Firman P03612 Скачать руководство пользователя страница 14

Page 12

Remote

 

Start

This generator is equipped with a wireless remote
start system for starting and stopping.

The  Remote  Start  functions  are  enabled  when:
1.The Engine Switch is in the “

RUN

”(

l

) position, AND

2.The  Battery  Switch  is  in  the  “

ON

”(

l

)  position.

The  Remote  Start  functions  are  disabled  if  either
of the above conditions is not met.

Remote Control Power Consumption

While  the  Engine  Switch  is  in  the  “

RUN

”(

l

)

position  and  Battery  Switch  is  in  the  “

ON

”(

l

)

position,  the  remote  module  is  active  and
waiting  for  a  remote  signal.  This  function
requires  electrical  current  from  the  battery.
If  the  Battery  Switch  is  left  in  the  “

ON

”(

l

)

position for extended periods (several weeks),
the  battery  can  be  completely  drained.

THE BATTERY SWITCH ALWAYS SHOULD BE IN
"

OFF

"(

O

)  POSITION  AT  THE  END  OF  USE  TO

PREVENT BATTERY DRAIN.

NOTE:

             

Remote Control Programming

1. Flip the engine switch to the "

RUN

"(

l

) position.

2. Flip the battery switch to the "

ON

"(

l

) position.

3. Push  and  hold  the  program  button  on  the
control panel for approximately 3 seconds. The
remote start indicator light will light.

4. Push and release the ''

STOP

'' button on the

remote control. The indicator light will flash
once to erase the remote program.

STOP

5. Push and release the ''

START

'' button. The

indicator light will flash once to program the
remote.

START

6. Push and hold the program button approximately
3  seconds  until  the  indicator  light  turn  off.  The
generator is now programmed to start remotely.

NOTE: 

YOUR REMOTE CONTROL IS ALREADY PROGRAMMED IN
FACTORY FOR YOUR CONVENIENCE. AND IT IS READY TO
START THE GENERATOR.

Before the generator can be started , an initial
start-up procedure must be performed so the
generator  and  the  remote  control  recognize
each other.

If the remote control is replaced then you will
need to go through following procedure with
new remote control.

Indicator

Light

Program Button

Содержание P03612

Страница 1: ...operating equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverag...

Страница 2: ...r Recoil Start 18 Starting the Generator Electric Start 19 Starting the Generator Remote Start 20 Connecting Electrical Loads 21 Stopping the Engine 21 Low Oil Shutdown 22 Do Not Overload Generator 22...

Страница 3: ...ortant Safety Information The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit ar...

Страница 4: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD WARNING WARNING...

Страница 5: ...ning ONLY use outside and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window...

Страница 6: ...hich could cause burns fire or explosion resulting in death or serious injury and or property damage WHEN ADDING OR DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before re...

Страница 7: ...or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service gene...

Страница 8: ...this product to power medical devices or medical appliances Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live Inform your electri...

Страница 9: ...arranty Refer to the following instructions and pictures to remove the attached engine support brackets red under the engine 3 You may discard these brackets as it is no longer required for normal ope...

Страница 10: ...The generator requires some assembly prior to usage Install the Wheel Kit H K 1 Before adding wheels tip the generator on its side 2 Slide the axle pin A through the wheel B 3 Slide the axle pin A thr...

Страница 11: ...ive battery cable red boot is securely tightened to the positive battery post Make sure boot is over battery post 2 Remove bolt M5X10 and M5 nut from black cable ring 3 Remove vinyl cap from the negat...

Страница 12: ...IRMAN OHV Engine 8 Recoil Starter 9 Bottle Opener 10 Remote Holder We are always working to improve our products Therefore the enclosed product may differ slightly from the image on this page 1 2 The...

Страница 13: ...l receptacles must not exceed the name plate rating Engine Start Switch Used to start engine from the starter motor Electric start model only To start engine press and hold the switch in the START ll...

Страница 14: ...Control Programming 1 Flip the engine switch to the RUN l position 2 Flip the battery switch to the ON l position 3 Push and hold the program button on the control panel for approximately 3 seconds T...

Страница 15: ...o Unleaded Automotive Gasoline 5 0 Gallon 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4550 FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section AN IMPORTA...

Страница 16: ...ired the sensor will activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to...

Страница 17: ...ed fuel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engin...

Страница 18: ...T operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or chi...

Страница 19: ...and protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation...

Страница 20: ...NG When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 8 Pull the starter cord slowly until resistance is...

Страница 21: ...and fuel 3 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plugged in or turned on 4 Turn the fuel valve to the ON l position 5 Flip the en...

Страница 22: ...READYTO STARTTHEGENERATOR If the remote control is replaced then you will need to go through programming procedure in Remote Control Programming section 3 Disconnect all electrical loads from the gene...

Страница 23: ...ol panel is in on position This unit has been pretested and adjusted to handle its full capacity Before starting the generator disconnect all load Apply load only after generator is running Voltage is...

Страница 24: ...lease see the Storage section for proper engine and fuel storage Low Oil Shutdown If the engine oil drops below a preset level an oil switch will stop the engine Check oil level with dipstick If oil l...

Страница 25: ...attached devices follow these steps to add electrical load 1 Start the generator with no electrical load attached 2 Allow the engine to run for several minutes to stabilize 3 Plug in and turn on the...

Страница 26: ...commendations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been s...

Страница 27: ...in certain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hour...

Страница 28: ...d strainer cup with gasoline c Tightly fasten the cup to main body making sure to avoid fuel leak SCREEN O ring CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and cle...

Страница 29: ...cloth to clean exterior surfaces of the generator Use a soft bristle brush to remove dirt and oil Use an air compressor 25 PSI to clear dirt and debris from the generator Inspect all air vents and co...

Страница 30: ...parts such as the carburetor fuel hoses or tank during storage Also experience indicates that alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation a...

Страница 31: ...lizer A FUEL STABLIZER will minimize the formula tion of fuel gum deposits during storage the fuel stabilizer can be added to the gasoline in the fuel tank or into the gasoline in a storage container...

Страница 32: ...l tank 6 Drain fuel tank and carburetor fill with fresh fuel 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh fuel 10 Wait 5 minutes and re crank engin...

Страница 33: ...Page 30 PARTS DIAGRAM AND PART LIST P03612 PARTS DIAGRAM...

Страница 34: ...Page 31 208cc ENGINE PARTS DIAGRAM...

Страница 35: ...play Fuel Filter Wire Mesh Fuel Cap Hose Fuel Fuel Valve Guard Muff Frame Axle Pin Wheel Cotter Pin Rubber Support Nut M8 Flange Bolt M8 16 61 62 63 64 65 66 68 69 71 72 73 74 75 76 77 78 79 80 81 82...

Страница 36: ...Carburetor Gasket Air Cleaner Nut M6 Elbow Air Cleaner Clapboard Cover Subassembly Cylinder Head Gasket Cylinder Head Cover Plate Subassembly Lifter Stopper Head Subassembly Cylinder NO Part Number De...

Отзывы: