WARNING

Page 05

Starter cord kickback (rapid retraction) will pull hand and arm toward 
engine faster than you can let go which could cause broken bones, 
fractures, bruises, or sprains resulting in serious injury.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to 
avoid kickback.

NEVER

 start or stop engine with electrical devices plugged in and turned on.

WARNING

 

Fuel and its vapors are extremely flammable and explosive 
which could cause burns, fire, or explosion resulting in death 
or serious injury.

WHEN ADDING OR DRAINING FUEL

Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap. 
Loosen cap slowly to relieve pressure in tank.• Fill or drain fuel tank outdoors.

DO NOT

 overfill tank. Allow space for fuel expansion

If fuel spills, wait until it evaporates before starting engine.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

Check fuel lines, tank, cap, and fittings frequently for cracks or leaks. Replace if 
necessary.

DO NOT

 light a cigarette or smoke.

WHEN STARTING EQUIPMENT

Ensure spark plug, muffler, fuel cap, and air cleaner are in place.

DO NOT

 crank engine with spark plug removed.

WHEN OPERATING EQUIPMENT

DO NOT

 operate this product inside any building, carport, porch, mobile equipment, 

marine applications, or enclosure.

DO NOT

 tip engine or equipment at angle which causes fuel to spill.

DO NOT

 stop engine by moving choke control to “Choke” position (      )

WHEN TRANSPORTING, MOVING OR REPAIRING EQUIPMENT

Transport/move/repair with fuel tank EMPTY or with fuel shutoff valve OFF.

DO NOT

 tip engine or equipment at angle which causes fuel to spill.

Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

Store away from furnaces, stoves, water heaters, clothes dryers, or other appliances 
that have pilot light or other ignition source because they could ignite fuel vapors.

Содержание ECO4000

Страница 1: ...and instructions carefully before operating equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering pa...

Страница 2: ...e not followed Indicates a possibility of personal injury or equipment damage if instructions are not followed Gives helpful information If a problem should arise or if you have any questions about th...

Страница 3: ...ed to proper oil level See Add Engine Oil Fuel tank filled at or below baffle See Add Fuel Inspect fuel lines tank cap and fittings each time before using generator DO NOT use if fuel leak or damage i...

Страница 4: ...ECIFICATIONS 08 3 COMPONENTS 11 4 PRE OPERATION CHECKS 12 5 OPERATING PROCEDURES 16 6 SERVICING THE GENERATOR 20 7 HOW TO MAINTENANCE 21 8 PREPARATION FOR STORAGE 24 9 TROUBLE SHOOTING 25 10 WARRANTY...

Страница 5: ...de alarms or plug in carbon monoxide alarms with battery back up according to the manufacturer s instructions Smoke alarms cannot detect carbon monoxide gas DO NOT run this product inside homes garage...

Страница 6: ...e Keep fuel away from sparks open flames pilot lights heat and other ignition sources Check fuel lines tank cap and fittings frequently for cracks or leaks Replace if necessary DO NOT light a cigarett...

Страница 7: ...water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING Exhaust heat gases could ignite combustibles structures or dama...

Страница 8: ...speeds impose a heavy load DO NOT tamper with governor spring links or other parts to increase engine speed Generator supplies correct rated frequency and voltage when running at governed speed DO NOT...

Страница 9: ...m output Ignition System Starting System Fuel Capacity Fuel Tank 193cc Breakless Ignition Type Flywheel Magneto Unleaded Automotive Gasoline Recoil 4 Gallon 21 oz Lubricating Oil Capacity Counter Cloc...

Страница 10: ...acement Maximum output Ignition System Starting System Fuel Capacity Fuel Tank 389cc Breakless Ignition Type Flywheel Magneto Unleaded Automotive Gasoline Recoil 7 Gallon 38 oz Lubricating Oil Capacit...

Страница 11: ...gnition System Starting System Fuel Capacity Fuel Tank 439cc Breakless Ignition Type Flywheel Magneto Unleaded Automotive Gasoline Recoil 7 Gallon 32 oz Lubricating Oil Capacity Counter Clockwise Faci...

Страница 12: ...ENGINE SWITCH 6 FUEL VALVE 7 CHOKE LEVER 8 RECOIL STARTER 9 OIL DRAIN PLUG 10 OIL FILLER CAP 11 GROUND TERMINAL 12 AIR CLEANER 13 SUPPORTING LEGS 14 MUFFLER 15 FUEL TANK 16 HANDLE FRAME 17 WHEELS 3 CO...

Страница 13: ...the following tools to install the wheels 21mm wrench or adjustable wrench not included Socket wrench with a 13mm socket not included Pliers not included 1 Before adding fuel and oil tip the generato...

Страница 14: ...NTENANCE If oil level is below the lower level line refill with suitable oil see table below to upper level line Do not screw in the oil filler cap when checking oil level Multigrade Ambient 20 10 0 1...

Страница 15: ...se fuel lever before refueling with fuel Be careful not to admit dust dirt water or other foreign objects into fuel Wipe off spilt fuel thoroughly before starting engine Keep away from open flames Be...

Страница 16: ...t block generator air vents with paper or other material Page 15 WARNING Move the generator to the desired location The generator is very easy to move take the handle up and then use your leg to make...

Страница 17: ...n the fuel switch c Set the choke lever to the START arrow mark position Not necessary if the engine is warm Page 16 d Turn the engine switch to the START position and hold it there for 4 5 seconds or...

Страница 18: ...mperage This generator is thoroughly tested and adjusted in the factory If the generator does not produce the specified voltage consult your nearest FIRMAN Generator dealer Be sure that the total watt...

Страница 19: ...l Bulletin area of the FIRMAN internet site The part number and recommended minimum altitude for the application of the high altitude carburetor main jet is listed in the table below In order to selec...

Страница 20: ...power switch of the electric equipment or unplug the cord from receptacle of the generator b Allow the engine about 3 minutes to cool down at no load before stopping c Set the engine switch to OFF po...

Страница 21: ...control panel components Check rotor and stator Replace engine mount rubber Overhaul engine Change fuel lines 300 hours or every year 100 hours 50 hours Weekly Daily Servicing work should only be carr...

Страница 22: ...quality lubricating oil to the specified quantity If contaminated or deteriorated oil is used or the quantity of the engine oil is not sufficient the engine damage will result and its life will be gre...

Страница 23: ...ectrode gap to 0 7 to 0 8 mm 0 028 to 0 031 SPARK PLUG NGK BPR6HS equivalent Dirt and water in the fuel are removed by the fuel strainer a Remove the strainer cup and throw away water and dirt b Clean...

Страница 24: ...g in death or serious injury Contact with muffler area could cause burns resulting in serious injury Keep at least 5 feet 1 5 m of clearance on all sides of generator including overhead Contact the or...

Страница 25: ...rting difficult Loosen the drain screw on the bottom of the carburetor float chamber and drain the fuel completely Change engine oil Check for loose bolts and screws tighten them if necessary Clean ge...

Страница 26: ...lever is in OFF 0 position 3 Low oil level 4 Dirty air cleaner 5 Out of fuel 6 Stale fuel 7 Spark plug wire not connected to spark plug 8 Bad spark plug 9 Water in fuel 10 Flooded 11 Excessively rich...

Страница 27: ...AN will at its option authorize evaluation repair or replacement of the defective part or component at a FIRMAN Service Center FIRMAN will provide you with a case number for warranty service Please ke...

Страница 28: ...to the warranty of the original unit The length of the warranty governing the exchanged unit will remain calculated by reference to the purchase date of the original unit This warranty gives you certa...

Страница 29: ...P N 335735000 Rev 00 WWW FIRMANGENERATORS COM Toll Free 1 844 347 6261...

Отзывы: