Page 04

WHEN OPERATING EQUIPMENT

DO NOT

 tip engine or equipment at angle 

which causes fuel to spill.

DO NOT

 stop engine by moving choke 

control to “Start” position. 

WHEN TRANSPORTING, MOVING 
OR REPAIRING EQUIPMENT

Transport/move/repair with fuel tank 
EMPTY or with fuel shutoff valve OFF.

DO NOT

 tip engine or equipment at angle 

which causes fuel to spill.
Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT 
WITH FUEL IN TANK

WARNING


WARNING

Generator voltage could cause 
electrical shock or burn resulting 
in death or serious injury.

WARNING


NEVER

 start or stop engine with electrical 

devices plugged in and turned on.

WARNING

 

Fuel and its vapors are extremely flammable 
and explosive which could cause burns, fire, 
or explosion resulting in death or serious 
injury and/or property damage.

WHEN ADDING OR DRAINING FUEL

Turn generator engine OFF and let it cool at 
least 2 minutes before removing fuel cap. 
Loosen cap slowly to relieve pressure in tank.
Fill or drain fuel tank outdoors.

DO NOT

 overfill tank. Allow space for fuel 

expansion.

If fuel spills, wait until it evaporates before 
starting engine.

Keep fuel away from sparks, open flames, 
pilot lights, heat, and other ignition sources.

Check fuel lines, tank, cap, and fittings 
frequently for cracks or leaks. Replace if 
necessary.

DO NOT

 light a cigarette or smoke.


WHEN STARTING EQUIPMENT

Ensure spark plug, muffler, fuel cap, and air 
cleaner are in place.

DO NOT

 crank engine with spark plug 

removed.

Use approved transfer equipment, suitable 
for the intended use, to prevent backfeed by 
isolating generator from electric utility 
workers.

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

Содержание P03617

Страница 1: ...lly before operating equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Serial Number MODEL NUMBER P03617 Rev Level 01 DO NOT RETURN TO STORE CALL US F...

Страница 2: ...erator Electric Start 20 Starting the Generator Remote Start 21 Connecting Electrical Loads 22 Stopping the Engine 22 Low Oil Shutdown 24 Do Not Overload Generator 24 Introduction Battery Cable Connec...

Страница 3: ...mation The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all...

Страница 4: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD English Customer Service 1 844 FIRMAN1...

Страница 5: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Страница 6: ...ns fire or explosion resulting in death or serious injury and or property damage WHEN ADDING OR DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loos...

Страница 7: ...T handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING Exhaus...

Страница 8: ...n your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency NO...

Страница 9: ...following instructions and pictures to remove the attached engine support brackets red under the engine 3 You may discard these brackets as it is no longer required for normal operation of your gener...

Страница 10: ...embly prior to usage If problem arise when assembling the generator call 1 844 347 6261 H K 1 Before adding wheels tip the generator on its side 2 Slide the axle pin A through the wheel B 3 Slide the...

Страница 11: ...nection NOTE The generator comes equiped with the positive red and negative black cables already attached to battery terminals 1 Cut wire tie that is binding the black battery cables A and B 2 Insert...

Страница 12: ...Cap 12 Easy Oil Drain 17 Remote Holder Includes Remote English Customer Service 1 844 FIRMAN1 We are always working to improve our products Therefore the enclosed product may differ slightly from the...

Страница 13: ...pt to start When the engine starts release the switch to the RUN l position 1 Control Panel A Digital display B AC voltage indicator C Frequency indicator D Hour indicator E Low oil indicator F Select...

Страница 14: ...stomer Service 1 844 FIRMAN1 16 Your remote control is already programmed in factory for your convenience You might need programming when using new remote control 17 Tethered Adapter TT 30P 30A 120V t...

Страница 15: ...STOP 5 Push and release the START button The indicator light will flash once to program the remote START 6 Push and hold the program button approximately 3 seconds until the indicator light turn off...

Страница 16: ...er Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4550 FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section Grounding System AN IMPORTANT MESSAGE ABOUT TEMPERATURE When operated...

Страница 17: ...activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an eve...

Страница 18: ...k Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or wipe up any sp...

Страница 19: ...erwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqual...

Страница 20: ...the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may impair the prop...

Страница 21: ...ARNING When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 8 Pull the starter cord slowly until resistance...

Страница 22: ...evel and fuel 3 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plugged in or turned on 4 Turn the fuel valve to the ON l position 5 Flip t...

Страница 23: ...e remote control is replaced then you will need to go through programming procedure in Remote Control Programming section 3 Disconnect all electrical loads from the generator Never start or stop the g...

Страница 24: ...of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle Do not apply heavy electrical load during break in period the first five hours of oper...

Страница 25: ...will not give the battery a boost of power The Vehicle or the generator may be damaged Your generator has the capability of charging 12V DC automotive or utility style storage battery NOT OTHER TYPE...

Страница 26: ...damage DO NOT stop engine by moving choke control to START position Important Always ensure that the Fuel Valve and the Engine Switch are in the OFF position when the engine is not in use If the engi...

Страница 27: ...d replace the air filter New spark plugs and clean air filter assure proper fuel air mixture and help your engine run better and last longer English Customer Service 1 844 FIRMAN1 ITEM NOTES Daily Bef...

Страница 28: ...a new engine change oil after 25 hours Please use a container to dump the used oil for protecting the environment Maintaining an air filter in proper condition is very important Dirt induced through i...

Страница 29: ...ark plug using provided wrench Inspect spark plug for damage and clean with a wire brush before reinstalling Inspect Muffler and Spark Arrester Inspect the muffler for cracks corrosion or other damage...

Страница 30: ...erior surfaces of the generator Use a soft bristle brush to remove dirt and oil Use an air compressor 25 PSI to clear dirt and debris from the generator Inspect all air vents and cooling slots to ensu...

Страница 31: ...sential fuel system parts such as the carburetor fuel hoses or tank during storage Also experience indicates that alcohol blended fuels called gasohol ethanol or methanol can attract moisture which le...

Страница 32: ...s using a fuel stabilizer A FUEL STABLIZER will minimize the formula tion of fuel gum deposits during storage the fuel stabilizer can be added to the gasoline in the fuel tank or into the gasoline in...

Страница 33: ...ngine hunts or falters 1 Fill crankcase to proper level Place generator on level surface 2 Fill fuel tank with gasoline 3 Replace spark plug 4 Connect wire to spark plug 5 Clean or replace the fuel fi...

Страница 34: ...Page 32 PARTS DIAGRAM AND PART LIST P03617 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 137...

Страница 35: ...Page 33 208cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1...

Страница 36: ...sher Assemblies Generator End Cover Cap Ground Wire 2 Terminal Block Bolt washer Assemblies Carbon Brush Holder Carbon Brush Assembly Air Cleaner Bracket Flange Bolt M6 8 Muffler Fixed Plate A small M...

Страница 37: ...mbly Lifter Stopper Spring Throttle Valve Returning 1 2 1 8 1 2 1 1 1 1 1 1 1 2 6 1 2 1 1 1 1 1 2 1 1 1 7 4 2 2 1 2 1 1 1 2 2 2 1 2 1 1 1 2 2 2 1 2 1 2 1 1 1 1 2 3 1 1 4 1 61 62 63 64 65 66 67 68 69 7...

Страница 38: ...zed repair facility will not be covered by this warranty Normal Wear Your product needs periodic parts and service to perform well This warranty does not cover repair when normal use has exhausted the...

Страница 39: ...f God and other force majeure events beyond the manufacturer s control problems caused by parts that are not original FIRMAN parts units used for prime power in place of existing utility power where u...

Страница 40: ...failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part on y...

Страница 41: ...ld Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting clamps FI...

Страница 42: ...P N 336745464 Rev 04 Firman Power Equipment Inc Peoria AZ 85381 www firmanpowerequipment com 8716 West Ludlow Dr Suite 6...

Отзывы: