instructions can be obtained by contacting Customer Support NOTICE Operation using an alternative main jet at elevations lower than the recommended minimum altitude can...

Страница 16: ...fuel cap and air cleaner are all in place 2 Move portable generator outdoors to safe operating location at least 20 feet from any occupied spaces 15 OPERATION 3 Disconnect all electrical loads from th...

Страница 17: ...ectrical devices NOTICE If engine starts but fails to run or if portable generator shuts down during operation check oil level See Low Oil Shutdown section for more information 7 Pull the starter cord...

Страница 18: ...IRMAN customer service If GFCI trips while in use reset and test the outlet Electric cords laying on the ground with worn insulation may trip the GFCI only use cords in good condition RESET TEST TEST...

Страница 19: ...oltage fluctuations While there is no way to prevent all voltage fluctuations you can take steps to protect your sensitive electronic equipment Install a plug in surge suppressor on the receptacles fe...

Страница 20: ...e FIRMAN authorized service dealer Yellow light will blink for five seconds at the startup of generator to show CO ALERT is functioning properly TM Carbon monoxide accumulated around generator Prior t...

Страница 21: ...stop the engine by moving the choke to the start position Let the generator run at no load for one minute to stabilize internal temperatures of the engine and generator 20 OPERATION 2 Flip the engine...

Страница 22: ...he spark plug and replace the air filter New spark plug and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable...

Страница 23: ...olonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REAC...

Страница 24: ...a clean cloth b Saturate foam air filter element with clean engine oil and squeeze in a clean cloth to remove excess oil Spark Plug Maintenance Changing the spark plug will help your engine start easi...

Страница 25: ...n 0 10 0 15 mm 0 004 0 006 in 0 10 0 15 mm Muffler and Spark Arrester WARNING Contact with muffler area could cause burns resulting in serious injury Do not tough hot parts It is a violation of Califo...

Страница 26: ...ester in the muffler and attach with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Make certain that the portable genera...

Страница 27: ...wn 3 There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained tur...

Страница 28: ...air cleaner 3 Fill fuel tank with gasoline 4 Drain fuel tank and carburetor fill with fresh gasoline 5 Connect wire to spark plug 6 Replace spark plug 7 Drain gas tank and carburetor fill with fresh...

Страница 29: ...e Flywheel Magneto Unleaded Automotive Gasoline 5 U S Gallons 19L 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4550 FIRMAN Rated Fequency 60Hz Oil Type See Add Engin...

Страница 30: ...PARTS DIAGRAM AND PART LIST P03634 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 29 104...

Страница 31: ...208cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 30...

Страница 32: ...8 Bracket Handle Pin Handle Handle Nut M8 Cover Handle Flange Bolt M8 16 Support Leg Assy 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 2 1 2 1 4 1 1 1 3 1 1 3 1 2 1 1 5 1 2 2 2 1 1 2 1 1 1 1 1 1 2 1 2 1 NO Part Nu...

Страница 33: ...1 1 4 1 1 1 8 1 1 2 1 1 1 2 2 1 1 1 1 1 English Customer Service 1 844 FIRMAN1 32 Parts Diagrams Parts Lists Wiring Diagram NO Part Number Description Qty Switch Cover Circuit Breaker Cover Circuit Br...

Страница 34: ...rn Cord Pulley Recoil Starter Spring Patchet Patchet Starter Clip Sprg Pawl Guide Pawl Guide Screw Pawl Guide Locknut Pulley Starter Protect Circle Flange Bolt M6 12 Fan Cover Comp Wind Deflectors Bol...

Страница 35: ...English Customer Service 1 844 FIRMAN1 34 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Страница 36: ...for commercial industrial use Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser This warranty only applies to the o...

Страница 37: ...ct Information You may contact FIRMAN at Address FIRMAN Power Equipment Inc Attn Customer Service 8716 W Ludlow Dr Suite 6 www firmanpowerequipment com Peoria AZ 85381 We are FIRMAN POWER And we are h...

Страница 38: ...a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part o...

Страница 39: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Страница 40: ...reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT INC 8716 W LUDLOW DR SUITE 6 PEORIA AZ 85381 1 844 347 6261 WWW FIRMANPOWEREQUIPMENT CO...

Отзывы: